Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Practical Weak-lensing Shear Measurement with Metacalibration

Metacalibration is a recently introduced method to accurately measure weak gravitational lensing shear using only the available imaging data, without need for prior information about galaxy properties or calibration from simulations. The method involves distorting the image with a small known shear, and calculating the response of a shear estimator to that applied shear. The method was shown to be accurate in moderate-sized simulations with galaxy images that had relatively high signal-to-noise ratios, and without significant selection effects. In this work we introduce a formalism to correct for both shear response and selection biases. We also observe that for images with relatively low signal-to-noise ratios, the correlated noise that arises during the metacalibration process results in significant bias, for which we develop a simple empirical correction. To test this formalism, we created large image simulations based on both parametric models and real galaxy images, including tests with realistic point-spread functions. We varied the point-spread function ellipticity at the five-percent level. In each simulation we applied a small few-percent shear to the galaxy images. We introduced additional challenges that arise in real data, such as detection thresholds, stellar contamination, and missing data. We applied cuts on the measured galaxy properties to induce significant selection effects. Using our formalism, we recovered the input shear with an accuracy better than a part in a thousand in all cases.

79 ASTRONOMY AND ASTROPHYSICS↗

ECOLOGICAL EFFECTS OF METALS IN STREAMS ON A DEFENSE MATERIALS PROCESSING SITE IN SOUTH CAROLINA, USA

The Savannah River Site (SRS) is a 780 km{sup 2} U.S. Department of Energy facility near Aiken SC established in 1950 to produce nuclear materials. SRS streams are 'integrators' that potentially receive water transportable contaminants from all sources within their watersheds necessitating a GIS-based watershed approach to organize contaminant distribution data and accurately characterize the effects of multiple contaminant sources on aquatic organisms. Concentrations of metals in sediments, fish, and water were elevated in streams affected by SRS operations, but contaminant exposure models for Lontra Canadensis and Ceryle alcyon indicated that toxicological reference values were exceeded only by Hg and Al. Macroinvertebrate community structure was unrelated to sediment metal concentrations. This study indicated that (1) modeling studies and field bioassessments provide a complementary basis for addressing the individual and cumulative effects of contaminants, (2) habitat effects must be controlled when assessing contaminant impacts, (3) sensitivity analyses of contaminant exposure models are helpful in apportioning sampling effort, and (4) contaminants released during fifty years of industrial operations have not resulted in demonstrable harm to aquatic organisms in SRS streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of urinary excretion data from three plutonium-contaminated wounds at Los Alamos National Laboratory

The NCRP-156 Report proposes seven different biokinetic models for the wound cases depending on the physicochemistry of the contaminant. Because the models were heavily based on experimental animal data, the authors of the report encouraged application and validation of the models using bioassay data from actual human exposures. Each of the wound models was applied to three plutonium-contaminated wounds, and the models resulted in a good agreement to only one of the cases. We then applied a simpler biokinetic model structure to the bioassay data and showed that fitting the transfer rates from this model structure yielded better agreement with the data than does the best-fitting NCRP-156 model. Because the biokinetics of radioactive material in each wound is different, it is impractical to propose a discrete set of model parameters to describe the biokinetics of radionuclides in all wounds, and thus each wound should be treated empirically.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗

Unclassified Source Term and Radionuclide Data for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada, Revision 1

This report documents the evaluation of the information and data available on the unclassified source term and radionuclide contamination for CAU 97: Yucca Flat/Climax Mine. The total residual inventory of radionuclides associated with one or more tests is known as the radiologic source term (RST). The RST is comprised of radionuclides in water, glass, or other phases or mineralogic forms. The hydrologic source term (HST) of an underground nuclear test is the portion of the total RST that is released into the groundwater over time following the test. In this report, the HST represents radionuclide release some time after the explosion and does not include the rapidly evolving mechanical, thermal, and chemical processes during the explosion. The CAU 97: Yucca Flat/Climax Mine has many more detonations and a wider variety of settings to consider compared to other CAUs. For instance, the source term analysis and evaluation performed for CAUs 101 and 102: Central and Western Pahute Mesa and CAU 98: Frenchman Flat did not consider vadose zone attenuation because many detonations were located near or below the water table. However, the large number of Yucca Flat/Climax Mine tests and the location of many tests above the water table warrant a more robust analysis of the unsaturated zone.

54 ENVIRONMENTAL SCIENCES↗

A data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time-dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple mode

Accelerator Physics (physics.acc-ph)↗

Architecture of a Data Portal for Publishing and Delivering Open Data for Atmospheric Measurement

Atmospheric data are collected by researchers every day. Campaigns such as GOAmazon 2014/2015 and the Amazon Tall Tower Observatory collect essential data on aerosols, gases, cloud properties, and meteorological parameters in the Brazilian Amazon basin. These data products provide insights and essential information for analyzing and predicting natural processes. However, in Brazil, it is estimated that more than 80% of the scientific data collected are not published due to the lack of web portals that collect and store these data. This makes it difficult, or even impossible, to access and integrate the data, which can result in the loss of significant amounts of information and significantly affect the understanding of the overall data. To address this problem, we propose a data portal architecture and open data deployment that enable Big Data processing, human interaction, and download-oriented approaches with tools that help users catalog, publish and visualize atmospheric data. Thus, we describe the architecture developed, based on the experience of the Atmospheric Radiation Measurement Data Center, which incorporates the principles of FAIR, the infrastructure and content management system for managing scientific data. The portal partial results were tested with environmental data from contaminated areas at the University of São Paulo. Overall, this data portal creates more shared knowledge about atmospheric processes by providing users with access to open environmental data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Modeling and Quantitative Assessment of Green and Sustainable Remediation Options for the M1 Air Stripper System at DOE SRS - 15660

The effectiveness of remediation systems needs to be reviewed periodically to assess their performance over the years relative to efficiency and effectiveness. New technologies and Best Management Practices have emerged that can improve existing remediation systems. From a Green and Sustainable Remediation analysis, the higher energy and/or water usage of older systems might not be justified from an environmental protection rationale. For example, remediation systems can run intermittently and with slower flow rates, use less power, and still provide the required level of environmental remediation and protection. This research by the Applied Research Center at Florida International University (FIU) is the preliminary phase of a Green and Sustainable Remediation (GSR) analysis of the operations of the M1 air stripper and the A/M Area groundwater remediation system at the Savannah River Site (SRS). An initial baseline analysis has helped identify opportunities for implementing Green and Sustainable Remediation (GSR) practices while maintaining the hydraulic containment and effectiveness of the remediation system. This study included the collection of contaminant recovery data from SRS reports into a database of trichloroethene (TCE) and tetrachloroethene (PCE) removal from contaminant recovery wells RWM-1 through RWM-12. Presented below are data and preliminary findings from these recovery wells. Findings show that 7 of 12 recovery wells have transitioned to more PCE removal than TCE removal; the nearby steam injection remediation of 'Dynamic Underground Stripping' mobilized DNAPL and resulted in increased recovery in nearby wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Stochastic joint inversion of hydrogeophysical data for salt tracer test monitoring and hydraulic conductivity imaging

The assessment of hydraulic conductivity of heterogeneous aquifers is a difficult task using traditional hydrogeological methods (e.g., steady state or transient pumping tests) due to their low spatial resolution. Geophysical measurements performed at the ground surface and in boreholes provide additional information for increasing the resolution and accuracy of the inverted hydraulic conductivity field. We used a stochastic joint inversion of Direct Current (DC) resistivity and Self-Potential (SP) data plus in situ measurement of the salinity in a downstream well during a synthetic salt tracer experiment to reconstruct the hydraulic conductivity field between two wells. The pilot point parameterization was used to avoid over-parameterization of the inverse problem. Bounds on the model parameters were used to promote a consistent Markov chain Monte Carlo sampling of the model parameters. To evaluate the effectiveness of the joint inversion process, we compared 8 cases in which the geophysical data are coupled or not to the in situ sampling of the salinity to map the hydraulic conductivity. We first tested the effectiveness of the inversion of each type of data alone (concentration sampling, self-potential, and DC resistivity), and then we combined the data two by two. We finally combined all the data together to show the value of each type of geophysical data in the joint inversion process because of their different sensitivity map. We also investigated a case in which the data were contaminated with noise and the variogram unknown and inverted stochastically. The results of the inversion revealed that incorporating the self-potential data improves the estimate of hydraulic conductivity field especially when the self-potential data were combined to the salt concentration measurement in the second well or to the time-lapse cross-well electrical resistivity data. Various tests were also performed to quantify the uncertainty in the inverted hydraulic conductivity field.

54 ENVIRONMENTAL SCIENCES↗

The Underground Test Area Project of the Nevada Test Site: Building Confidence in Groundwater Flow and Transport Models at Pahute Mesa Through Focused Characterization Studies

Pahute Mesa at the Nevada Test Site contains about 8.0E+07 curies of radioactivity caused by underground nuclear testing. The Underground Test Area Subproject has entered Phase II of data acquisition, analysis, and modeling to determine the risk to receptors from radioactivity in the groundwater, establish a groundwater monitoring network, and provide regulatory closure. Evaluation of radionuclide contamination at Pahute Mesa is particularly difficult due to the complex stratigraphy and structure caused by multiple calderas in the Southwestern Nevada Volcanic Field and overprinting of Basin and Range faulting. Included in overall Phase II goals is the need to reduce the uncertainty and improve confidence in modeling results. New characterization efforts are underway, and results from the first year of a three-year well drilling plan are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

Hanford Site Tank 241-C-108 Residual Waste Contaminant Release Models and Supporting Data

This report presents the results of laboratory characterization, testing, and analysis for a composite sample (designated 20578) of residual waste collected from single-shell tank C-108 during the waste retrieval process after modified sluicing. These studies were completed to characterize concentration and form of contaminant of interest in the residual waste; assess the leachability of contaminants from the solids; and develop release models for contaminants of interest. Because modified sluicing did not achieve 99% removal of the waste, it is expected that additional retrieval processing will take place. As a result, the sample analyzed here is not expected to represent final retrieval sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Natural bacterial communities serve as quantitative geochemical biosensors

Biological sensors can be engineered to measure a wide range of environmental conditions. Here we show that statistical analysis of DNA from natural microbial communities can be used to accurately identify environmental contaminants, including uranium and nitrate at a nuclear waste site. In addition to contamination, sequence data from the 16S rRNA gene alone can quantitatively predict a rich catalogue of 26 geochemical features collected from 93 wells with highly differing geochemistry characteristics. We extend this approach to identify sites contaminated with hydrocarbons from the Deepwater Horizon oil spill, finding that altered bacterial communities encode a memory of prior contamination, even after the contaminants themselves have been fully degraded. We show that the bacterial strains that are most useful for detecting oil and uranium are known to interact with these substrates, indicating that this statistical approach uncovers ecologically meaningful interactions consistent with previous experimental observations. Future efforts should focus on evaluating the geographical generalizability of these associations. Taken as a whole, these results indicate that ubiquitous, natural bacterial communities can be used as in situ environmental sensors that respond to and capture perturbations caused by human impacts. These in situ biosensors rely on environmental selection rather than directed engineering, and so this approach could be rapidly deployed and scaled as sequencing technology continues to become faster, simpler, and less expensive. Here we show that DNA from natural bacterial communities can be used as a quantitative biosensor to accurately distinguish unpolluted sites from those contaminated with uranium, nitrate, or oil. These results indicate that bacterial communities can be used as environmental sensors that respond to and capture perturbations caused by human impacts.

54 ENVIRONMENTAL SCIENCES↗

Explicitly Accounting for Multiple Spatial Scales in Data Informing Kd Distribution Development - 18414

This work provides an example of incorporating information about spatial scale into input parameter distribution development for probabilistic performance assessment (PA) models and highlights the importance of having an interdisciplinary team working together in the distribution development process. The novel approach is demonstrated for contaminant partitioning coefficients for water/rock (Kds), providing a specific context for discussing the approach and challenges, but the strategy is general and applies to many other PA model inputs. In this example, a PA model of a radioactive waste disposal site is assumed to have large cells representing spatial scales of up to thousands of square meters in area and several to tens of meters in depth. Spatial variability in Kds is expected to occur at scales much smaller than the units in the model domain over which values are applied, and therefore values are intended to represent possible averages over the modeled volume (i.e., spatial scale represented by a PA model cell). Information about possible Kd values for each material category comes from a variety of literature sources, and the reported results used to inform the distribution are available at a wide range of scales (e.g., individual batch experiment results from small-scale samples, averages based on samples collected over site-scales, averages based on samples from large regions, etc.). Effectively addressing the mismatch in spatial scale between available information and the PA Model is a challenge within PA distribution development and it takes effort from database managers, subject matter experts, modelers, and statisticians. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process for Obtaining TI Waiver for Recalcitrant Radionuclides at DOE Sites - 18225

The current plan for treating radioactive iodine-129 ({sup 129}I) at the 200-UP-1 operable unit (OU) within the Central Plateau at the Hanford Site is to hydraulically contain the groundwater plume using injection wells placed at the leading edge of the plume. In the previous feasibility study for the OU, no treatment technologies were identified that could achieve the federal drinking water standard of 1 pCi/L. In addition to further study to identify viable remediation technology options, efforts were initiated to assess the potential human health and environmental risks associated with using hydraulic containment of {sup 129}I, and to refine transport estimates based on evidence of attenuation. An initial step was to develop and apply a waste-site scale integrated vadose zone-aquifer model. Because viable {sup 129}I remediation technologies for the OU may not be identified in current efforts, a process to facilitate examining the suitability of a technical impracticability waiver for the OU conditions was initiated by defining the monitoring data analysis, documentation, and simulation support that would be needed for obtaining a waiver. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defining Modeling and Analysis Complexity Needs for Remediation - 18425

Many subsurface remedy decisions rely on model predictions or other types of data analyses to support site characterization and remedy selection, design, implementation, performance assessment, and closure. Thus, determining the appropriate level of complexity for modeling and data analysis is important to facilitate subsurface remedy decisions. Multiple factors are important in selecting the appropriate level of complexity in modeling and data analysis. For instance, the type and number of inputs required typically increases with increased complexity of analysis, and the ability to obtain or verify those inputs needs to be considered. The approach needs to establish the relationship between parameters or processes and contaminant transport and the detail of the description needed to meet the analysis objectives. Assessing the modeling complexity associated with the appropriate level of detail can be facilitated by considering complexity of the 1) modeling approach, 2) description of process, and 3) description of heterogeneity. As demonstrated by case studies, using a framework to guide determination of modeling and analysis complexity facilitates selection of the appropriate approach for the site situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Geophysical Information to Investigate Subsurface Structure within the High-Hydraulic Conductivity Analysis Zone

Within the 200 East Area of the Central Plateau and southeastward toward the Columbia River, a high-hydraulic conductivity zone (HCZ) has been interpreted to extend through the 200-PO-1 and 200-BP-5 operable units on the Hanford Site. The HCZ is a controlling hydraulic feature that impacts groundwater flow out of the 200 East Area and the fate of eastwardly migrating plumes from the 200 West Area. The lateral extent of the HCZ is highly uncertain, and despite strong evidence for the existence of the HCZ based on water-level data and contaminant plume tracking, there is still a limited understanding of how to define its boundaries. To provide additional information on the nature and extent of the HCZ, three surface geophysical methods – electrical resistivity tomography (ERT), time-domain electromagnetics (TEM), and seismic methods – were used to collect data south of 200 East. In addition, existing data from 200 East, consisting of surface seismic data, a borehole check shot survey in 699-37-47A, and borehole stratigraphic interpretations, were used to aid interpretations of newly collected seismic data south of 200 East. This work presumed that the contrast in subsurface geophysical properties would be a first-order aid identifying a transmissive zone(s) within the HCZ analysis area by imaging contrasts and/or anomalies in geophysical properties. While seismic, ERT, and TEM methods have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different, and therefore the information can also be different. Figure S.1 shows the locations of the geophysical data considered in this report.

58 GEOSCIENCES↗