Investigation of material properties of thermoplastic and thermoset polymer materials at cryogenic temperatures using molecular dynamics
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We demonstrate a silicon photonic transmitter designed for reading out physics detectors in extreme environments. The transmitter operates at room and cryogenic temperature and consists of a micro-ring modulator and a co-designed CMOS serializer and driver.
Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.
Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.
Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.
While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technolo-gies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT [1]) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP [2]) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discus-sions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature [3] [4] [5] and additional lab test-ing (publication in work).
Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.
A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.
This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.
Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.
This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.
This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.
Explore the source record for details and available documents.
During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.
Explore the source record for details and available documents.
Passive thermal control is necessary as space exploration becomes increasingly widespread. Materials with superior optical properties (high solar reflectance and infrared emittance) are critical for passive thermal control because they can reject most of the incident solar radiation and promote thermal emission from cryogenic propellant storage tanks, enabling the extraterrestrial storage of cryogens. We have demonstrated in previous studies that electrospun nanofibers exhibit exceptional optical properties, offering significant benefits for passive radiative cooling in space. Particularly, electrospun polyvinylidene fluoride-co-hexafluoropropylene PVDF-HFP nanofibers demonstrate exceptionally high solar reflectance (>99%) and strong thermal emittance (measured at ~300 K). However, they exhibit nanostructural changes in the presence of atomic oxygen, which is prevalent in Low Earth Orbit. This study focuses on creating a unique blend of polymeric (PVDF-HFP) and ceramic-based (silica) nanofibers by leveraging the chemical stability and atomic oxygen resistance of silica, using the dual electrospinning manufacturing method. This approach aims to preserve the structural properties of the polymeric counterpart without compromising its optical performance, thereby providing an innovative method for manufacturing environmentally resilient passive thermal control nanofibers with desirable optical and thermal control functionalities for extraterrestrial storage of cryogenic propellants.
An analysis was performed to determine the effectiveness of solar reflectors in reducing heat transfer through the insulation of cryogenic fuel tanks located in deep space. A solar reflector, as used herein, is defined as a surface having a ratio of absorptance with respect to solar radiation to hemispherical emittance (α/ϵ) less than 1.0. This analysis considers the effect of surface coatings with α/ϵ values varying from 0.1 to 1.0 when applied to the external surfaces of bulk insulation or multifoil insulation. Results were obtained in terms of heat leak to two cryogenic propellants, liquid hydrogen and liquid oxygen, when stored at Mars, Earth, and Mercury orbital distances from the sun. The results show that, with sufficiently good insulation and low heat leaks to the propellant, α/ϵ is a reasonable criterion of merit for these coatings, but that, at larger heat leaks, consideration of ϵ (or α) is necessary. It was observed that selective finishes of α/ϵ = 0.1 on a given amount of bulk insulation material can reduce the heat leak to 40 to 55 percent of the heat leak obtained when gray finishes are considered. Or, for equivalent heat leaks, a reduction in bulk insulation material thickness of about one-half is possible with high-quality selective finishes (α/ϵ = 0.1) compared with flat reflectors. Larger benefits may be achieved from selective finishes painted on foils; the analysis shows that heat leak may be reduced tenfold for surfaces with an α/ϵ of 0.1 compared with gray surfaces. Again, consideration of equivalent heat leaks indicates that the use of approximately 10 times fewer foils of emissivity 0.05 is possible when spectrally selective surfaces are employed. The present state of the art in achieving such surfaces is also briefly reviewed.