DARHT Radiographic Grid Scale Correction

Recently it became apparent that the radiographic grid which has been used to calibrate the dimensional scale of DARHT radiographs was not centered at the location where the objects have been centered. This offset produced an error of 0.188% in the dimensional scaling of the radiographic images processed using the assumption that the grid and objects had the same center. This paper will show the derivation of the scaling correction, explain how new radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic image processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

Retuning the DARHT Axis-II Linear Induction Accelerator

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. The Axis-II 1.7-kA, 1600-ns beam pulse is transported through the LIA by the magnetic field from 91 solenoids as it is accelerated to ~16.5 MeV. The magnetic field produced by the solenoids and 80 steering dipole pairs for a given set of magnet currents is known as the “tune” of the accelerator [1]. From June, 2013 through September, 2014 a single tune was used. This tune was based on measurements of LIA element positions made over several years [2], and models of solenoidal fields derived from actual field measurements [3] [4]. Based on the focus scan technique, changing the tune of the accelerator and downstream transport had no effect on the beam emittance, to within the uncertainties of the measurement. Beam sizes appear to have been overestimated in all prior measurements because of the low magnification of the imaging system. This has resulted in overestimates of emittance by ~50%. The high magnification imaging should be repeated with the old tune for direct comparison with the new tune. High magnification imaging with the new accelerator tune should be repeated after retuning the downstream to produce a much more symmetric beam to reduce the uncertainty of this measurement. Thus, these results should be considered preliminary until we can effect a new tune to produce symmetric spots at our imaging station, for high magnification images.

43 PARTICLE ACCELERATORS↗

Beam-dynamics codes used at DARHT

Several beam simulation codes are used to help gain a better understanding of beam dynamics in the DARHT LIAs. The most notable of these fall into the following categories: for beam production – Tricomp Trak orbit tracking code, LSP Particle in cell (PIC) code, for beam transport and acceleration – XTR static envelope and centroid code, LAMDA time-resolved envelope and centroid code, LSP-Slice PIC code, for coasting-beam transport to target – LAMDA time-resolved envelope code, LSP-Slice PIC code. These codes are also being used to inform the design of Scorpius.

43 PARTICLE ACCELERATORS↗

Modeling blur in various detector geometries relevant to DARHT

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for MeV radiography which are applicable to DARHT. Segmented scintillator detectors, where low Z scintillators combined with a high-Z metal matrix, are designed such that the resolution increases with increasing metal fraction. The combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution which degrades with plate number. Excellent agreement between simulation and experimental modulation transfer functions for select detector geometries was found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-ray spectrometer design for warm dense plasma measurements on DARHT Axis-I

A preliminary design study is being performed on a soft X-ray spectrometer to measure K-shell spectra emitted by a warm dense plasma generated on Axis-I of the Dual-Axis Radiographic Hydrodynamic Testing (DARHT) facility at Los Alamos National Laboratory. The 100-ns-long intense, relativistic electron pulse with a beam current of 1.7 kA and energy of 19.8 MeV deposits energy into a thin metal foil heating it to a warm dense plasma. The collisional ionization of the target by the electron beam produces an anisotropic angular distribution of K-shell radiation and a continuum of both scattered electrons and Bremsstrahlung up to the beam energy of 19.8 MeV. The principal goal of this project is to characterize these angular distributions to determine the optimal location to deploy the soft X-ray spectrometer. In addition, a proof-of-principle design will be presented. The ultimate goal of the spectrometer is to obtain measurements of the plasma temperature and density to benchmark equation-of-state models of the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aberrations and Emittance Growth in the DARHT 2nd Axis Downstream Transport

The emittance of the DARHT 2 nd Axis has been inferred from solenoid scans performed in the downstream transport (DST) region using a short kicked pulse. The beam spot size is measured by viewing optical transition radiation (OTR) in the near field as a function of the field (current) of a solenoid magnet (S4). The imaging station containing the OTR target is located about 100 cm downstream of the solenoid magnet. The emittance is then inferred using a beam optics code such as LAMDA or XTR by fitting the data to initial conditions upstream of the S4 solenoid magnet. The initial conditions are the beam size, beam convergence and emittance. The beam energy and current are measured. In preparation for a solenoid scan, the magnets upstream of the solenoid are adjusted to produce a round beam with no beam losses due to scraping in the beam tube. This is different from the standard tune in which the beam tune is adjusted to suppress the effects of ions and rf in the septum dump. In this standard tune, approximately 10% of the beam is lost due to scraping as the beam enters the small 3.75” ID beam tube after the septum. The normalized emittance inferred from recent solenoid scans typically ranges from 600 to 800 π(mm-mrad). This larger beam size increases the sensitivity to any non-linear fields in the Collins quadrupoles that are mounted along the small diameter beam tube. The primary magnet used to adjust the beam size in this region is the S3 solenoid magnet. Measurements made of the beam shape as the beam size was decreased showed significant structure consistent with non-linear fields. Using the measured magnetic fields in the Collins quadrupoles including higher order multipoles, the beam transport through the Collins quadrupoles is simulated and compared to the observed OTR images. The simulations are performed using the beam optics codes TRANSPORT [1] and TURTLE [2]. Estimates of the emittance growth and beam losses are made as a function of the S3 magnet setting. The increase in the spot size on the x-ray production target resulting from this emittance growth is examined for different DST tunes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Engineering Analysis of the DARHT 3685 6-ft Confinement Vessel

An engineering analysis of the DARHT 3685 confinement vessel was performed using the Lagrangian finite element code, ABAQUS, and the shock physics code CTH. The ABAQUS analysis indicates that, for a non-uniform applied pressure loading with peak pressures approaching 300 000 psi near the top and bottom centerline of the vessel1, several of the bolts connecting the top cover to the top nozzle will plastically deform, possibly leading to progressive failure of the remaining bolts. A pure Eulerian analysis indicates that the minimum fragment energy for rupture of the 2.5- inch wall is approximately 50 kJ. Lastly, recommendations for use of combined Eulerian and Lagrangian techniques are discussed which might enhance future vessel analysis activities.

42 ENGINEERING↗

Radiographic Detectors for DARHT and ECSE

Presentation Introduction: Moderate to thick object radiographic detectors have been in use at LANL’s DARHT facility for nearly two decades. They serve as the primary diagnostic for gas cavity hydrodynamic experiments; Can reduce the design constraints of the source; Performance is dependent on the source and environmental characteristics; Bremsstrahlung target interactions; Bremsstrahlung energy spectrum; Scattered radiation; Temperature, humidity etc.; The Scorpius detector design aims to improve the performance of existing detector designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiographic Magnification Differences Due To Grid Placement at DARHT

In 2015, it became apparent that the radiographic grid, which has been used to calibrate the dimensional scale of DARHT radiographs, was not centered at the location where the objects have been centered along the beamline. Instead of the grid center being placed at 133.0 cm, the grid downstream face was placed at this location, putting the grid center at 132.75 cm. This o set produced an error of 0.188% in the dimensional scaling of the radiographic images processed, using the assumption that the grid and objects had the same center. The Air Force Target (AFT) had the same holder as the grid, while the Circular Resolution Target (CRT) used a holder that correctly placed the object center at 133.0 cm. These erroneous holders were used until October 2015. Starting in November 2015, new holders were used that placed all static target objects in the correct location, with their center at 133.0 cm. This paper will show the derivation of the scaling correction, explain how old radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic images processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

DARHT Axis II Cell Solenoid Magnet Shunt Resistance

DARHT Axis-II cell solenoid magnets have exhibited significant degradation since initial manufacture. A recent redesign of these magnets has provided an opportunity to revisit the dielectric performance to ensure high quality magnets are obtained. Magnet test specifications are shown to be consistent with those recommended in the literature and in use by practicing magnet engineers. A dielectric analysis of the coil reveals that the epoxy layer thickness and integrity are critical to meeting the required performance but are not adequately controlled in the present specification. Remedies to the coil fabrication process are provided.

42 ENGINEERING↗

A Correct Flat Field Model For DARHT

The forward modeling approach has been utilized to obtain the density distribution during dynamic radiographic experiments using the Bayesian Inference Engine (BIE) at the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) for over two decades. The forward modeling approach attempts to incorporate all of the known physics to obtain the transmission, from an unknown density field. The density field is then optimized in an attempt to match the flat-fielded radiographic image using a Chi-squared comparison. A depiction of the forward modeling approach implemented in the BIE is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

DARHT Overview [Slides]

DARHT is a key facility for Stockpile Stewardship. Dual Axis Radiographic Hydrodynamic Test Facility - World-class X-ray radiography for dynamic non-nuclear tests.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗