Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

A Cryogenically-Cooled MW Inverter for Electric Aircraft Propulsion

Power electronic converter will be a key enabler for future electrified aircraft propulsion system. In aircraft applications, superconducting technologies such as superconducting motors and generators along with supporting power systems will grow in importance. Utilizing cryogenic cooling for power converter potentially can significantly improve the inverter system efficiency and specific power. This paper presents the cooling, hardware,and testing of a cryogenically-cooled MW inverter developed for electrified aircraft propulsion system. The 1 MVA full load testing with cryogenic cooling is demonstrated. The developed inverter system achieves 18 kVA/kg specific power and 99% efficiency, which provides a promising solution to achieve high power density and efficiency for future electrified aircraft propulsion system.

cryogenically-cooled inverter↗

Transmissive concentrated photovoltaic module with cooling system

A spectrum splitting, transmissive concentrating photovoltaic (tCPV) module is proposed and designed for a hybrid photovoltaic-solar thermal (PV/T) system. The system may be able to fully utilize the full spectrum of incoming sunlight. By utilizing III-V triple junction solar cells with bandgaps of approximately 2.1 eV, 1.7 eV, and 1.4 eV in the module, ultraviolet (UV) and visible light (in-band light) are absorbed and converted to electricity, while infrared (IR) light (out-of-band light) passes through and is captured by a solar thermal receiver and stored as heat. The stored heat energy may be dispatched as electricity or process heat as needed. The tCPV module may have an overall power conversion efficiency exceeding 43.5% for above bandgap (in-band) light under a standard AM1.5D solar spectrum with an average concentration ratio of 400 suns. Passive and/or active cooling methods may be used to keep cells below 110° C. while transmitting >75% of out-of-band light to the thermal receiver, which may attain thermal energy capture at temperatures as high as 500° C. or more. A transparent active cooling system may improve the CPV module efficiency by about 1% (absolute) relative to a passive cooling system by reducing the maximum cell working temperature by about 16° C.

Escarra, Matthew David↗

Optimizations of a Rectilinear Cooling Channel for a Future Muon Collider

Muon colliders require significant beam cooling to achieve the luminosity needed for high-energy physics experiments. Ionization cooling has emerged as a promising solution. This study optimizes a rectilinear muon cooling channel using a multi-objective optimization framework that integrates beam dynamics simulations. We present novel optimizations of final 6D emittance versus total system length as well as those confirming the theoretical trade-offs between transverse and longitudinal emittance. Our results optimizing all stages of the system simultaneously surpass performance benchmarks reported in the literature, demonstrating possible ways to improve the efficiency of such a cooling system.

Zhang, Aubrey [U. Chicago (main)]↗

Optimizations of a Rectilinear Cooling Channel for a Future Muon Collider

Muon colliders require significant beam cooling to achieve the luminosity needed for high-energy physics experiments. Ionization cooling has emerged as a promising solution. This study optimizes a rectilinear muon cooling channel using a multi-objective optimization framework that integrates beam dynamics simulations. We present novel optimizations of final 6D emittance versus total system length as well as those confirming the theoretical trade-offs between transverse and longitudinal emittance. Our results optimizing all stages of the system simultaneously surpass performance benchmarks reported in the literature, demonstrating possible ways to improve the efficiency of such a cooling system.

Zhang, Aubrey [U. Chicago (main)]↗

Active Control of Jets in Cross-Flow for Film Cooling Applications

Jets in cross-flow have applications in film cooling of gas turbine vanes, blades and combustor liners. Their cooling effectiveness depends on the extent to which the cool jet-fluid adheres to the cooled component surface. Lift-off of the cooling jet flow or other mechanisms promoting mixing, cause loss of cooling effectiveness as they allow the hot "free-stream" fluid to come in contact with the component surface. The premise of this project is that cooling effectiveness can be improved by actively controlling (e.9. forcing, pulsing) the jet flow. Active control can be applied to prevent/delay lift-off and suppress mixing. Furthermore, an actively controlled film-cooling system coupled with appropriate sensory input (e.g. temperature or heat flux) can adapt to spatial and temporal variations of the hot-gas path. Thus, it is conceivable that the efficiency of film-cooling systems can be improved, resulting in coolant fluid economy. It is envisioned that Micro Electro-Mechanical Systems (MEMS) will play a role in the realization of such systems. As a first step, a feasibility study will be conducted to evaluate the concept, identify actuation and sensory elements and develop a control strategy. Part of this study will be the design of a proof-of-concept experiment and collection of necessary data.

Nikitopoulos, Dimitris E.↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient engine high-pressure turbine component rig performance test report

A rig test of the cooled high-pressure turbine component for the Energy Efficient Engine was successfully completed. The principal objective of this test was to substantiate the turbine design point performance as well as determine off-design performance with the interaction of the secondary flow system. The measured efficiency of the cooled turbine component was 88.5 percent, which surpassed the rig design goal of 86.5 percent. The secondary flow system in the turbine performed according to the design intent. Characterization studies showed that secondary flow system performance is insensitive to flow and pressure variations. Overall, this test has demonstrated that a highly-loaded, transonic, single-stage turbine can achieve a high level of operating efficiency.

Leach, K. P.↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

Two-Phase Thermal Switching System for a Small, Extended Duration Lunar Science Platform

Issue: extended duration lunar science platforms, using solar/battery or radioisotope power, require thermal switching systems that: a) Provide efficient cooling during the 15-earth-day 390 K lunar day; b) Consume minimal power during the 15-earth-day 100 K lunar night. Objective: carry out an analytical study of thermal switching systems that can meet the thermal requirements of: a) International Lunar Network (ILN) anchor node mission - primary focus; b) Other missions such as polar crater landers. ILN Anchor Nodes: network of geophysical science platforms to better understand the interior structure/composition of the moon: a) Rationale: no data since Apollo seismic stations ceased operation in 1977; b) Anchor Nodes: small, low-power, long-life (6-yr) landers with seismographic and a few other science instruments (see next chart); c) WEB: warm electronics box houses ILN anchor node electronics/batteries. Technology Need: thermal switching system that will keep the WEB cool during the lunar day and warm during the lunar night.

Bugby, D.↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IGCC performance comparison for variations in gasifier type and gas turbine firing temperature

Performance estimates were made for a series of integrated coal gasification combined cycle (IGCC) power systems using three generic types of coal gasification subsystems. The objectives of this study were (1) to provide a self consistent comparison of IGCC systems using different types of gasifiers and different oxidants and (2) to use this framework of cases to evaluate the effect of a gas turbine firing temperature and cooling approach an overall system efficiency. The basic IGCC systems considered included both air and oxygen blown versions of a fluidized bed gasifier, represented by the Westinghouse design, and an entrained bed gasifier, represented by the Texaco design. Also considered were systems using an oxygen blown, fixed bed gasifier, represented by the British Gas Corporation (BGC) slagging gasifier. All of these gasifiers were integrated with a combined cycle using a gas turbine firing temperature of 1700 K (2600 F) and a compressor pressure ratio of 16:1. Steam turbine throttle conditions were chosen to be 16.6 MPa/811 K (2400 psia/1000 F) with a single reheat to 810 K (1000 F). Some of these cases were modified to allow the evaluation of the effect of gas turbine firing temperature. Turbine firing temperatures from state of the art 1365 K (2000 F) to an advanced technology 1920 K (3000 F) were analyzed. A turbine cooling technology that maintains metal temperatures below acceptable limits was assumed for each level of firing temperature. System performance comparisons were made using three advanced turbine cooling technologies for the 1920 K (3000 F) firing temperature. The results indicate that the IGCC using the BGC gasifier had the highest net system efficiency (42.1 percent) of the five gasification cases considered.

Stochl, R. J.↗