Search NASA⌕ Search

SEARCH · Search NASA

Results for “Confocal microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Stomata in-sight: Integrating live confocal microscopy with leaf gas exchange and environmental control

Stomatal anatomy (aperture area, length, and width) influences leaf-level physiology traits including conductance to water vapor. Stomatal anatomy can be visualized in situ by microscopy, but the difficulty of regulating the atmospheric environment of a microscope stage means that the conditions under which imaging is done are rarely physiologically relevant. Alternatively, leaf gas exchange instruments that measure gas fluxes reflect stomatal anatomical characteristics in aggregate, but the relative strengths of anatomical traits to control water use (e.g. size vs density) cannot be firmly established. To reconcile the microscopic stomatal characteristics with leaf-level gas exchange, we describe a tool that combines laser scanning confocal microscopy, gas exchange instruments, and machine-learning image analysis to simultaneously observe anatomical characteristics of many (>40) stomata alongside leaf-level traits like photosynthesis, transpiration, and stomatal conductance. We demonstrate how the tool has the resolution capable of quantifying aperture sizes and variability in maize (Zea mays) leaves under 5 steady-state light/pCO 2 treatments while tightly controlling other environmental variables like relative humidity and temperature. A model used to calculate stomatal conductance from measured apertures and stomatal density accurately matched stomatal conductance measured by gas exchange. This technical advancement will provide insight on how stomatal anatomy and function trade off to influence stomatal conductance and leaf-level water use efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

Adapting confocal Raman microscopy for in situ studies of redox transformations at electrode-electrolyte interfaces

Confocal Raman microscopy was applied to quantify redox species present within the diffusion layer adjacent to an electrode surface under potentiostatic control. A glass microscope coverslip with a thin indium tin oxide (ITO) coating served as both the working electrode and optical window for a microscope-stage mountable spectroelectrochemical cell. A high numerical aperture objective mounted in an inverted microscope frame just below the stage brought excitation radiation through the coverslip window and to a tight focus a few micrometers above the ITO film surface. Species diffusing into the confocal probe volume defined by the excitation beam focus and the collected light region were detected, identified and quantified based on their Raman scattering frequencies and intensities. Here, in measurements that interrogated the interconversion of ferrocyanide and ferricyanide ions as a function of applied voltage, least-squares regression analysis of spectral datasets predicted the formal potential and relative surface concentrations of the ions in good agreement with the expected Nernstian response. Preliminary studies of methyl viologen reduction at an ITO film/Nafion membrane interface were conducted and show the possibility for estimation of mass transport coefficients of redox species within ionic polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

Correlative SIP-FISH-Raman-SEM-NanoSIMS links identity, morphology, biochemistry, and physiology of environmental microbes

Microscopic and spectroscopic techniques are commonly applied to study microbial cells but are typically used on separate samples, resulting in population-level datasets that are integrated across different cells with little spatial resolution. To address this shortcoming, we developed a workflow that correlates several microscopic and spectroscopic techniques to generate an in depth analysis of individual cells. By combining stable isotope probing (SIP), fluorescence in situ hybridization (FISH), scanning electron microscopy (SEM), confocal Raman microspectroscopy (Raman), and nano-scale secondary ion mass spectrometry (NanoSIMS), we illustrate how individual cells can be thoroughly interrogated to obtain information about their taxonomic identity, structure, physiology, and metabolic activity. Analysis of an artificial community demonstrated that our correlative approach was able to resolve the activity of single cells using heavy water SIP in conjunction with Raman and/or NanoSIMS and establish their taxonomy and morphology using FISH and SEM. We then applied this workflow to a sample of yet uncultured multicellular magnetotactic bacteria. In addition to establishing their identity and activity, backscatter electron microscopy (BSE), NanoSIMS, and energy-dispersive X-ray spectroscopy (EDS) were employed to characterize the magnetosomes within the cells. By integrating these techniques, we demonstrate a cohesive approach to thoroughly study environmental microbes at single cell resolution.

Schaible, George↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Connecting Femtosecond Transient Absorption Microscopy with Spatially Coregistered Time Averaged Optical Imaging Modalities

Multimodal all-optical imaging involving coregistered femtosecond transient absorption microscopy (TAM), time-integrated photoluminescence (PL), and steady-state modalities such as confocal reflectance and transmission offers an appealing approach to gain a comprehensive understanding of complex electronic excited-state phenomena in spatially heterogeneous systems. A unique combination of these modalities allows us to unravel not only the competing electronic excited-state dynamical processes but also the underlying morphological information with simultaneous high temporal and spatial resolution. However, correlating the various images obtained from time-resolved and time-independent modalities is generally nontrivial and particularly challenging when the electronic dynamics under study evolve in both time and space. Here, we demonstrate a new approach for rationally correlating time-resolved microscopy with coregistered time-integrated or steady-state modalities. Specifically, our approach involves an extended global lifetime analysis of the time-resolved microscopic data set to separate distinct dynamical processes taking place on commensurate time scales, and the resulting decay-associated amplitude maps (DAAMs) were applied to explore correlations with the images acquired using time-independent modalities. The feasibility of our approach was validated through analyzing a multimodal data set acquired from a thin film of chloride-containing mixed lead halide perovskites (CH 3 NH 3 PbI 3–x Cl x ) using femtosecond transient absorption, time-integrated PL, and confocal reflectance microscopies. Analysis of the results obtained enable us to gain new insight into the complex ultrafast relaxation dynamics in this highly heterogeneous system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Incremental Markings in the Sagittal Otolith of the Pacific Sardine ( Sardinops sagax ) Using Different Imaging Modalities

Teleost fish possess calcium carbonate otoliths located in separate chambers (utriculus, sacculus, and lagena) of their membranous labyrinth. This study analyzed the surface topography of the sagittal otolith of the Pacific sardine (Sardinops sagax) and the daily and annual increments in these otoliths. The otolith surface, characterized by laser scanning confocal microscopy for the first time, consisted of a system of prominent ridges and valleys (grooves), but it is unclear whether these structures are functional or represent time-resolving markings reflecting growth periodicity. Within the first-year volume, daily increments, each consisting of an incremental (more mineralized) and a discontinuous (less mineralized) zone, were resolved by optical microscopy and backscattered electron (BSE) imaging in the scanning electron microscope (SEM). Daily growth increments could, however, not be resolved in volumes formed after the first year, presumably because otolith growth markedly slows down and spacing of incremental markings narrows in older fish. Throughout otolith growth, the crystalline network continues across the discontinuous zones. Fluorochrome labeling provides additional information on growth after the first year. Compared with optical and BSE imaging, synchrotron microComputed Tomography of intact otoliths (with 0.69 µm volume elements) was less able to resolve daily increments; X-ray phase contrast reconstructions provided more detail than reconstructions with absorption contrast. Future research directions are proposed.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Diagnosis through AI-driven Analysis of Reflectance Confocal Microscopy

Reflectance Confocal Microscopy (RCM) is a non-invasive imaging technique used in biomedical research and clinical dermatology. It provides virtual high-resolution images of the skin and superficial tissues, reducing the need for physical biopsies. RCM employs a laser light source to illuminate the tissue, capturing the reflected light to generate detailed images of microscopic structures at various depths. Recent studies explored AI and machine learning, particularly CNNs, for analyzing RCM images. Our study proposes a segmentation strategy based on textural features to identify clinically significant regions, empowering dermatologists in effective image interpretation and boosting diagnostic confidence. This approach promises to advance dermatological diagnosis and treatment.

Yoon, Hong-Jun↗

Hybrid Unilamellar Vesicles of Phospholipids and Block Copolymers with Crystalline Domains

Phospholipid (PL) membranes are ubiquitous in nature and their phase behavior has been extensively studied. Lipids assemble in a variety of structures and external stimuli can activate a quick switch between them. Amphiphilic block copolymers (BCPs) can self-organize in analogous structures but are mechanically more robust and transformations are considerably slower. The combination of PL dynamical behavior with BCP chemical richness could lead to new materials for applications in bioinspired separation membranes and drug delivery. It is timely to underpin the phase behavior of these hybrid systems and a few recent studies have revealed that PL–BCP membranes display synergistic structural, phase-separation, and dynamical properties not seen in pure components. One example is phase-separation in the membrane plane, which seems to be strongly affected by the ability of the PL to form lamellar phases with ordered alkyl chains. In this paper we focus on a rather less explored design handle which is the crystalline properties of the BCP component. Using a combination of confocal laser scanning microscopy and X-ray scattering we show that hybrid membranes of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) and methoxy-poly(ethylene glycol)-b-poly(ε-caprolactone) (mPEG-b-PCL) display BCP-rich and PL-rich domains when the BCP comprises crystalline moieties. The packing of the hydrophilic part of the BCP (PEG) favors mixing of DPPC at the molecular level or into nanoscale domains while semi-crystalline and hydrophobic PCL moieties bolster microscopic domain formation in the hybrid membrane plane

phase-separation↗

Assembly of Building Blocks by Double-End-Anchored Polymers in the Dilute Regime Mediated by Hydrophobic Interactions at Controlled Distances

Hierarchical assembly of building blocks via competing, orthogonal interactions is a hallmark of many of nature’s composite materials that do not require highly specific ligand-receptor interactions. To mimic this assembly mechanism requires the development of building blocks capable of tunable interactions. In the present work, we explored the interplay between repulsive (steric and electrostatic) and attractive hydrophobic forces. The designed building blocks allow hydrophobic forces to effectively act at controlled, large distances, to create and tune the assembly of membrane-based building blocks under dilute conditions and affect their interactions with cellular membranes via physical cross-bridges. Specifically, we employed double-end-anchored poly(ethylene glycol)s (DEA-PEGs)—hydrophilic PEG tethers with hydrophobic tails on both ends. Using differential-interference-contrast optical microscopy, synchrotron small angle X-ray scattering (SAXS), and cryogenic electron microscopy, we investigated the ability of DEA-PEGs to mediate assembly in the dilute regime on multiple length scales and on practical time scales. The PEG length, anchor hydrophobicity, and molar fraction of DEA-PEG molecules within a membrane strongly affect the assembly properties. Additional tuning of the intermembrane interactions can be achieved by adding repulsive interactions via PEG-lipids (steric) or cationic lipids to the DEA-PEG-mediated attractions. Further, while the optical and electron microscope imaging methods provided qualitative evidence of the ability of DEA-PEGs to assemble liposomes, the SAXS measurements and quantitative line-shape analysis in dilute preparations demonstrated that the ensemble average of loosely organized liposomal assemblies maintains DEA-PEG concentration-dependent tethering on defined nanometer length scales. For cationic liposome–DNA nanoparticles (CL–DNA NPs), aggregation induced by DEA-PEGs decreased internalization of NPs by cells, but tuning the DEA-PEG-induced attractions by adding repulsive steric interactions via PEG-lipids limited aggregation and increased NP uptake. However, confocal microscopy imaging together with colocalization studies with Rab11 and LysoTracker as markers of intracellular pathways showed that modifying CL–DNA NPs with DEA-PEGs alters their interactions with the plasma and endosomal membranes.

- x-ray scattering↗

Microscopic Measurement: Need for Nuclear Material Sample Specimen Characterization Capability

The Surveillance, Fabrication, and Off-Site Operations team at Lawrence Livermore National Laboratory is beginning an update to the nuclear material machining lab in Superblock. Plutonium and other nuclear materials tend to accelerate the aging process for equipment and machines that would otherwise be maintainable for long lives. They have their lifespans shortened from deteriorated seals, embrittled polymer components, accelerated corrosion, and damage to electronics from exposure to radioactive materials. The cost of installation of equipment into a glove box (GB) tends to outstrip the cost of the equipment itself. Due to the magnification of cost, the historical approach to equipment installs has been to purchase and install the highest-quality and most robust equipment available to maximize time between failures and updates. To make room for the installation of a new lathe, the inspection GB is being moved to a different location within the machining lab. As part of the overall effort, the equipment within the inspection GB is being revisited. Current measurement capabilities are antiquated and starting to become problematic due to age. Advances in metrology are sought for more comprehensive characterization of scientific samples. This document aims to identify several options for the replacement of current measurement equipment and identify a system for purchase and eventual installation. The intention is not to select the cheapest system, but rather to identify a system that best meets the needs of both the operators and principal investigators (PI). Following the convention of the SYSM-5620 Design Thinking and System Engineering, it was determined that a laser confocal measurement system from Keyence is the most suitable option for our programmatic need. Form factor, capability, and maintainability were considered. Along with stakeholder input, to ensure the best decision for the Nuclear Material Technology Program.

36 MATERIALS SCIENCE↗