Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cross-Over Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

Space Station power system issues

Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite.

Giudici, R. J.↗

Acoustic Calibration of the Exterior Effects Room at the NASA Langley Research Center

The Exterior Effects Room (EER) at the NASA Langley Research Center is a 39-seat auditorium built for psychoacoustic studies of aircraft community noise. The original reproduction system employed monaural playback and hence lacked sound localization capability. In an effort to more closely recreate field test conditions, a significant upgrade was undertaken to allow simulation of a three-dimensional audio and visual environment. The 3D audio system consists of 27 mid and high frequency satellite speakers and 4 subwoofers, driven by a real-time audio server running an implementation of Vector Base Amplitude Panning. The audio server is part of a larger simulation system, which controls the audio and visual presentation of recorded and synthesized aircraft flyovers. The focus of this work is on the calibration of the 3D audio system, including gains used in the amplitude panning algorithm, speaker equalization, and absolute gain control. Because the speakers are installed in an irregularly shaped room, the speaker equalization includes time delay and gain compensation due to different mounting distances from the focal point, filtering for color compensation due to different installations (half space, corner, baffled/unbaffled), and cross-over filtering.

Faller, Kenneth J., II↗

Bioavailability of intranasal promethazine dosage forms in dogs

Intramuscular promethazine (PMZ) is used aboard the US Space Shuttle to ameliorate symptoms of space motion sickness. Bioavailability after an oral dose of PMZ during space flight is thought to be impaired because of gastrointestinal disturbances associated with weightlessness and space motion sickness. In an attempt to find an alternative dosage form for use in space, we evaluated two intranasal (i.n.) dosage forms of PMZ in dogs for absorption and bioavailability relative to that of an equivalent intramuscular dose. Promethazine (5 mg kg-1) was administered as two intranasal dosage forms and as an intramuscular (i.m.) dose to three dogs in a randomised cross-over design. Serial blood samples were taken and analysed for PMZ concentrations and the absorption and bioavailability of PMZ were calculated for the three dosage forms. PMZ absorption from the carboxymethyl cellulose microsphere i.n. dosage form was more rapid and complete than from the myverol cubic gel formulation or from an i.m. injection. Bioavailability of the microsphere formulation was also greater than that of the gel formulation (AUC 3009 vs 1727 ng h ml-1). The bioavailability of the two i.n. dosage forms (relative to that of the i.m. injection) were 94% (microsphere) and 54% (gel). The i.n. microsphere formulation of PMZ offers great promise as an effective non-invasive alternative for treating space motion sickness due to its rapid absorption and bioavailability equivalent to the i.m. dose.

NASA Center JSC↗

New Insights on the 7[superscript]Be Cycle in the Ocean

The cosmogenic radionuclide 7[superscript]Be has been applied as a tracer of dynamical processes in the upper ocean and of atmospheric deposition of trace elements at the sea surface. These applications usually assume that 7[superscript]Be is entirely in the dissolved form, and that scavenging and downward export of 7[superscript]Be by settling particles can be neglected. In this work, we explore these assumptions and more generally assess the significance of the 7[superscript]Be activity in the particulate fraction, through the generation of vertical profiles of particulate 7[superscript]Be in the open ocean. From detailed measurements obtained from low-background gamma spectrometers placed in underground facilities, we report vertical profiles of 7[superscript]Be activity in suspended particles (7[superscript]Bep[subscript]) collected in various oceanic regions: the Mediterranean Sea (DYFAMED station), the Indian Sector of the Southern Ocean (station A3-2 from the KEOPS2 cruise), the Sargasso Sea (OFP station), and the subpolar North Atlantic Ocean (GEOVIDE cruise). We find that, in each oceanic region, 7[superscript]Bep[subscript] activities are generally higher in the mixed layer than in the thermocline. They vary in the mixed layer from 3.0 dpm/m3 at DYFAMED to 33.1dpm/m3 at GEOVIDE cross-over station 51/60, i.e., within a range consistent with previous 7[superscript]Bep[subscript] measurements for the open ocean. For the GEOVIDE cruise, the 7[superscript]Bep[subscript] activities measured on different filter types at different depths are corrected for filter offsets derived from multiple 7[superscript]Bep[subscript] measurements at a near-coastal station in the western Mediterranean Sea. We then combine measurements of total 7[superscript]Be activity (Shelley et al., 2017) with our measurements of 7[superscript]Bep[subscript] activity to estimate the solid/solution partitioning of 7[superscript]Be. On average, the particulate fraction would represent 6% of total 7[superscript]Be activity at 5-m water depth (n = 6), 22% at 20 m (n = 2) and 9% at 70 m (n = 3). At GEOVIDE stations, 7[superscript]Bep[subscript] inventories range from 5% to 19% of the total 7[superscript]Be inventories. In the Labrador Sea, the measured 7[superscript]Bep[subscript] inventories are lower than the dry 7[superscript]Be deposition fluxes estimated from aerosol samples collected during GEOVIDE, suggesting that a significant portion of 7[superscript]Bep[subscript] may be removed by sinking particles. The distribution coefficient Kd for 7Be increases with depth, with log10Kd averaging 5.2 ± 0.1 at 5 m to 6.1 ± 0.1 between 70 and 150 m, suggesting that scavenging of dissolved 7[superscript]Be by particles is more pronounced in the thermocline than in the mixed layer when differences in particle concentrations are taken into account. Overall, our study suggests that, at least in some oceanic regions, the removal of 7[superscript]Be by marine particles may be significant and that it may need to be considered in applications of 7[superscript]Be as a tracer of oceanic processes and atmospheric deposition.

Beryllium-7↗

Methods for semi-automated indexing for high precision information retrieval

OBJECTIVE: To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. DESIGN: Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. PARTICIPANTS: Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. MEASUREMENTS: Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. RESULTS: Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). SUMMARY: Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.

Evaluation Studies↗