Search NASASearch

SEARCH · Search NASA

Results for “Cryogenics & vacuum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

450 records · Page 3

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting

Swamp Works Regolith Compaction Technologies

While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technolo-gies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT [1]) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP [2]) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discus-sions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature [3] [4] [5] and additional lab test-ing (publication in work).

vibration

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

A Cryogenic Seven-Element HEMT Front End for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

J Bowen

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

two-phase flow

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing

Investigating Dual Electrospinning as a Means of Enhancing Passive Thermal Control Coatings for Cryogenic Propellant Storage in Extraterrestrial Environments

Passive thermal control is necessary as space exploration becomes increasingly widespread. Materials with superior optical properties (high solar reflectance and infrared emittance) are critical for passive thermal control because they can reject most of the incident solar radiation and promote thermal emission from cryogenic propellant storage tanks, enabling the extraterrestrial storage of cryogens. We have demonstrated in previous studies that electrospun nanofibers exhibit exceptional optical properties, offering significant benefits for passive radiative cooling in space. Particularly, electrospun polyvinylidene fluoride-co-hexafluoropropylene PVDF-HFP nanofibers demonstrate exceptionally high solar reflectance (>99%) and strong thermal emittance (measured at ~300 K). However, they exhibit nanostructural changes in the presence of atomic oxygen, which is prevalent in Low Earth Orbit. This study focuses on creating a unique blend of polymeric (PVDF-HFP) and ceramic-based (silica) nanofibers by leveraging the chemical stability and atomic oxygen resistance of silica, using the dual electrospinning manufacturing method. This approach aims to preserve the structural properties of the polymeric counterpart without compromising its optical performance, thereby providing an innovative method for manufacturing environmentally resilient passive thermal control nanofibers with desirable optical and thermal control functionalities for extraterrestrial storage of cryogenic propellants.

Chieloka Ibekwe

Performance of Solar Reflectors When Applied to Storage of Cryogenic Propellants in Space

An analysis was performed to determine the effectiveness of solar reflectors in reducing heat transfer through the insulation of cryogenic fuel tanks located in deep space. A solar reflector, as used herein, is defined as a surface having a ratio of absorptance with respect to solar radiation to hemispherical emittance (α/ϵ) less than 1.0. This analysis considers the effect of surface coatings with α/ϵ values varying from 0.1 to 1.0 when applied to the external surfaces of bulk insulation or multifoil insulation. Results were obtained in terms of heat leak to two cryogenic propellants, liquid hydrogen and liquid oxygen, when stored at Mars, Earth, and Mercury orbital distances from the sun. The results show that, with sufficiently good insulation and low heat leaks to the propellant, α/ϵ is a reasonable criterion of merit for these coatings, but that, at larger heat leaks, consideration of ϵ (or α) is necessary. It was observed that selective finishes of α/ϵ = 0.1 on a given amount of bulk insulation material can reduce the heat leak to 40 to 55 percent of the heat leak obtained when gray finishes are considered. Or, for equivalent heat leaks, a reduction in bulk insulation material thickness of about one-half is possible with high-quality selective finishes (α/ϵ = 0.1) compared with flat reflectors. Larger benefits may be achieved from selective finishes painted on foils; the analysis shows that heat leak may be reduced tenfold for surfaces with an α/ϵ of 0.1 compared with gray surfaces. Again, consideration of equivalent heat leaks indicates that the use of approximately 10 times fewer foils of emissivity 0.05 is possible when spectrally selective surfaces are employed. The present state of the art in achieving such surfaces is also briefly reviewed.

Propellant Storage

In-Space Laser Forming Simulated Under Thermal Vacuum (TVAC) Conditions

NASA Marshall Space Flight Center is investigating laser forming under thermal vacuum conditions representative of the space environment through a partnership with the DARPA NOM4D program. The thermal gradient mechanism (TGM) is used to bend a metal sheet towards the laser optics. Laser equipment and process parameters are being optimized for thermal vacuum conditions. Such conditions are representative of the extreme cold and hot temperatures and high vacuum that exist on orbit or on the lunar surface. in situ photogrammetry and thermography assess the bend/counterbend and elucidate the TGM in thermal vacuum. Structured light scanning and metallography after bending reveal the macroscopic and microscopic structure after TGM.

thermal vacuum

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen