Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Strategy, Setpoint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Distribution System Restoration Strategy for Resilience Enhancement: Preprint

In electric power distribution systems, distributed energy re-sources (DERs) can act as controllable power sources and support utility operators to minimize power outages after ex-treme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influ-ences of extreme events and the capabilities of DERs are dy-namic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availabil-ity of DERs. In this paper, we propose a new dynamic distribu-tion system restoration strategy to enhance system resilience against potential hazards. An efficient reconfiguration algo-rithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER opera-tion setpoints based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Multiagent Resource Sharing Algorithm for Control of Advanced Energy Systems

This paper implements a novel resource sharing control strategy on a fuel cell–gas turbine hybrid power system at the National Energy Technology Laboratory’s Hybrid Performance Facility (Hyper). In a fuel cell–gas turbine hybrid power system, the simultaneous interaction of the gas turbine and the fuel cell creates a tightly coupled environment characterized by conflicting dynamics. In this paper, a model-free control approach is applied to solve the tightly coupled control problem posed by this challenging environment. Specifically, this control problem is presented as a resource sharing problem that can be solved using a resource sharing algorithm that is defined based on the distribution construction concept. This algorithm creates computational agents and solves the problem through the distribution and redistribution of shared resources defined as blocks. Furthermore, two agents were created; the first agent (agent 1) controls the gas turbine speed by adjusting the electric load, and the second agent (agent 2) controls the cathode mass flow through the fuel cell using the cold-air bypass valve. A parametric study was performed over the course of 15 experimental tests for both agents 1 and 2 through an evaluation of the responses based on setpoint changes. The algorithm was shown to have behavior comparable to a previously implemented multi-input multioutput state-space controller, which was designed through a model-based control approach. The resource sharing algorithm was able to find stable performance during run-time operations without any prior system knowledge identification on the power plant and without creating models used in traditional control strategies.

25 ENERGY STORAGE↗

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis↗

Point to Point Control of the Hydrogen Mixer

We continue to build on the theoretical modelling of a liquid hydrogen (LH2) and gas hydrogen (GH2) mixer subsystem. The mixer described in this work is responsible for combining high pressure LH2 and GH2 to produce a hydrogen flow that meets certain thermodynamic properties. The desired properties are maintained by precise control of the LH2 and GH2 flows. The mixer is modelled as a general multi-flow lumped volume for single constituent fluids using density and internal energy as states. The set of nonlinear differential equations is modelled in the SIMULINK environment including a table look-up feature of the fluid thermodynamic properties. A small signal (linear) model is developed based on the nonlinear model and simulated as well. Pulse disturbances are introduced to the valve positions and the quality of the linear model is ascertained by comparing its behavior against the nonlinear model simulations. Valve control strategies that simulate an operator-in-the-loop scenario are then explored demonstrating the need for automatic feedback control. Finally, optimal single-output and multi-output Proportional/Integral controllers are designed based on the linear model and applied to the nonlinear model with excellent results to track simultaneous, constant setpoint changes in desired exit flow, exit temperature, and mixer pressure, as well as to reject unmeasureable but bounded additive step perturbations in the valve positions.

Barbieri, Enrique↗

Modeling, Simulation and Control of a Propellant Mixer

This paper addresses some modeling and control issues for a mixing chamber used in rocket engine testing at NASA Stennis Space Center. The mixer must combine high pressure liquid hydrogen (LH2) and gaseous hydrogen (GH2) to produce and output flow that meets certain thermodynamic properties before it is fed into a test article. More precisely, this paper considers that the quantities to be tracked and/or regulated are mixer internal pressure, exit mass flow, and exit temperature. The available control inputs are given by three value positions, namely those of the GH2, LH2 and exit valves. The mixer is modelled by a system of two nonlinear ordinary differential equations having density and internal energy as states. The model must be simple enough to lend itself to subsequent feedback controller design, yet its accuracy must be tested against real data. For this reason, the model includes function calls to thermodynamic property data. Some structural properties of the resulting model that pertain to controller design, such as controllability and uniqueness of the equilibrium point are shown to hold. Validation of the model against real data is also provided. As a first control approach, a small-signal (linear) model is developed based on the nonlinear model and simulated as well. Pulse disturbances are introduced to the valve positions and the quality of the linear model is ascertained by comparing its behavior against the nonlinear model simulations. Valve control strategies that simulate an operator-in-the-loop scenario are then explored demonstrating the need for automatic feedback control. Classical optimal single-output and multi-output Proportional/Integral controllers are designed based on the linear model and applied to the nonlinear model with excellent results to track simultaneous, constant setpoint changes in desired exit flow, exit temperature, and mixer pressure, as well as to reject unmeasurable but bounded additive step perturbations in the valve positions. A feedback linearization controller is designed and used to achieve tracking and regulation of the outputs over an extended range of the variables of interest.

Richter, Hanz↗

Small Signal Point-to-Point Tracking of a Propellant Mixer

This paper addresses some theoretical modelling and control issues for a mixing chamber used in rocket engine testing at NASA Stennis Space Center. The mixer is responsible for combining high pressure LH2 and GH2 to produce a hydrogen flow that meets certain thermodynamic properties before it is fed into a test article. The desired properties are maintained by precise control of the LH2 and GH2 flows. The mixer is modelled as a general multi-flow lumped volume for single constituent fluids using density and internal energy as states. The set of nonlinear differential equations is modelled in the SIMULINK environment including a table look-up feature of the fluid thermodynamic properties. a small-signal (linear) model is developed based on the nonlinear model and simulated as well. Pulse disturbances are introduced to the valve positions and the quality of the linear model is ascertained by comparing its behavior against the nonlinear model simulations. Valve control strategies that simulate an operator-in-the-loop scenario are then explored demonstrating the need for automatic feedback control. Finally, classical optimal single-output and multi-output Proportional/Integral controllers are designed based on the linear model and applied to the nonlinear model with excellent results to track simultaneous, constant setpoint changes in desired exit flow, exit temperature, and mixer pressure, as well as to reject unmeasurable but bounded additive step perturbations in the valve positions.

Barbieri, Enrique↗

Using energy storage systems to extend the life of hydropower plants

Despite their advantages, distributed energy resources (DERs) bring inherent uncertainty and variability into the landscape of modern power systems. As DER penetration grows, conventional generators like hydropower plants have to respond more often to arrest the imbalance in the net load. Hydropower turbines provide their best operational performance with minimal wear and tear when operating at regions of maximum efficiency. However, the current needs for hydropower plants require them to operate under varying load conditions and thus sub-optimal operating points leading to additional stress. To relieve the hydropower plants, this paper proposes a hybridization strategy where a hydropower unit is paired with an energy storage system (ESS) to increase operational flexibility and mitigate damage to the hydro plant. Models are developed to represent the operation of the hybrid system, quantify degradation, and assess economic benefits. Moreover, an innovative controller disaggregates the market dispatch signal into separate control setpoints for the ESS and hydropower unit. In case studies performed on a real-world hydropower facility, it was found that the ESS-based hybridization can extend the life of the hydropower plant by 5% on average. Notably, the economic benefits from reduced maintenance and deferred investment are estimated to be around $3.6 million.

13 HYDRO ENERGY↗

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Adaptive Data-Driven Model Predictive Control for Heat Pipe Microreactors

To establish a technical basis for self-regulating microreactors, a model predictive control (MPC) system is investigated to proactively respond to anomalies and disturbances in anticipation of potential deviations from operating setpoints. Due to the difficulty of developing a physics-based surrogate model that can accurately match plant data in various operating conditions, machine learning algorithms are used in MPC, which allow for learning from both simulation and operation data, thus efficiently describing the targeted transient with arbitrary accuracy. However, one of the biggest concerns in applying ML algorithms like artificial neural networks (ANNs) is that the predictive capabilities of ANN are limited by training data. If there are gaps between the training and target domain, the accuracy of an ANN can degrade significantly when it is used to predict unseen data. To improve the predictive capability of ANN and enable a confident use of data-driven MPCs outside the training data, this study proposes an adaptive data-driven MPC framework. The system will monitor the discrepancy between plant responses and surrogate predictions, fine-tune the ANN-based surrogate when a large discrepancy is detected, and continue MPC operation with updated surrogates. The framework is demonstrated on a point kinetic model for microreactors. The hyperparameters of the update strategy, including layers to update, error thresholds, learning rate discount, and number of data points used for fine-tuning, are optimized so the simulated microreactor is able to follow changes in setpoint with the smallest of deviations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adaptable Data Driven Model Predictive Control for Heat Pipe Microreactors

To establish a technical basis for self-regulating microreactors, a model predictive control (MPC) system is investigated to proactively respond to anomalies and disturbances in anticipation of potential deviations from operating setpoints. Due to the difficulty of developing a physics-based surrogate model that can accurately match plant data in various operating conditions, machine learning algorithms are used in MPC, which allow for learning from both simulation and operation data, thus efficiently describing the targeted transient with arbitrary accuracy. However, one of the biggest concerns in applying ML algorithms like artificial neural networks (ANNs) is that the predictive capabilities of ANN are limited by training data. If there are gaps between the training and target domain, the accuracy of an ANN can degrade significantly when it is used to predict unseen data. To improve the predictive capability of ANN and enable a confident use of data-driven MPCs outside the training data, this study proposes an adaptive data-driven MPC framework. The system will monitor the discrepancy between plant responses and surrogate predictions, fine-tune the ANN-based surrogate when a large discrepancy is detected, and continue MPC operation with updated surrogates. The framework is demonstrated on a point kinetic model for microreactors. The hyperparameters of the update strategy, including layers to update, error thresholds, learning rate discount, and number of data points used for fine-tuning, are optimized so the simulated microreactor is able to follow changes in setpoint with the smallest of deviations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Virtual Battery Aggregator (Virtual Battery Aggregator for Distributed Energy Resource Management Systems)

Distributed energy resource management systems (DERMS) are being deployed in feeders with high distributed energy resource (DER) penetration to provide visibility of DERs and enable DER control strategies for grid operators. DERMS can support centralized grid controls by aggregating individual DER information into a single virtual DER model. This codebase creates algorithms for a DERMS platform that are able to aggregate a set of DERs that can be modeled as batteries, create a virtual battery model for centralized grid controls, and dispatch power setpoints to the individual DERs based on a desired virtual power setpoint received from the centralized grid control. It integrates with existing co-simulation frameworks and models for buildings, DERs, and distribution systems. While the DERMS is designed to work with batteries, it can be used with any DER that can be defined by a generalized battery model.

Blonsky, Michael↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Supervisory Control System for Thermal Energy Distribution System

The integrated energy system (IES) refers to the combination of nuclear energy generation with other energy sources to enable the efficiency and reliability of power generations. To create technologically viable and economically competitive systems, supervisory control strategies are critical for optimizing performance and ensuring stability across different energy generation, transportation, and utilization. This work focuses on the control strategies for the thermal energy distribution system (TEDS), which is a cornerstone of the Dynamic Energy Transport and Integration Laboratory at Idaho National Laboratory. TEDS currently relies on operators to coordinate across different components to manage energy storage and ensure efficiency. This work demonstrates the use of model predictive control (MPC) with surrogate models in determining optimal setpoints for major TEDS components. The capability of MPC-based supervisory control system is evaluated by autonomously matching the power outputs from a Dymola-based TEDS with target heat demands.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗