Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NRC Reviewer Aid for Evaluating the Human Factors Engineering Aspects of Small Modular Reactors

Small modular reactors (SMRs) are a promising approach to meeting future energy needs. Although the electrical output of an individual SMR is relatively small compared to that of typical commercial nuclear plants, they can be grouped to produce as much energy as a utility demands. Furthermore, SMRs can be used for other purposes, such as producing hydrogen and generating process heat. The design characteristics of many SMRs differ from those of current conventional plants and may require a distinct concept of operations (ConOps). The U.S. Nuclear Regulatory Commission (NRC) conducted research to examine the human factors engineering (HFE) and the operational aspects of SMRs. The research identified thirty potential human-performance issues that should be considered in the NRC's reviews of SMR designs and in future research activities. The purpose of this report is to support NRC HFE reviewers of SMR applications by identifying some of the questions that can be asked of applicants whose designs have characteristics identified in the issues. The questions for each issue were identified and organized based on the review elements and guidance contained in Chapter 18 of the Standard Review Plan (NUREG-0800), and the Human Factors Engineering Program Review Model (NUREG-0711).

08 HYDROGEN↗

Use of immersive 3D virtual reality environments in control room validations - 203

Advanced technologies (e.g., virtual and augmented reality) may provide new possibilities to facilitate control room (CR) design and evaluation activities. We studied how immersive 3D environments may augment and advance the evaluation of safety-critical CR systems. The 3D virtual reality (VR) CR was compared with a real-life development simulator environment where hardwired panels were substituted with Virtual panels. A multi-user functionality enables several operators to be and collaborate in the same VR CR environment at the same time. There is also a realistic representation of emergency operating procedures in the VR CR. Spatial audio communication through headsets makes the experience even more realistic. The results section of the paper address both technical and human factors issues associated with the use of immersive 3D VR environments in CR validation tests, e.g.: amount of technical resources required as compared to normal validation in a real-life simulator environment, creation of methodologically new testing opportunities and new opportunities to data registration and analysis. (authors)

47 OTHER INSTRUMENTATION↗

Executive Summary: Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Under the United States Department of Energy Light Water Sustainability Program (LWRS), Idaho National Laboratory (INL) is collaborating with Palo Verde Generating Station (PVGS) to support human factors engineering efforts in the modernization of PVNGS’ radiological waste system (LRS) control room. The studies proposed and/or conducted by INL are designed to address the inconsistency between different human factors standards, guidance, and conventions. Guidance such as NUREG-0700 leave much of the information open to interpretation. INL will identify whether maintaining a design that is consistent with population stereotypes actually enhances performance, or whether there are alternative designs that yield performance that is better than the designs that maintain those stereotypes. The overall design concept for the LRS workstation includes system overview displays for the Evaporator system and the Boric Acid Concentrator system. A third display contains overview information for the rest of the LRS. The forth display contains alarm information. Each display will be presented on one of four monitors in the control room. The system overview displays contain embedded controls for valves and pumps, mini-trends, and micro-trends. The mini-trends present data for the controllers and contain alarm set point information as well as trending. All other relevant system parameters are shown on micro-trends. The semi-dull screen approach utilized present dynamic data in green, active components are white (gray when closed or off). The product stream flow paths are indicated by different colors. Alarm states are presented in saturated red and selected components are indicated by bright blue. In addition to the micro task study described below, the INL researchers also conducted an evaluation of the semi-dull screen approach as well as an ergonomic evaluation of the suggested upgrades in the local control room. A detailed report of all INL’s activities related to the modernization of the LRS conducted between October 2016 and September 2017 are found in these two reports; • INL-EXT-17-43226, Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room, and • INL-EXT-17-43250, Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Implementation and Analysis for APR1400 Soft Control System

Due to the rapid advancement of digital technology, the definite technical advantages of digital control system compared to analog control system are accelerating the implementation of advanced distributed digital control system in the nuclear power plant. One of the major advantages of digital control system is the capability of Soft Control System. The design of Soft Control System for Advanced Power Reactor 1400 (APR1400) plant of Man-Machine Interface System (MMIS) is based on full digital technologies to enhance reliability, operability and maintainability. Computer-based compact workstation has been adopted in the APR1400 Main Control Room (MCR) to provide convenient working environment. This paper introduces the approaches and methodologies of Soft Control System for the Advanced Control Room (ACR). This paper also explains major design features for operation and display of the Soft Control System and its implementation to cope with regulatory requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bridging the gap: adapting advanced display technologies for use in hybrid control rooms

The Institute for Energy Technology (IFE), runs the OECD Halden Reactor Project (HRP), featuring a state-of-the-art research simulator facility in Halden, Norway, called HAMMLAB. HAMMLAB serves two main purposes: the study of human behaviour in interaction with complex process systems; and the development, test and evaluation of prototype control centres and their individual systems. By studying operator performance in HAMMLAB and integrating the knowledge gained into new designs, the HRP contributes to improving operational safety, reliability, efficiency and productivity. The U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program has contracted IFE to assist DOE national laboratory staff at Idaho National Laboratory (INL) in adapting HAMMLAB design concepts for the purpose of control room modernization at nuclear power plants in the U.S. In support of this effort, the DOE has built a simulator research facility at INL called the Human Systems Simulation Laboratory (HSSL). The HSSL is centered on control room modernization, in which industry provided plant instrumentation and controls are modified for upgrade opportunities. The HSSL houses the LWRS simulator, which is a reconfigurable full-scale and full-scope control room simulator. Consisting of 45 large touchscreens on 15 panels, the LWRS simulator is currently using this glass top technology to digitally represent and replicate the functionality of the analog I&C systems in existing control rooms. The LWRS simulator is reconfigurable in that different plant training simulator models obtained from the utilities can be run on the panels, and the panels can be physically moved and arranged to mimic the layout of those control rooms. The glass top technology and reconfigurability capabilities allow the LWRS simulator to be the research platform that is necessary to design, prototype, and validate human-system interface (HSI) technologies that can replace existing analog I&C. IFE has recently assisted INL in establishing the technical infrastructure for implementation of HSI prototypes from HAMMLAB into the HSSL to demonstrate relevant control room replacement systems in support of the LWRS program. In March, 2014, IFE delivered the first HSI prototype utilizing this infrastructure — a large screen overview display for INL's simulator. The co-operation now continues by developing Procedure Support Displays targeted for operators in hybrid control room settings. These prototypes are being validated with U.S. reactor operators in the HSSL and optimized to enhance their performance. This research serves as a crucial stepping stone toward incorporation of advanced display technologies into conventional main control rooms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of HFE to the design and V and V of a computerized procedure system: benefits and challenges - 234

The application of Human Factors Engineering (HFE) practices to the Human Machine Interface design and subsequent Verification and Validation (V and V) is a widely applied practice when talking about the design of complete control rooms or important control room modernizations, but not so often applied to the design of computerized operator support systems. In order to overcome the challenges faced on designing a Computerized Operation Support System (COSS) that meets the process efficiency requirements and integrates seemingly with hybrid plant operation concept, the involvement of a HFE team early in the COSS design and implementation process along with operation, Instrumentation and Control (I and C) and cybersecurity experts will guarantee the project success. This paper documents the HFE process applied during the design and evaluation of a Computerized Procedure System (CPS) and how final product was shaped to ensure that the transition from paper to computerized procedures will help in meeting Delivering the Nuclear Promise (DNP) goals, improving plant efficiency. The HFE program included the following activities: 1. A review of existing operating experience 2. An analysis of functions and tasks associated to the use and maintenance of CPS 3. A design verification of the system to meet guidelines prescribed in the NUREG-0700 (Rev.2), requirements of the ISG-05 and cybersecurity criteria (NEI 08-09, IEC-62646, EPRI 1015313, these among others). 4. An integrated system validation in a full scope simulator The application of HFE practices in the design and implementation of COSS helps not only to ensure that efficiency and safety improvement requirements are met, but also to evaluate the potential return of the investment, that such tools should bring. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Human factors researchers at Idaho National Laboratory are collaborating with a utility partner to address human factors in the modernization of their radiological waste control room. The collaborating utility, Palo Verde, plans to remove all control boards associated with the liquid radiological waste system, which include controls, indicators, and alarm systems, and replace them with modernized digital instrumentation and controls and displays. To be sure the new system either supports current operational performance or enhances it, researchers have carried out three planning and analysis activities: expert operator review, function allocation analysis, and human factor principles and design applications. Researchers utilized access to expert operators to gain information about the system. Operators were asked to detail a procedure exemplifying typical interactions with the liquid radiological waste system and provide it to Idaho National Laboratory with a list of functionalities to incorporate (Section 4.1). Later, operators were asked to provide additional feedback to inform a prototype with adequate realism to support sound analysis of the system design (Section 4.2). Other operators not associated with the utility partner were also involved in experiment design and prototype evaluation (Section 4.2). Due to the extent of the upgrade, care was given to measure the change in the operator’s role (Section 7). As part of the modernization, some plant systems are expected to be equipped with automation or sensors that send information directly to the control where previously operators were required to enter controlled areas to find the information. Such updates made slight changes to operator role requirements, but the impact was negligible. The way the system is operated will remain largely the same, but operator convenience and safety is expected to increase. Additionally, to map operator tasks during the selected procedure, an Operational Sequence Diagram was created (Section 7.1). The diagram helped to account for every interaction and piece of equipment needed to create the prototype design. Alternatively, the diagram can be created following the final design to identify any function reallocations due to redesign. Human factors principles were also applied to the design. An ergonomic assessment was performed on the workspace resulting in various recommendations for placing and designing the new workstation (Section 6). A 3 D mockup of the control room was created to depict the options available with in-depth descriptions of each. Furthermore the prototype design incorporates well known human factors principles. However, to be sure the principles are sound in the control room context, the researches have designed an experiment to measure the impact design decision has on operator performance. The experiment is described in detail in Section 5. Lastly, a tool emerged as this effort began called the NUREG 0711 Crosswalk (Section 8). The tool has multiple uses, but it was primarily intended to communicate how the researcher’s action directly mapped to specific results suggested in the Nuclear Regulatory Commission review guideline. The tool also maps how current results impact future decisions in the modernization process.

47 OTHER INSTRUMENTATION↗

Integrated emergency control board including design extended conditions for Krsko NPP - 297

In the aim of implementing post-Fukushima safety measures, Krsko Nuclear Power Plant is developing a Safety Upgrade Program. Krsko NPP is upgrading the remote shutdown capabilities and implementing ways to prevent and mitigate the consequences of potential Severe Accidents. This modification enhances remote shutdown capabilities of the plant to prevent potential severe accidents and improve the ways to mitigate their consequences. Within the set of plant design modifications, addressed the design, construction, and commissioning, of a new Emergency Control Room (EMCB. Tecnatom is the responsible of the design modification of the plant together with Idom, that participates with Tecnatom in the project as a joint venture, who provides a new set of field instrumentation, including its design and the corresponding wiring. EMCB integrates Human- System Interface throughout centralizing capabilities to safety shutdown and cooldown the plant as well as to control the new Design Extension Systems. The process relies on a Human Factors Engineering (HFE) analysis applying a specific methodology based on NUREG-0711 . Tecnatom has developed a specific HFE Program Management Plan to proceed with the analysis in a documented, traceable and reliable way. HFE activities ends with an Integrated System Validation in the actual full scope simulator involving MCR crews. This paper describes different phases of the project, the integrated schedule between HFE and I and C activities, benefits of upgrading main and emergency control rooms beyond design bases and addresses Tecnatom lessons learned obtained during the project execution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Migration to a fully-integrated control room - 349

The nuclear industry is faced with a pressing need to reduce operating costs in order to remain competitive with other forms of electric generation. While current industry initiatives are focused on incremental gains by streamlining work processes and reducing worker burdens, very few, if any, involve significant reductions in the base workload of a nuclear plant. Migration to a fully-integrated control room affords just such an opportunity. This report describes an NPP digital instrumentation and control (I and C) system design, along with its corresponding human systems interface (HSI) design, which achieves high plant availability, while selectively applying digital equipment redundancy and integrating traditional I and C system partitions, to minimize the digital equipment needed, and thereby minimize initial installation costs and ongoing operations and maintenance (O and M) costs. An additional key component of digital equipment minimization is optimization of the digital interface to conventional plant sensors and controlled plant devices (e.g., pumps, valves), which requires no disturbance to plant cables and results in eliminating thousands of electro-mechanical relay control components. The design is rooted in the highly integrated digital technology applied to the most recent advanced light water reactors under United States (U.S.) Nuclear Regulatory Commission (NRC) design certification review and approval. While this design employs technology from new plants, that technology has been adapted to the modernization of current operating NPPs. Hence, the highly integrated digital I and C and HSI design is referred to as the compact control room digital modernization (CDM). Along with minimal digital equipment, the corresponding HSI design employs compact operator workstations with visual display units (VDU) and soft controls for both the main control room (MCR) and remote shutdown room (RSR), to immediately improve human performance and ultimately facilitate operating staff reduction. Some advanced light water reactors have demonstrated this staff reduction through full scope simulator testing of normal and abnormal plant conditions, with U.S. licensed operating crews from currently-operating U.S. plants. Digital equipment minimization, compact operator workstations, and optimized plant component interfaces that require no disturbance to field cables, also facilitate implementation of the CDM over multiple phases, most of which can be conducted during normal refueling shutdown windows. This phased implementation method includes a novel transition of the I and C, MCR and RSR with an operations centered focus. This paper presents the CDM design, along with qualitative cost/benefit comparisons to currently operating plants with conventional analog I and C and HSI technology; this generation of I and C/HSI is referred to as a conventional control room (CCR). A CCR also includes NPPs that have been upgraded with digital systems, but retain the current partitions between plant I and C systems (i.e., no I and C integration) and retain the current plant system to control board configuration of current NPP control rooms. Even though these comparisons are qualitative, a compelling case is presented for the CDM. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Human Factors Principles in Information Dashboard Design

When planning for control room upgrades, nuclear power plants have to deal with a multitude of engineering and operational impacts. This will inevitably include several human factors considerations, including physical ergonomics of workstations, viewing angles, lighting, seating, new communication requirements, and new concepts of operation. In helping nuclear power utilities to deal with these challenges, the Idaho National Laboratory (INL) has developed effective methods to manage the various phases of the upgrade life cycle. These methods focus on integrating human factors engineering processes with the plant’s systems engineering process, a large part of which is the development of end-state concepts for control room modernization. Such an end-state concept is a description of a set of required conditions that define the achievement of the plant’s objectives for the upgrade. Typically, the end-state concept describes the transition of a conventional control room, over time, to a facility that employs advanced digital automation technologies in a way that significantly improves system reliability, reduces human and control room-related hazards, reduces system and component obsolescence, and significantly improves operator performance. To make the various upgrade phases as concrete and as visible as possible, an end-state concept would include a set of visual representations of the control room before and after various upgrade phases to provide the context and a framework within which to consider the various options in the upgrade. This includes the various control systems, human-system interfaces to be replaced, and possible changes to operator workstations. This paper describes how this framework helps to ensure an integrated and cohesive outcome that is consistent with human factors engineering principles and also provide substantial improvement in operator performance. The paper further describes the application of this integrated approach in the strategic modernization program at a nuclear power plant where legacy systems are upgraded to advanced digital technologies through a systematic process that links human factors principles to the systems engineering process. This approach will help to create an integrated control room architecture beyond what is possible for individual subsystem upgrades alone. In addition, several human factors design and evaluation methods were used to develop the end-state concept, including interactive sessions with operators in INL’s Human System Simulation Laboratory, three-dimensional modeling to visualize control board changes.

3D Modeling↗

Advanced Control and Protection system Design Methods for Modular HTGRs

The project supported the Nuclear Regulatory Commission (NRC) in identifying and evaluating the regulatory implications concerning the control and protection systems proposed for use in the Department of Energy's (DOE) Next-Generation Nuclear Plant (NGNP). The NGNP, using modular high-temperature gas-cooled reactor (HTGR) technology, is to provide commercial industries with electricity and high-temperature process heat for industrial processes such as hydrogen production. Process heat temperatures range from 700 to 950 C, and for the upper range of these operation temperatures, the modular HTGR is sometimes referred to as the Very High Temperature Reactor or VHTR. Initial NGNP designs are for operation in the lower temperature range. The defining safety characteristic of the modular HTGR is that its primary defense against serious accidents is to be achieved through its inherent properties of the fuel and core. Because of its strong negative temperature coefficient of reactivity and the capability of the fuel to withstand high temperatures, fast-acting active safety systems or prompt operator actions should not be required to prevent significant fuel failure and fission product release. The plant is designed such that its inherent features should provide adequate protection despite operational errors or equipment failure. Figure 1 shows an example modular HTGR layout (prismatic core version), where its inlet coolant enters the reactor vessel at the bottom, traversing up the sides to the top plenum, down-flow through an annular core, and exiting from the lower plenum (hot duct). This research provided NRC staff with (a) insights and knowledge about the control and protection systems for the NGNP and VHTR, (b) information on the technologies/approaches under consideration for use in the reactor and process heat applications, (c) guidelines for the design of highly integrated control rooms, (d) consideration for modeling of control and protection system designs for VHTR, and (e) input for developing the bases for possible new regulatory guidance to assist in the review of an NGNP license application. This NRC project also evaluated reactor and process heat application plant simulation models employed in the protection and control system designs for various plant operational modes and accidents, including providing information about the models themselves, and the appropriateness of the application of the models for control and protection system studies. A companion project for the NRC focused on the potential for new instrumentation that would be unique to modular HTGRs, as compared to light-water reactors (LWRs), due to both the higher temperature ranges and the inherent safety features.

08 HYDROGEN↗

EARLY-STAGE DESIGN AND EVALUATION FOR NUCLEAR POWER PLANT CONTROL ROOM UPGRADES

As control rooms are modernized with new digital systems at nuclear power plants, it is necessary to evaluate operator performance with these systems as part of a verification and validation process. While there is regulatory and industry guidance for some modernization activities, there are no well defined standard processes or predefined metrics available for assessing what is satisfactory operator interaction with new systems, especially during the early design stages. This paper proposes a framework defining the design process and metrics for evaluating human system interfaces as part of control room modernization. The process and metrics are generalizable to other applications and serve as a guiding template for utilities undertaking their own control room modernization activities.

99 GENERAL AND MISCELLANEOUS↗

Nuclear Safety [Vol. 33, No. 4, October-December 1992]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 499 Technical Note: Nuclear Regulatory Commission’s Examination Question Bank System, C. L Jensen and N. L. Skinner; 506 Report on the Specialists’ Meeting on Passive and Active Safety Features of Liquid-Metal Fast Breeder Reactors Organized by the International Atomic Energy Agency at Oarai Engineering Centre of Power Reactor and Nuclear Development Corporation, Japan, November 5-7,1991, S. R. Paranjpe; ACCIDENT ANALYSIS: 514 A Review of Hydrogen Production During Melt/Water Interaction in LWRs, D. F. Fletcher, B. D. Turland, and S. P. A. Lawrence; 535 A Review of the U 3 0 8 -Al Reaction as a Potential Heat Source in Research and Test Reactor Accidents, J. L. Snelgrove; CONTROL AND INSTRUMENTATION: 543 Multilevel Interfaces for Power Plant Control Rooms II: A Preliminary Design Space, K. J. Vicente; DESIGN FEATURES: 549 Twenty-Second DOE/NRC Nuclear Air Cleaning and Treatment Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 562 Book Review: Safety Assessment of Unit 5 (WWER-440/W-213) of the Greifswald Nuclear Power Station, M. H. Fontana; WASTE AND SPENT FUEL MANAGEMENT: 576 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 586 Analysis of Corrective Actions Applied to Nuclear Power Plant Operations, A. E. Cross; 593 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 596 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; 609 Non-Commercial Power Operating Experience; 614 World Nuclear Performance, Compiled by M. D. Muhlheim; RECENT DEVELOPMENTS: 623 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 635 Reports, Standards, and Safety Guides, D. S. Queener; 639 Proposed Rule Changes as of June 30, 1992; ANNOUNCEMENTS: 513 Fourth International Conference on Nuclear Fuel Reprocessing and Waste Management RECOD '94; 585 International Topical Meeting on Advanced Reactors Safety; 622 International Workshop on Implementation of ALARA at Nuclear Power Plants; 648 Short Course on Nuclear Criticality Safety; 648 8th Topical Meeting on Problems in Reactor Physics MEPhi-VOLGA-93; 643 The Authors; 646 Reviewers of Nuclear Safety, Vol. 33

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Meta-Level Design Guidance and Operator Performance Measures for Hybrid Control Rooms

The purpose of this grant was to refine and test methods to evaluate digital human system interfaces (HSI) for existing largely analog nuclear power plant (NPP) control rooms (CRs). We hypothesized that CR operator performance (CROP) in hybrid NPP CRs will be improved if future digital HSI is designed based on: 1) more robust design guidelines for operator situation awareness (SA) and decision-making (DM); 2) enhanced CROP metrics during HSI evaluation; 3) an ontology for selecting simulation scenarios to evaluate digital HSI; and 4) a model to predict optimal HSI design attributes given CROP objectives. The team conducted numerous nuclear power plant site visits (e.g., to Brown’s Ferry, Palo Verde, Sequoyah and Vogtle) to study control room operations and crisis management and 3 visits to the NRC Chattanooga Training Center. We observed research studies at DC Cook and NRC Chattanooga in collaboration with the Halden Reactor Project. We collected operator performance and workload data in one NPP simulator. A comprehensive human (i.e., CROP) performance literature review was published in Applied Ergonomics. We obtained operator team performance data from CAER to produce our data fusion model and a paper delineating the results have been accepted (revision submitted) in Resilience Engineering and System Safety. We analyzed interview data related to scenario ontology development; a manuscript is still in preparation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The effect of support functions in a computerized procedure system on interface management tasks - 235

By adapting digital and computer technology, the design of main control rooms (MCR) in nuclear power plants has been changed. When operators operate a nuclear power plant, the tasks using soft controls in advanced MCRs include primary tasks and secondary tasks. Primary tasks are to control nuclear power plant devices and secondary tasks are to find appropriate screens or devices by screen navigations and selections before performing the primary task. The secondary task including interface management tasks is newly introduced in advanced MCRs. In this paper, the tasks are analyzed based on the simulation data of APR1400 which is one of the digitalized nuclear power plants. For analyzing tasks, the unit tasks are divided into three types: navigation, manipulation, and acknowledgement. The primary task represents the manipulation of devices and the secondary task indicates the navigating screens, opening control panels, closing control panels, and confirming the acknowledging alarms. To analyze the effect of support functions of a computerized procedure system (CPS), one of the functions which is expected to have a significant effect on the secondary tasks was considered, that is 'related screen link button.' Two factors, 'ratio of screen alteration' and 'ratio of using screen link button', were used to see the effect of 'related screen link button'. From the task analysis result, it was observed that the secondary tasks which is one of the unique features in advanced MCRs have a quite much portion than that of the primary tasks. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A human automation interaction concept for a small modular reactor control room - 101

Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗