Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integration of STOL airplanes into the ATC system

The study involving the STOL airplane and air traffic control is a joint NASA/FAA effort designed to examine the effects of introducing large numbers of STOL airplanes into a high-density terminal area. Simply stated, the objectives of the study are to determine the effects of the STOL airplane on the air traffic control (ATC) system and to determine the effects of the ATC system on the STOL airplane. More specifically, the study seeks to determine the airspace requirements and air traffic control equipment and handling techniques required to accommodate the STOL airplane in the ATC system and the design characteristics, avionics equipment, and flight procedures required to operate the STOL airplane in the air traffic control system.

Peterson, P.↗

Fusion-based occupancy sensing for building systems

Sensing and control apparatus for a building HVAC system includes interior and boundary sensors, such as cameras and thermal sensors, generating sensor signals conveying occupancy-related features for an area. A controller uses the sensor signals to produce an occupancy estimate and to generate equipment-control signals to cause the HVAC system to supply conditioned air to the area based on the occupancy estimate. The controller includes fusion systems collectively generating the occupancy estimate by corresponding fusion calculations, the fusion systems producing a boundary occupancy-count change based on sensor signals from the boundary sensors, an interior occupancy count based on sensor signals from the interior sensors, and the overall occupancy estimate. Fusion may be of one or multiple types including cross-modality fusion across different sensor types, within-modality fusion across different instances of same-type sensors, and cross-algorithm fusion using different algorithms for the same sensor(s).

Konrad, Janusz L.↗

Flight test of a displacement sidearm controller

A six-axis displacement-stick sidearm controller was developed to enable single-handed control of remote manipulator operations in space. With a working model available, piloted evaluation became possible in a fly-by-computer variable-stability research aircraft, originally a Bell 205 helicopter. The original mechanization was limited to three rotational axes and a linear one, analogous to the collective stick. A newly designed short stickgrip was mounted and the spring force pattern adjusted to suit the helicopter flight control environment. A standard set of test maneuvers was flown by four experimental pilots with conventional helicopter flight controls and with sidearm controllers equipped with two different handgrips. Existing data from flight tests with an isometric-stick controller were added to complete the comparison. The displacement controller consistently achieved a rating of 3.0 to 3.5 on the Cooper-Harper scale, on par with the conventional controls. The same basic controller design was tested in spacecraft and remote manipulator simulations with very promising results. In each application operator/system integration was rapid and positive. The results demonstrate feasibility and support the design philosphy of using deflection as well as force to generate proprioceptive feedback.

Lippay, A. L.↗

The management of energy utilization in a spacecraft tracking station and its industrial applications

The mission of a tracking station within the NASA/Jet Propulsion Deep Space Network is characterized by a wide diversity of spacecraft types, communications ranges, and data accuracy requirements. In the present paper, the system architecture, communications techniques, and operators interfaces for a utility controller are described. The control equipment as designed and installed is meant to be a tool to study applications of automated control in the dynamic environment of a tracking station. It allows continuous experimenting with new technology without disruption of the tracking activities.

Reynolds, R.↗

Innovation for Pollution Control

Kinetic Controls Inc.'s refuse-fired steam generating facility led to the development of an air pollution equipment control device. The device is currently marketed by two NASA/Langley Research Center employees. It automatically senses and compensates for the changes in smoke composition when refuse is used as a fuel by adjusting the precipitator's voltage and current to permit maximum collection of electrically charged dust particles. The control adapts to any electrostatic precipitator and should have extensive commercial applications.

Source record↗

2021 Component Innovation Awardee: Windurance, LLC

Distributed wind turbine manufacturers seeking to enter the market are often hampered by two challenges: not enough capital and no specific expertise in developing certified electronic equipment. A harsh reality is that off-the-shelf power electronics are neither certified nor cost-effective. This lack of certified controller equipment in the distributed wind energy industry adds expense and impedes market penetration related to certification for individual wind turbines, wind system projects, and installations. Normally, these certification costs would be borne repeatedly by individual turbine manufacturers or developers on a model-by-model or project-by-project basis, resulting in cost and time delays as well as uncertainty and risk for project developers and prospective owners. Windurance seeks to eliminate these challenges by developing and obtaining third-party certification of a standardized wind turbine controller. This will facilitate development, certification, and production while supporting efficiencies not easily achievable by individual manufacturers. Windurance's Distributed Wind Industry Turbine Controller will enable manufacturers to apply proprietary turbine- specific configurations and functionality. When applicable, manufacturers can expand on a Windurance-provided software framework to add unique or proprietary functionality.

CIP↗

Risk Reduction of Orion Multi-Purpose Crew Vehicle (MPCV) Program Government-Furnished Equipment for Environmental Control and Life Support (ECLS)

The NASA Engineering and Safety Center (NESC) was requested to conduct technical risk-reduction activities for safety-critical government-furnished environmental control and life support (ECLS) equipment for the Multi-Purpose Crew Vehicle Program. These items include the post-landing anomaly gas monitor, the in-flight anomaly gas monitor, the emergency breathing mask, the 144-hour in-suit survival capability, the portable fire extinguisher, the smoke eater, and the post-landing carbon dioxide control system. This document contains the outcome of the NESC assessment.

Environmental Control and Life Support↗

Development of electrical feedback controlled heat pipes and the advanced thermal control flight experiment

The development and characteristics of electrical feedback controlled heat pipes (FCHP) are discussed. An analytical model was produced to describe the performance of the FCHP under steady state and transient conditions. An advanced thermal control flight experiment was designed to demonstrate the performance of the thermal control component in a space environment. The thermal control equipment was evaluated on the ATS-F satellite to provide performance data for the components and to act as a thermal control system which can be used to provide temperature stability of spacecraft components in future applications.

Bienert, W. B.↗

Computer assisted thermal-vacuum testing

In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.

Petrie, W.↗

Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for

This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.

Electrical and Electronics↗

NASA Ames Research Center 60 MW Power Supply Modernization

The NASA Ames Research Center 60 MW DC Power Supply was built in 1974 to provide controlled DC power for the Thermophysics Facility Arc Jet Laboratory. The Power Supply has gradually losing reliability due to outdated technology and component life limitation. NASA has decided to upgrade the existing rectifier modules with contemporary high-power electronics and control equipment. NASA plans to complete this project in 2001. This project includes a complete replacement of obsolete thyristor stacks in all six rectifier modules and rectifier bridge control system. High power water-cooled thyristors and freewheeling diodes will be used. The rating of each of the six modules will be 4000 A at 5500 V. The control firing angle signal will be sent from the Facility Control System to six modules via fiberoptic cable. The Power Supply control and monitoring system will include a Master PLC in the Facility building and a Slave PLC in each rectifier module. This system will also monitor each thyristor level in each stack and the auxiliary equipment.

Choy, Yuen Ching↗

Automated space processing payloads study. Volume 2, book 1: Technical report

The extent was investigated to which experiment hardware and operational requirements can be met by automatic control and material handling devices; payload and system concepts that make extensive use of automation technology are defined. Hardware requirements for each experiment were established and tabulated, and investigations of applicable existing hardware were documented. The capabilities and characteristics of industrial automation equipment, controls, and techniques are presented in the form of a summary of applicable equipment characteristics in three basic mutually-supporting formats. Facilities for performing groups of experiments are defined along with four levitation groups and three furnace groups; major hardware elements required to implement them were identified. A conceptual design definition of ten different automated processing facilities is presented along with the specific equipment to implement each facility and the design layouts of the different units. Constraints and packaging, weight, and power requirements for six payloads postulated for shuttle missions in the 1979 to 1982 time period were examined.

Source record↗

Research study on multi-KW-DC distribution system

A detailed definition of the HVDC test facility and the equipment required to implement the test program are provided. The basic elements of the test facility are illustrated, and consist of: the power source, conventional and digital supervision and control equipment, power distribution harness and simulated loads. The regulated dc power supplies provide steady-state power up to 36 KW at 120 VDC. Power for simulated line faults will be obtained from two banks of 90 ampere-hour lead-acid batteries. The relative merits of conventional and multiplexed power control will be demonstrated by the Supervision and Monitor Unit (SMU) and the Automatically Controlled Electrical Systems (ACES) hardware. The distribution harness is supported by a metal duct which is bonded to all component structures and functions as the system ground plane. The load banks contain passive resistance and reactance loads, solid state power controllers and active pulse width modulated loads. The HVDC test facility is designed to simulate a power distribution system for large aerospace vehicles.

Berkery, E. A.↗

A 7.6m /25-ft/ extreme environments simulator

Stainless steel cylindrical simulation chamber permits testing equipment under extreme cold, high partial vacuums, and intense solar radiation. Applications include heat balance and temperature distribution studies, investigations of subsystem interactions, tests of attitude control equipment and sensors, and acceptance tests of complete systems.

Argoud, M. J.↗

PV-Diesel Hybrid SCADA Experiment Network Design

The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.

Kalu, Alex↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗