At least 55 records · Page 3

Graphene as reusable substrate for bialkali photocathodes

Bialkali photocathodes, such as cesium potassium antimonide (CsK 2 Sb), can generate a high-brightness electron beam using a high-power green laser. These photocathode materials have potential applications in advanced accelerators and electron microscopes. It is known that the quantum efficiency (QE) of these photocathodes is affected severely by their substrates; however, reusability of the substrates is not well known. Here, we use graphene, silicon (Si), and molybdenum (Mo) substrates to evaluate the effects of substrates on the QE of redeposited CsK 2 Sb photocathodes after thermal cleanings. We found the QE of CsK 2 Sb photocathodes redeposited on a graphene substrate after a thermal cleaning at 500 °C remained largely unchanged. On the other hand, the QE of redeposited photocathodes on Si and Mo substrates after thermal cleaning at the same temperature decreased drastically. We used X-ray photoelectron spectroscopy (XPS) to quantitatively evaluate the residues of photocathodes after thermal cleaning at 400 °C and 500 °C. We found that the Sb, K, and Cs are removed by thermal cleaning at 500 °C for the graphene substrate, but all or the majority of these elements remained on the Si and Mo substrates. The results were consistent with our density functional theory (DFT) calculations for the case of Si, which we investigated. Furthermore, our angle-resolved photoemission spectroscopy (ARPES) on graphene indicated that its intrinsic electronic structure is preserved after photocathode deposition and thermal cleaning at 500 °C. Hence, we attributed the difference in amount of photocathode residue to the unique dangling-bond- free surface of inert graphene. Our results provide a foundation for graphene-based reusable substrates for high-QE semiconductor photocathodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature Effect of Cesium Exchange onto Crystalline Silicotitanate in AP-107 and AP-105 Hanford Tank Wastes and Two Simulants

Washington River Protection Solutions, LLC (WRPS) is charged with the development of the Tank Side Cesium Removal (TSCR) system to process Hanford tank waste supernates in preparation for vitrification. In addition to a filtration step, TSCR will remove cesium (Cs) using ion exchange columns filled with crystalline silicotitanate (CST) ion exchange media. CST is produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for the TSCR system limits a single column loading to 141,600 Ci 137 Cs. Given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of 596 L (157.5 gal) in a TSCR column, this equates to 0.10 mmole Cs per g CST (Cs distribution coefficient, K d , 1400 mL/g). Factors that influence Cs uptake by CST include (but are not limited to) (1) CST production (lot-to-lot variations), (2) contact temperature, (3) contact duration, (4) competitors in the tank waste feed, (5) anionic composition of the tank waste feed, and (6) the 137 Cs isotopic mass fraction (differs slightly among tank wastes and decreases with time).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Results from November 2021 Qualification Samples for Tank Closure Cesium Removal 1A (TCCR 1A)

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 1 for processing through the TCCR 1A unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Results from Batch 1 Qualification Samples for Tank Closure Cesium Removal 1A (TCCR 1A)

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each waste supernate batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 1 for processing through the TCCR 1A unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cs absorption capacity and selectivity of crystalline and amorphous Hf and Zr phosphates

Removal of radioactive Cs from sodium-rich solutions is a technical challenge that goes back to post World War II nuclear waste storage and treatment; and interest in this topic was reinvigorated by the Fukushima-Daiichi nuclear power plant disaster, 10 years ago. Since the 1960's there has been considerable focus on layered Zr phosphates as robust inorganic sorbents for separation of radionuclides such as Cs. Here we present synthesis and characterization, and direct comparison of Cs sorption capacity and selectivity of four related materials: 1) crystalline α-Zr phosphate and α-Hf phosphate, and 2) amorphous analogues of these. Powder X-ray diffraction, thermogravimetry, solid-state 31P magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy, and compositional analysis (inductively coupled plasma optical emission spectroscopy and mass spectroscopy, ICP OES and ICP MS) provided formulae; respectively M(HPO4)2∙1H2O and M(HPO4)2∙4H2O (M = Hf, Zr) for crystalline and amorphous analogues. Maximum Cs loading, competitive Cs-Na selectivity and maximum Cs-Na loading followed by the above characterizations plus 133Cs MAS-NMR spectroscopy revealed that amorphous analogues are considerably better Cs-sorbents (based on maximum Cs-loading and selectivity over Na) than the well-studied crystalline Zr-analogue. Additionally, crystalline α-Hf phosphate is better Cs-sorbent than crystalline α-Zr phosphate. All these studies consistently show that Hf phosphate is less crystallize than Zr phosphate, when obtained under similar or identical synthesis conditions. We attribute this to lower solubility of Hf phosphate compared to Zr phosphate, preventing ‘defect healing’ during the synthesis process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

Sorbmatech{sup R}Cs, an Innovative Highly Selective Cs Sorbent for Wastewater Decontamination - 20065

The treatment of radioactive wastewater from the operating nuclear industry (energy production, reprocessing of spent fuel, decommissioning of shut-down facilities, etc.) or in case of incidental or accidental situation (such as Fukushima Daichii NPP accident) is an important issue requiring constant improvement of the technologies and techniques used to prevent radioactive releases into the environment and/or to reduce the production of secondary waste. CEA, Orano and CTI are collaborating since 2014, with the support of the French government's program 'investments for the future', to develop Sorbmatech{sup R}Cs, an innovative and patented selective sorbent (Grandjean and Barre 2014) to deal with the removal of radioactive {sup 137}Cs, one of the most hazardous isotope to be managed in nuclear waste, highly efficient either in agitated reactor or in column process. Sorbmatech{sup R}Cs sorbent consists of mesoporous silica particles loaded with potassium-copper hexacyanoferrate nanoparticles (KCu-HCF). This peculiar structure enables much faster sorption kinetics compared to denser crystalline structures, such as Silicotitanate or Zeolite sorbents, whose drawback consists in hindering the diffusion process through the material, and whose larger sorbent particles slow down the ion exchange process. The equilibrium of Sorbmatech{sup R}Cs is reached in few minutes, even at high flow rates in a fixed-bed column process (up to 10 m.h{sup -1} Darcy velocity) with low drop pressure. Moreover, Sorbmatech{sup R}Cs can be used over a wide pH range from 2 to 10 and has a very high selectivity towards {sup 137}Cs even in brine solution (saline, mineral or sea water). This new sorbent also has a K{sub d} higher than 10{sup 5} mL.g{sup -1} depending on the salinity of the wastewater, enabling a highly efficient removal of Cs trace in radioactive wastewater compared to Cs selective sorbent such as Zeolites and Silicotitanates. Its radiological resistance enables the treatment of high, medium and low activity wastewater. The CEA-Orano-CTI/ALSYS partnership leads to the development of a simple and low-cost synthetic route, which demonstrated large-scale manufacturing of the product on a batch of 100 kg. Two products have been developed and are ready for short run market introduction so far with grain size well adapted either for column processes or agitated reactors.. Finally, the industrial implementation has been studied and largely benefits from the properties of the sorbent. Indeed, its high sorption kinetics enable high flow rates resulting in a decrease of operation times, unit sizes, and volumes of secondary waste produced. Moreover, Sorbmatech{sup R}Cs is designed to be combined into a full and integrated solution, ranging from preliminary optimization of operating conditions through numerical dimensioning model, industrial implementation and treatment of the wastewater (through cartridge or preconditioned columns systems developed thanks to Orano's extensive expertise), to long-term stabilization of generated waste (under progress). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion-Exchange Modeling of Crystalline Silicotitanate for Cesium Removal - 20283

The Tank Closure Cesium Removal (TCCR) system is a Savannah River Site (SRS) demonstration 'at-tank' process designed to remove {sup 137}Cs from the high-level aqueous tank waste so that the decontaminated solution can be disposed as low-level waste. Cesium is removed by ion exchange (IX) columns using engineered IONSIV{sup TM} R9120-B form of the Crystalline Silicotitanate (CST) media. The TCCR system is deployed at Tanks 10 and Tank 11 in the SRS H Tank Farm. Water is added to the salt-cake in Tank 10 H to dissolve it. The dissolved salt solution waste is pumped out of Tank 10H (feed tank), through filters and IX columns. The decontaminated salt solution is transferred to Tank 11 (receipt tank), and on to Tank 50H for final disposal in the Saltstone Production Facility. The current TCCR can accommodate lead-lag (two-column) or lead-lag-guard (three-column) configurations to optimize media utilization and achieve the target decontamination. To assist the TCCR operations, a parametric study was conducted to evaluate the impact of different parameters (e.g., column configurations (single column, two columns or three columns in series), waste characteristics, operating temperature, process flow rate, CST average particle size) on the IX column performance including CST bed utilization. The initial results indicate that the IX column performance is improved at slower process flow rate, at lower operating temperature, and with smaller CST average particle size. Multi-column configurations are recommended, because the single-column configuration does not utilize CST bed effectively. This paper demonstrates the versatility of the ion exchange modeling to evaluate the effects of CST characteristics and operational parameters on IX column performances. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrochemical CO2 concentration for the Space Station Program

Under the sponsorship of NASA, Electrochemical Carbon Dioxide (CO2) Concentration EDC technology has been developed that removes CO2 continuously or cyclically from low CO2 partial pressure (400 Pa) atmospheres with the performance and operating characteristics required for Space Station applications. The most recent advancement of this technology is the development of an advanced preprototype subsystem, the CS-3A, to remove the metabolic CO2 produced by three persons from the projected Space Station atmosphere. This paper provides an overview of EDC technology, shows how it is ideally suited for Space Station application, and presents technology enhancements that will be demonstrated by the CS-3A subsystem development program.

Lance, N.↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disulfonamide Ligands as f-Element Extractants from Alkaline High-Level Waste

Almost 100 million gallons of high level waste (HLW) has been generated from defense reprocessing programs to support nuclear weapons production. HLW is currently stored at the Hanford and Savannah River Sites (SRS) [1]. It contains radioactive components, such as {sup 137}Cs, {sup 99}Tc and {sup 90}Sr, as well as large amounts of non-radioactive species, including solvated cations and insoluble metal hydroxides. HLW has high concentration of soluble hydroxides ([OH{sup -}] = 2 M at SRS [2]), complexing inorganic anions ([NO{sub 3}{sup -}] ∼ 0.65 - 3.7 M at SRS [2]) and a high ionic strength. Even though the majority of actinide component in alkaline HLW is precipitated, studies of An(III) and Ln(III) complexation in highly alkaline solutions in the presence of high nitrate concentrations have showed that soluble nitrate complexes can be formed [3]. The current treatment of HLW at SRS currently consists of two processes: The Actinide Removal Process (ARP) and the Next-Generation Caustic-Side Solvent Extraction process (NG-CSSX). Strontium and actinides are removed by sorption on monosodium titanate through the Actinide Removal Process (ARP) commonly referred to as the alpha-strike step [4]. Then, cesium is selectively extracted from the alkaline media via the Caustic-Side Solvent Extraction (CSSX) process [5]. The CSSX solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix containing i) a solvent modifier (alkylphenoxy alcohol) which increases extractant solubility and prevents third phase formation, and ii) a suppressor (trioctylamine or guanidine) - that mitigates surfactant effects. The CSSX process removes {sup 137}Cs selectively and rapidly, yet the post- CSSX aqueous stream may still contain high amounts of An, thus requiring a second ARP treatment (referred to as 'alpha-finishing') for some tanks. Despite the success of the ARP process in removing Sr and An, it often represents the kinetic bottleneck of integrated processing, as it is slower than solvent extraction. Understanding the complexation of actinides by organic ligands that are compatible with the CSSX process could eventually lead to a combined caustic-side Cs/Sr/actinide extraction process with better economics due to a reduced amount of monosodium titanate and/or a shorter required contact time with titanate during ARP. This would ensure a low-activity waste (LAW) stream with no actinides without additional ARP processing post-CSSX. Disulfonamides were studied for extraction of Sm(III) from alkaline aqueous media of pH 10-14 into dichloromethane. Up to 82% of Sm(III) was extracted from solutions of pH 12.5 -13.5 and up to 84% from solutions of pH 10.5 - 11.5. These results show some resemblance with Am extraction results by calixarene ligands previously reported [10]. Kinetic studies demonstrated that even 5 min is enough to complete stripping, whereas extraction is time-limiting process and requires up to 20 h for efficient removal of Sm(III) from alkaline aqueous media. Determination of composition of complexes in solution after extraction by the equilibrium shift method showed a 1:1 Sm(III):dsa-2 complexation ratio for the extracted species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of High Specific Activity Fission Products from Uranyl Sulfate Waste Solutions

The Savannah River National Laboratory (SRNL) is currently providing support to SHINE Medical Technologies (SHINE) which plans to deploy a low energy, accelerator-based neutron source to fission low enriched U in a uranyl sulfate target solution for 99 Mo production. The 99 Mo is initially separated from the fission products and target solution by an extraction column. Subsequent washing of the column will generate waste solutions containing residual U and fission product activity. A small number of high specific activity fission products (e.g., 90 Sr, 137 Cs, and 144 Ce) in these streams will likely control the classification of the low level waste (LLW). If a sufficient amount of the high specific activity isotopes are separated from the SHINE waste streams and concentrated into a waste form, it would be possible to treat a majority of the wash solutions from the column operations as a lower class of LLW (Class A versus Class B or C or Class B versus Class C). The high specific activity fission product elements could then be dispositioned as a much smaller volume of waste rather than requiring the disposal of the entire waste stream at the higher waste classification. The Savannah River Site (SRS) has experience with using monosodium titanate (MST) and crystalline silicotitanate (CST) to remove Cs and Sr from high salt content waste solutions generated during the reprocessing of nuclear fuels and targets. Both of these materials have worked very well for their intended purposes at the SRS where the fission product elements are removed from highly alkaline waste. On the other hand, SHINE waste streams from the extraction column contain H 2 SO 4 which makes the solution acidic. Additionally, the SRS waste streams do not contain other fission product elements such as transition metals or lanthanides because they precipitate upon neutralization of the SRS waste and are not present in the supernate which is dispositioned as LLW following treatment. As such, there are inherent differences between SHINE and SRS waste treatment strategies. Savannah River National Laboratory was tasked with performing scoping studies to see if MST and CST would remove Sr, Cs, and Ce from an acidic mixed metal simulant solution. Batch contact experiments were performed using MST and two CST type materials. The MST material is a 15 wt % powder in 0.15 M NaOH slurry. The MST showed low adsorption for elements of interest from acidic solution. Furthermore, the powder size makes MST non-ideal for column operations. A CST IE-911 ion exchange material had high Cs adsorption, moderate Sr, and marginal Ce adsorption. Based on adsorption of all species, the ion exchange capacity was found to be 0.032 meq/mL. A bench-top column experiment to measure elemental breakthrough curves was performed using CST IE-911 where chromatographic separations of the mixed simulant were expected to occur. While most elements behaved as expected, the lanthanide series, containing Ce, broke though the column earlier than expected. The second CST material, CST R9120, displayed high adsorption for all elements in the acidic mixed simulant solutions in a batch contact study, and had a calculated loading capacity of 0.091 meq/mL. Future studies to develop a waste treatment flowsheet should focus on CST R9120 to treat SHINE waste solutions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regenerable CO2 collection for spacecraft application

The design of the CS-3, a three-person capacity preprototype CO2 collection subsystem, is described. It is noted that the function of the CS-3 is to remove metabolically produced CO2 from the Spacelab cabin to maintain atmospheric pCO2 at 400 Pa or less. Results are presented of an extensive parametric/endurance test program characterizing the subsystem's performance. The results demonstrate the suitability of the electrochemical depolarized CO2 concentration concept for possible use in the Space Operations Center. The CS-3 is found to meet or exceed all Regenerative Life Support Evaluation requirements. Specifically, the 0.13 cu m, 46 kg subsystem is able to remove CO2 at an equivalent rate of 3.4 persons from an air stream having a pCO2 of 400 Pa.

Lance, N., Jr.↗

Porous Semiconducting K–Sn–Mo–S Aerogel: Synthesis, Local Structure, and Ion-Exchange Properties

Chalcogenide-based aerogels are emerging porous semiconducting nanomaterials that appeal to applications in clean energy and the environment. Here, we report a novel gel, potassium–tin–molybdenum–sulfides (KTMS), that integrates the electrostatically bound K + ions in the covalent network of Sn–Mo–S. Its gelation requires a concurrent reduction of Mo 6+ → Mo 4+/5+ and the oxidation of S 2– → Sn – (n ≈ 1) and Sn 2+ → Sn 4+ . KTMS is an amorphous semiconductor showing quantum confinement effects on band gap energies, 2.1 → 1.4 → 0.9 eV for its wet- → aero- → xerogels. Synchrotron X-ray pair distribution function (PDF) and extended X-ray absorption fine structure (EXAFS) revealed a complex local structure of KTMS consisting of molecular Mo 2 (S 2 ) 6 and Mo 3 S(S 2 ) 6 clusters. In addition, the Sn–S coordination is related to crystalline Na4Sn3S8 and SnS2. KTMS also demonstrated the removal of the radionuclides of Cs + , Sr 2+ , and UO 2 2+ from ppm to ppb levels with distribution constants (Kd) up to ≥104 mL/g. Notably, despite the lack of atomic periodicity in the amorphous KTMS, the K+ ion is ion-exchangeable with chemically diverse Sr 2+ , Cs + , and UO 2 2+ in aqueous solutions; especially the ion-exchange properties of Sr 2+ and UO 2 2+ ≡(O=U=O) 2+ is not known to any chalcogels known to date. The sequestration of Cs + and Sr 2+ was achieved by the exchange of K + in the amorphous KTMS, and the removal of [O=U 6+ =O] 2+ synergistically involves surface sorption via -S····U 6+ =O 2 2+ covalent interactions and ion-exchange via the hard–soft Lewis acid–base paradigm. Overall, cooperative roles played by the diverse bonding motifs, surface-exposed Lewis basic frameworks, and polarizability of the (poly)sulfides make it an exceptional adsorbent for chemically diverse radioactive species. This finding will guide the design of superior sorbents for chemically distinct metal ion separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗