Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cost Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Decarbonizing the US Energy System

Recent rapid and unexpected cost reductions in decarbonization technologies have accelerated the cost-effective decarbonization of the US economy, with greenhouse gas (GHG) emissions falling by 20% from 2005 to 2020. The literature on US economy-wide decarbonization focuses on maximizing long-term GHG emissions reduction strategies that rely mostly on renewable energy expansion, electrification, and efficiency improvements to achieve net-zero GHG emissions by 2050. While these studies provide a valuable foundation, further research is needed to properly support decarbonization policy development and implementation. In this review, we identify key decarbonization analysis gaps and opportunities, including issues related to cross-sectoral linkages, spatial and temporal granularity, consumer behavior, emerging technologies, equity and environmental justice, and political economy. We conclude by discussing the implications of these analysis gaps for US decarbonization pathways and how they relate to challenges facing major global emitters.

08 HYDROGEN↗

Optimized Floating Offshore Wind Turbine Substructure Design Trends for 10–30 MW Turbines in Low-, Medium-, and High-Severity Wave Environments

Floating offshore wind is a promising renewable energy source, as 60% of the wind resources globally are found at depths requiring floating technologies, it minimizes construction at sea, and provides opportunities for industrialization given a lower site dependency. While floating offshore wind has numerous advantages, a current obstacle is its cost in comparison to more established energy sources. One cost-reduction approach for floating wind is increasing turbine capacities, which minimizes the amount of foundations, moorings, cables, and O&M equipment. This work presents trends in mass-optimized VolturnUS hull designs as turbine capacity increases for various wave environments. To do this, a novel rapid hull optimization framework is presented that employs frequency domain modeling, estimations of statistical extreme responses, industry constructability requirements, and genetic algorithm optimization to generate preliminary mass-optimal VolturnUS hull designs for a given turbine design and set of site conditions. Using this framework, mass-optimized VolturnUS hull designs were generated for 10–30 MW turbines for wave environments of varying severities. These design studies show that scaling up turbine capacities increases the mass efficiency of substructure designs, with decreasing returns, throughout the examined turbine capacity range. Additionally, increased wave environment severity is shown to increase the required mass of a given substructure design.

VolturnUS↗

Accelerating multilevel Markov Chain Monte Carlo using machine learning models

Here, this work presents an efficient approach for accelerating multilevel Markov Chain Monte Carlo (MCMC) sampling for large-scale problems using low-fidelity machine learning models. While conventional techniques for large-scale Bayesian inference often substitute computationally expensive high-fidelity models with machine learning models, thereby introducing approximation errors, our approach offers a computationally efficient alternative by augmenting high-fidelity models with low-fidelity ones within a hierarchical framework. The multilevel approach utilizes the low-fidelity machine learning model (MLM) for inexpensive evaluation of proposed samples thereby improving the acceptance of samples by the high-fidelity model. The hierarchy in our multilevel algorithm is derived from geometric multigrid hierarchy. We utilize an MLM to accelerate the coarse level sampling. Training machine learning model for the coarsest level significantly reduces the computational cost associated with generating training data and training the model. We present an MCMC algorithm to accelerate the coarsest level sampling using MLM and account for the approximation error introduced. We provide theoretical proofs of detailed balance and demonstrate that our multilevel approach constitutes a consistent MCMC algorithm. Additionally, we derive the expression for cost reduction due to machine learning model to facilitate cost analysis of the hierarchical sampling algorithm. Our technique is demonstrated on a standard benchmark inference problem in groundwater flow, where we estimate the probability density of a quantity of interest using a four-level MCMC algorithm. Our proposed algorithm accelerates multilevel sampling by a factor of two while achieving similar accuracy compared to sampling using the standard multilevel algorithm.

97 MATHEMATICS AND COMPUTING↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Misalignment Tolerant Three-phase Wireless Fast Charging System for Electric Vehicles

This project proposes improving the technology level of the three-phase wireless charging technology developed at Oak Ridge National Laboratory (ORNL). Successful commercialization of wireless charging systems require that they meet strict safety standards for electromagnetic field emissions and interoperability with other wireless charging technology. ORNL has previously demonstrated a 50kW three-phase wireless power transfer system with 95% efficiency. This prototype system weighed less than 50% of similar high-power wireless charging system while simultaneously exhibiting better safety characteristics. Due to better material utilization, the reduction in mass is expected to translate into similar cost reduction for the magnetic coupler. Additionally, the smaller footprint of the system can ease vehicle integration difficulties that would be encountered using other technology. Furthermore, the three-phase design can be made to operate with existing single-phase coupler design more easily and without intentional physical misalignment which would otherwise pose safety issues.This project developed ORNL’s WPT technology to satisfy the specifications and requirements for electric vehicle (EV) charging. The result of the project will be a prototype and reference design for a high-power wireless charging system—including magnetics, power electronics, and controls—serving as a baseline for product development.

33 ADVANCED PROPULSION SYSTEMS↗

Misalignment Tolerant Three-phase Wireless Fast Charging System for Electric Vehicles

This project proposes improving the technology level of the three-phase wireless charging technology developed at Oak Ridge National Laboratory (ORNL). Successful commercialization of wireless charging systems require that they meet strict safety standards for electromagnetic field emissions and interoperability with other wireless charging technology. ORNL has previously demonstrated a 50kW three-phase wireless power transfer system with 95% efficiency. This prototype system weighed less than 50% of similar high-power wireless charging system while simultaneously exhibiting better safety characteristics. Due to better material utilization, the reduction in mass is expected to translate into similar cost reduction for the magnetic coupler. Additionally, the smaller footprint of the system can ease vehicle integration difficulties that would be encountered using other technology. Furthermore, the three-phase design can be made to operate with existing single-phase coupler design more easily and without intentional physical misalignment which would otherwise pose safety issues. This project developed ORNL’s WPT technology to satisfy the specifications and requirements for electric vehicle (EV) charging. The result of the project will be a prototype and reference design for a high-power wireless charging system—including magnetics, power electronics, and controls—serving as a baseline for product development.

33 ADVANCED PROPULSION SYSTEMS↗

Charting the Path to Electrification: Analyzing the Economic and Technological Potential of Advanced Vehicle Powertrains

The U.S. Department of Energy’s Vehicle Technologies Office (DOE-VTO) is driving advancements in highway transportation by targeting energy efficiency, environmental sustainability, and cost reductions. This study investigates the fuel economy potential and cost implications of advanced powertrain technologies using comprehensive system simulations. Leveraging tools such as Autonomie and TechScape, developed by Argonne National Laboratory, this study evaluates multiple timeframes (2023–2050) and powertrain types, including conventional internal combustion engines, hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), and battery electric vehicles (BEVs). Simulations conducted across standard regulatory driving cycles provide detailed insights into fuel economy improvements, cost trajectories, and total cost of ownership. The findings highlight key innovations in battery energy density, lightweighting, and powertrain optimization, demonstrating the growing viability of BEVs and their projected economic competitiveness with conventional vehicles by 2050. This work delivers actionable insights for policymakers and industry stakeholders, underscoring the transformative potential of vehicle electrification in achieving sustainable transportation goals.

Islam, Ehsan Sabri (ORCID:0000000200220180)↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai'i

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy's Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company's GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

building cooling↗

2025 Geothermal Drilling Cost Curves Update: Preprint

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy’s Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company’s GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

15 GEOTHERMAL ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Low Cost High-Performance HRE-Free 3-in-1 Electric Drive Unit

The project team completed work to expand upon American Axle & Manufacturing’s (AAM) baseline technology and develop a high-speed, AC induction electric drive unit (EDU) with total direct-oil-cooling and integrated power electronics. The project accelerated advancements in EDU technology by allowing AAM to build upon the progress made in developing the underlying baseline technologies. The following seven improvements to AAM’s baseline technology were implemented in this research and development program: 1) Increased speed (30k RPM) AC induction motor, 2) Silver-sintering of discrete silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFET) to heat sinks, 3) Electrically insulated rotor bars, 4) Optimized lamination steel, 5) EDU-integrated 650VDC inverter package, 6) Over-molded stator with molded liners, and 7) 650VDC power-dense stator design. The successful development of the technology resulted in a meaningful cost reduction for EDU systems in the market. Coupled with falling battery system costs, lower EDU costs will likely accelerate the market acceptance and related production scaling of battery electric vehicles. The objective of this project was to research, develop, and test a Heavy Rare Earth (HRE)-free 3-In-1 electric drive unit (EDU) that has class leading power density and cost. The key technologies to be developed were anticipated to meet or exceed the Department of Energy (DOE) targets of a cost ≤ $\$$7/kilowatt (kW), power density ≥ 12 kW/liter, and operating voltage ≥ 600 VDC.

33 ADVANCED PROPULSION SYSTEMS↗

Screening aqueous organic redox couples for spontaneous hydrogen generation on catalysts

Two low-cost redox couples with near neutral or alkaline pH - 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) and chrome chelated ethylenediaminetetraacetic acid (Cr-EDTA) with ammonia – are identified to generate hydrogen evolution spontaneously on Pt/C catalysts. Cr-EDTA redox couple has two times higher hydrogen evolution rate than that of DHPS, and the charged Cr-EDTA molecules are fully utilized to generate hydrogen gas, while ~ 50% of DHPS molecules are utilized to produce hydrogen spontaneously on Pt/C catalysts. The Cr-EDTA electrolyte enables cost reduction by allowing cheap raw material of Cr and corrosion resistant alloy instead of costly superalloy for catalytic reactor systems. Furthermore, the Cr-EDTA with ammonia as a negolyte for flow batteries was validated to suppress hydrogen evolution side reaction, reach 99% of coulombic efficiency in flow cell operation paired with Fe(CN)6 redox couple near neutral pH.

08 HYDROGEN↗

ROTA-CAP™: An Intensified Carbon Capture System Using Rotating Packed Beds (Final Scientific/Technical Report)

GTI Energy and Carbon Clean Solutions Limited successfully designed, constructed, and operated an integrated ROTA-CAP carbon capture skid. ROTA-CAP™ is a process intensification technology, applied for post-combustion carbon capture, which utilizes the centrifugal forces generated from rotation of rotating packed beds as well as advanced solvents to achieve increased mass transfer rates 1-2 orders of magnitude higher than conventional columns while substantially decreasing footprint. The test skid, which consisted of a dual stage RPB absorber with external interstage cooling and a single stage RPB regenerator, was operated at capacities up to 0.5 tonne/day of CO 2 capture with flue gas concentrations ranging from 4% to 22% CO 2 by vol. CO 2 removal rates greater than 95% were achieved, with CO 2 product purity also exceeding 95% by vol. Over 1,600 hours of operation were accumulated throughout the project, including over 1,000 hours of operation of the with real flue gas containing at least 9.8% CO 2 by vol. The skid was operated continuously for 24 hours per day and 7 days per week over the course of 7 long-term test campaigns, with the campaigns ranging from approximately 2-4 weeks per campaign. A techno-economic analysis was performed, and a cost of capture of $\$$41.18/tonne CO 2 was calculated for the ROTA-CAP process, compared to $\$$45.75/tonne for a Cansolv-based process. These results show a cost reduction of approximately 10% compared to the Cansolv-based process. Although this still exceeds the target cost of capture of $\$$30/tonne specified for this project, GTI expects that the cost of capture can be further reduced through further optimization of the design and technology. GTI also performed an engineering design review to determine the scale-up potential of the technology, with the results of the preliminary assessment indicating that it appears to be feasible to scale up the RPB technology to 4,000 TPD. It was also determined that both horizontal and vertical rotor orientations are feasible, though there are mechanical advantages to the vertical orientation.

20 FOSSIL-FUELED POWER PLANTS↗

Adaptive Framework for Maintenance Scheduling Based on Dynamic Preventive Intervals and Remaining Useful Life Estimation

Data-based prognostic methods exploit sensor data to forecast the remaining useful life (RUL) of industrial settings to optimize the scheduling of maintenance actions. However, implementing sensors may not be cost-effective or practical for all components. Traditional preventive approaches are not based on sensor data; however, they schedule maintenance at equally spaced intervals, which is not a cost-effective approach since the distribution of the time between failures changes with the degradation state of other parts or changes in working conditions. This study introduces a novel framework comprising two maintenance scheduling strategies. In the absence of sensor data, we propose a novel dynamic preventive policy that adjusts intervention intervals based on the most recent failure data. When sensor data are available, a method for RUL prediction, designated k-LSTM-GFT, is enhanced to dynamically account for RUL prediction uncertainty. The results demonstrate that dynamic preventive maintenance can yield cost reductions of up to 51.8% compared to conventional approaches. The predictive approach optimizes the exploitation of RUL, achieving costs that are only 3–5% higher than the minimum cost achievable while ensuring the safety of critical systems since all of the failures are avoided.

Nunes, Pedro (ORCID:0000000180012172)↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

The role of hydrogen as long-duration energy storage and as an international energy carrier for electricity sector decarbonization

With countries and economies around the globe increasingly relying on non-dispatchable variable renewable energy (VRE), the need for effective energy storage and international carriers of low-carbon energy has intensified. This study delves into hydrogen's prospective, multifaceted contribution to decarbonizing the electricity sector, with emphasis on its utilization as a scalable technology for long-duration energy storage and as an international energy carrier. Using Japan as a case study, based on its ambitious national hydrogen strategy and plans to import liquefied hydrogen as a low-carbon fuel source, we employ advanced models encompassing capacity expansion and hourly dispatch. We explore diverse policy scenarios to unravel the timing, quantity, and operational intricacies of hydrogen deployment within a power system. Our findings highlight the essential role of hydrogen in providing a reliable power supply by balancing mismatches in VRE generation and load over several weeks and months and reducing the costs of achieving a zero-emission power system. The study recommends prioritizing domestically produced hydrogen, leveraging renewables for cost reduction, and strategically employing imported hydrogen as a risk hedge against potential spikes in battery storage and renewable energy costs. Furthermore, the strategic incorporation of hydrogen mitigates system costs and enhances energy self-sufficiency, informing policy design and investment strategies aligned with the dynamic global energy landscape.

08 HYDROGEN↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Challenging conventional assumptions in PV: a high-throughput open-air approach to low-cost perovskite module production

Perovskite solar modules (PSMs) offer a promising pathway to low-cost photovoltaics, yet their commercialization is challenged by manufacturing scalability, device uniformity, additive costs, interlayer complexity, and module stability. This study introduces a comprehensive technoeconomic analysis of single junction PSM's and projections for tandem perovskite-Si modules that integrate all materials and manufacturing steps, module performances, projected lifetimes, and manufacturing costs across scales. Here, we highlight an open-air manufacturing approach to fabricate all active layers of serially interconnected PSMs, including electrodes and charge transport layers, enabling high-throughput production without inert or vacuum environments. The analysis reveals two orders of magnitude throughput enhancement and cost reductions of 24% in all-open-air production, escalating to over 60% at 1 GW factory capacity compared to conventional methods. Levelized cost of energy (LCOE) projections for utility-scale installations over 30 years, accounting for module replacement and recycling, demonstrate the potential to achieve the 2030 US target of $0.03 per kWh with realistic 7–11-year PSM lifetimes, outperforming incumbent silicon-based modules. Neither four terminal (4T) nor two terminal (2T) tandem-Si PSMs improve over single junction perovskite or silicon LCOE regardless of higher efficiencies at any modeled lifetime. Addressing PSM technical challenges with a cost-modeling framework guides commercialization efforts and provides a convincing pathway for challenging incumbent Si-based PV.

14 SOLAR ENERGY↗