Search NASA⌕ Search

SEARCH · Search NASA

Results for “DROPLETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A simple technique to reduce evaporation of crystallization droplets by using plate lids with apertures for adding liquids

This article describes the use of evaporation control lids that are fitted to crystallization plates to improve the reproducibility of trials using as little as 5 nl. The plate lids contain apertures which are large enough for the transfer of protein containing droplets, but small enough to greatly reduce the rate of evaporation during the time needed to prepare the plate. A method is described for using plate lids to reduce evaporation in low-volume vapor-diffusion crystallization experiments. The plate lids contain apertures through which the protein and precipitants were added to different crystallization microplates (the reservoir was filled before fitting the lids). Plate lids were designed for each of these commonly used crystallization microplates. This system minimizes the dehydration of crystallization droplets containing just a few nanolitres of protein and precipitant, and results in more reproducible diffraction from the crystals. For each lid design, changes in the weight of the plates were used to deduce the rate of evaporation under different conditions of temperature, air movement, droplet size and precipitant. For comparison, the state of dehydration was also visually assessed throughout the experiment. Finally, X-ray diffraction methods were used to compare the diffraction of protein crystals that were conventionally prepared against those that were prepared on plates with plate lids. The measurements revealed that the plate lids reduced the rate of evaporation by 63–82%. Crystals grown in 5 nl drops that were set up with plate lids diffracted to higher resolution than similar crystals from drops that were set up without plate lids. The results demonstrate that plate lids can be instrumental for improving few-nanolitre crystallizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bismuth nano-droplets for group-V based molecular-beam droplet epitaxy

Self-assembly of bismuth droplets at nanoscale on GaAs(100) surface using molecular beam epitaxy was demonstrated. Fine control of density and size was achieved by varying growth temperature and total bismuth deposition. Droplet density was tuned by roughly 3 orders of magnitude, and the density-temperature dependence was found to be consistent with classical nucleation theory. These results may extend the flexibility of droplet epitaxy by serving as templates for group V based droplet epitaxy, which is in contrast to conventional group III based droplet epitaxy and may encourage nanostructure formation of bismuth-containing materials.

36 MATERIALS SCIENCE↗

Comprehensive Analysis of the Relative Dispersion of Droplet-Size Distributions and Their Relationships to Key Physical Fog Processes Under Different Aerosol Conditions and Evolutionary Stages

The relative dispersion of cloud and fog droplets has significant impacts on aerosol indirect effects, radiative transfer, and microphysical processes. However, previous studies have been mostly concerned with clouds, with limited studies on fog, particularly those that examine the combined influences of all key physical processes and their roles during fog evolution. As such, this study aims to conduct a comprehensive investigation by examining the relationships between relative dispersion and other microphysical variables, as well as the underlying microphysical and dynamic processes, based on field fog campaigns in polluted and clean conditions. In polluted fog, droplet concentrations are higher, leading to smaller droplets and increased dispersion. The correlation between dispersion and droplet volume-mean radius is positive in the polluted fog, but shifts to negative in clean fog. Here, we attribute the difference to various microphysical processes like aerosol activation, condensation, collision-coalescence, and entrainment-mixing. In polluted fog, high aerosol concentrations, low supersaturations, and strong turbulence (entrainment-mixing) provide suitable conditions for the simultaneous occurrence of droplet condensation and aerosol activation, resulting in a positive correlation between dispersion and volume-mean radius, especially during the fog formation stage. In contrast, during the mature stage in clean fog, condensation is dominant with weak aerosol activation leading to a negative correlation between relative dispersion and volume-mean radius. The collision-coalescence process is more active in the mature stage, increasing radii and leading to the negative correlation between dispersion and volume-mean radius. This result sheds new light on understanding the relative dispersion and mechanisms in fog under different aerosol backgrounds.

54 ENVIRONMENTAL SCIENCES↗

Development of a droplet breakup model considering aerodynamic and droplet collision effects

A model is currently under development to predict the occurrence and outcome of spray droplet breakup induced by aerodynamic forces and droplet collisions. It is speculated that these phenomena may be significant in determining the droplet size distribution in a spray subjected to acoustic velocity fluctuations. The goal is to integrate this breakup model into a larger spray model in order to examine the effects of combustion instabilities on liquid rocket motor fuel sprays. The model is composed of three fundamental components: a dynamic equation governing the deformation of the droplet, a criterion for breakage based on the amount of deformation energy stored in the droplet and an energy balance based equation to predict the Sauter mean diameter of the fragments resulting from breakup. Comparison with published data for aerodynamic breakup indicates good agreement in terms of predicting the occurrence of breakup. However, the model significantly over predicts the size of the resulting fragments. This portion of the model is still under development.

Wert, K. L.↗

Japan's research on droplet and droplet array combustion

In Japan, the ignition and combustion of the droplet and droplet array have been investigated by using microgravity condition. This is the short introduction of those studies; interactive combustion of two droplets, ignition experiment on droplet array, and microexplosion behavior of an emulsified fuel droplet.

Kono, Michikata↗

Two-center three-electron bonding in ClNH{sub 3} revealed via helium droplet infrared laser Stark spectroscopy: Entrance channel complex along the Cl + NH{sub 3} → ClNH{sub 2} + H reaction

Pyrolytic dissociation of Cl{sub 2} is employed to dope helium droplets with single Cl atoms. Sequential addition of NH{sub 3} to Cl-doped droplets leads to the formation of a complex residing in the entry valley to the substitution reaction Cl + NH{sub 3} → ClNH{sub 2} + H. Infrared Stark spectroscopy in the NH stretching region reveals symmetric and antisymmetric vibrations of a C{sub 3v} symmetric top. Frequency shifts from NH{sub 3} and dipole moment measurements are consistent with a ClNH{sub 3} complex containing a relatively strong two-center three-electron (2c–3e) bond. The nature of the 2c–3e bonding in ClNH{sub 3} is explored computationally and found to be consistent with the complexation-induced blue shifts observed experimentally. Computations of interconversion pathways reveal nearly barrierless routes to the formation of this complex, consistent with the absence in experimental spectra of two other complexes, NH{sub 3}Cl and Cl–HNH{sub 2}, which are predicted in the entry valley to the hydrogen abstraction reaction Cl + NH{sub 3} → HCl + NH{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Screening of the Suzuki Cross-Coupling Reaction Using Desorption Electrospray Ionization in High-Throughput and in Leidenfrost Droplet Experiments

Suzuki cross-coupling is a widely performed reaction, typically using metal catalysts under heated conditions. Acceleration of the Suzuki cross-coupling reaction has been previously explored in microdroplets using desorption electrospray ionization mass spectrometry (DESI-MS). Building upon previous work, presented here is the use of a high-throughput DESI-MS screening system to identify optimal reaction conditions. Multiple reagents, bases, and stoichiometries were screened using the automated system at rates that approach 10,000 reaction mixture systems per hour. The DESI-MS system utilizes reaction acceleration in microdroplets to allow rapid screening. The results of screening of an array of reaction mixtures using this technique are presented as product ion images via standard MS imaging software, facilitating quick readout. Instructive comparisons are provided with another method of generating droplets for reaction acceleration—the Leidenfrost technique. Acceleration factors greater than 200 were measured for brominated substrates, paralleling the DESI-MS results. Acceleration factors dropped to near unity with highly substituted pyridines, attributable to a steric effect. The reaction proceeded in the absence of a base in Leidenfrost droplets although no product formation was seen without base in the bulk or in the DESI-MS screening experiments. These differences between Leidenfrost chemistry and the bulk and in droplets formed in high-throughput DESI are tentatively attributed to extremes of pH associated with the surfaces of Leidenfrost droplets. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Jumping-Droplet-Enhanced Condensation on Scalable Superhydrophobic Nanostructured Surfaces

When droplets coalesce on a superhydrophobic nanostructured surface, the resulting droplet can jump from the surface due to the release of excess surface energy. If designed properly, these superhydrophobic nanostructured surfaces can not only allow for easy droplet removal at micrometric length scales during condensation but also promise to enhance heat transfer performance. However, the rationale for the design of an ideal nanostructured surface as well as heat transfer experiments demonstrating the advantage of this jumping behavior are lacking. Here, we show that silanized copper oxide surfaces created via a simple fabrication method can achieve highly efficient jumping-droplet condensation heat transfer. We experimentally demonstrated a 25% higher overall heat flux and 30% higher condensation heat transfer coefficient compared to state-of-the-art hydrophobic condensing surfaces at low supersaturations (<1.12). This work not only shows significant condensation heat transfer enhancement but also promises a low cost and scalable approach to increase efficiency for applications such as atmospheric water harvesting and dehumidification. Furthermore, the results offer insights and an avenue to achieve high flux superhydrophobic condensation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Theoretical and Experimental Investigations on Droplet Evaporation and Droplet Ignition at High Pressures

The evaporation of fuel droplets under high ambient pressure and temperature in normal gravity and microgravity has been investigated experimentally. For subcritical ambient conditions, droplet evaporation after a heat-up period follows the d(exp 2)-law. For all data the evaporation constant increases as the ambient temperature increases. At identical ambient conditions the evaporation constant under microgravity is smaller compared to normal gravity. This effect can first be observed at 1 bar and increases with ambient pressure. Preliminary experiments on ignition delay for self-igniting fuel droplets have been performed. Above a 1 s delay time, at identical ambient conditions, significant differences in the results of the normal and microgravity data are observed. Self-ignition occurs within different temperature ranges due to the influence of gravity. The time dependent behavior of the droplet is examined theoretically. In the calculations two different approaches for the gas phase are applied. In the first approach the conditions at the interface are given using a quasi steady theory approximation. The second approach uses a set of time dependent governing equations for the gas phase which are then evaluated. In comparison, the second model shows a better agreement with the drop tower experiments. In both cases a time dependent gasification rate is observed.

Ristau, R.↗

Global Distribution of Cloud Droplet Number Concentration, Autoconversion Rate, and Aerosol Indirect Effect Under Diabatic Droplet Activation

This study presents a global assessment of the sensitivity of droplet number to diabatic activation (i.e., including effects from entrainment of dry air) and its first-order tendency on indirect forcing and autoconversion. Simulations were carried out with the NASA Global Modeling Initiative (GMI) atmospheric and transport model using climatological metereorological fields derived from the former NASA Data Assimilation Office (DAO), the NASA Finite volume GCM (FVGCM) and the Goddard Institute for Space Studies version II (GISS) GCM. Cloud droplet number concentration (CDNC) is calculated using a physically based prognostic parameterization that explicitly includes entrainment effects on droplet formation. Diabatic activation results in lower CDNC, compared to adiabatic treatment of the process. The largest decrease in CDNC (by up to 75 percent) was found in the tropics and in zones of moderate CCN concentration. This leads to a global mean effective radius increase between 0.2-0.5 micrometers (up to 3.5 micrometers over the tropics), a global mean autoconversion rate increase by a factor of 1.1 to 1.7 (up to a factor of 4 in the tropics), and a 0.2-0.4 W m(exp -2) decrease in indirect forcing. The spatial patterns of entrainment effects on droplet activation tend to reduce biases in effective radius (particularly in the tropics) when compared to satellite retrievals. Considering the diabatic nature of ambient clouds, entrainment effects on CDNC need to be considered in GCM studies of the aerosol indirect effect.

Barahona, Donifan↗

Three Stage Cool Flame Droplet Burning Behavior of n-Alkane Droplets at Elevated Pressure Conditions: Hot, Warm and Cool Flame

Transient, isolated n-alkane droplet combustion is simulated at elevated pressure for helium-diluent substituted-air mixtures. We report the presence of unique quasi-steady, three-stage burning behavior of large sphero-symmetric n-alkane droplets at these elevated pressures and helium substituted ambient fractions. Upon initiation of reaction, hot-flame diffusive burning of large droplets is initiated that radiatively extinguishes to establish cool flame burning conditions in nitrogen/oxygen “air” at atmospheric and elevated pressures. However, at elevated pressure and moderate helium substitution for nitrogen ( X He > 20%), the initiated cool flame burning proceeds through two distinct, quasi-steady-state, cool flame burning conditions. The classical “Hot flame ” ( ∼1500 K) radiatively extinguishes into a “Warm flame ” burning mode at a moderate maximum reaction zone temperature ( ∼ 970 K), followed by a transition to a lower temperature ( ∼765 K), quasi-steady “Cool flame ” burning condition. The reaction zone (“flame”) temperatures are associated with distinctly different yields in intermediate reaction products within the reaction zones and surrounding near-field, and the flame-standoff ratios characterizing each burning mode progressively decrease. The presence of all three stages first appears with helium substitution near 20%, and the duration of each stage is observed to be strongly dependent on helium substitutions level between 20–60%. For helium substitution greater than 60%, the hot flame extinction is followed by only the lower temperature cool flame burning mode. In addition to the strong coupling between the diffusive loss of both energy and species and the slowly evolving degenerate branching in the low and negative temperature coefficient (NTC) kinetic regimes, the competition between the low-temperature chain branching and intermediate-temperature chain termination reactions control the “Warm” and “Cool ” flame quasi-steady conditions and transitioning dynamics.

Droplet Combustion↗

Redistribution of ice nuclei between cloud and rain droplets: Parameterization and application to deep convective clouds: ICE NUCLEI IN RAIN DROPLETS

In model studies of aerosol-dependent immersion freezing in clouds, a common assumption is that each ice nucleating aerosol particle corresponds to exactly one cloud droplet. Conversely, the immersion freezing of larger drops—“rain”—is usually represented by a liquid volume-dependent approach, making the parameterizations of rain freezing independent of specific aerosol types and concentrations. This may lead to inconsistencies when aerosol effects on clouds and precipitation shall be investigated, since raindrops consist of the cloud droplets—and corresponding aerosol particles—that have been involved in drop-drop-collisions. We introduce an extension to a two-moment microphysical scheme in order to account explicitly for particle accumulation in raindrops by tracking the rates of selfcollection, autoconversion, and accretion. This also provides a direct link between ice nuclei and the primary formation of large precipitating ice particles. A new parameterization scheme of drop freezing is presented to consider multiple ice nuclei within one drop and effective drop cooling rates. In our test cases of deep convective clouds, we find that at altitudes which are most relevant for immersion freezing, the majority of potential ice nuclei have been converted from cloud droplets into raindrops. Compared to the standard treatment of freezing in our model, the less efficient mineral dust-based freezing results in higher rainwater contents in the convective core, affecting both rain and hail precipitation. The aerosol-dependent treatment of rain freezing can reverse the signs of simulated precipitation sensitivities to ice nuclei perturbations.

54 ENVIRONMENTAL SCIENCES↗

Surfactants and cloud droplet activation: A systematic extension of Köhler theory based on analysis of droplet stability

The activation of aerosol particles to form cloud droplets, a necessary first step in cloud formation, controls much of the impact that aerosols have on clouds and climate. Recently, there has been a surge of interest in extending the Köhler theory of cloud droplet activation to include surface active (typically organic) as well as water-soluble (typically inorganic) aerosol components, but a systematic framework for doing this has yet to be developed. Here, we apply a droplet stability analysis to this end. Ideal and Szyszkowski–Langmuir surfactant models are analyzed to demonstrate the new approach, but the underlying theoretical framework is fundamental and model free. A key finding is that superficial densities at the cloud activation threshold (Köhler maximum) are significantly sub-monolayer, with fractional coverage ranging from 69% to 85% for the organic compounds and mixtures studied. The result, significant for model inventories of cloud condensation nuclei, is a weakening of the surfactant effect relative to expectations based on bulk sample measurements. Analytical results are obtained for the loci of Köhler maxima and applied to aerosol mixtures containing an arbitrary number of water-soluble and surfactant components.

54 ENVIRONMENTAL SCIENCES↗

Research study of droplet sizing technology leading to the development of an advanced droplet sizing system

An instrument to measure the size and velocity of droplets was developed. The instrument uses one of two techniques, as appropriate. In the first technique two small laser beams of one color identify the center of a larger laser beam of a different color. This defines a region of almost uniform intensity where the light scattered by the individual droplets can be related to their size. The first technique uses the visibility of a Doppler burst and validates it against the peak intensity of the signal's pedestal. Results are presented for monodisperse, bimodal, trimodal, and polydisperse sprays produced by the Berglund-Liu droplet generator and a pressure nozzle. Size distributions of a given spray obtained using three different size ranges show excellent self-consistency in the overlapping region. Measurements of sprays of known characteristics exhibit errors in the order of 10%. The principles of operation and design criteria of the instrument are discussed in great detail.

Hess, C. F.↗

The design and performance of a multi-stream droplet generator for the liquid droplet radiator

Results are presented for the performance capabilities of a multistream droplet generator suitable for use in a spacecraft liquid droplet radiator heat-rejection system. The nozzle-motion mode of stream perturbation initiation was tested with a single droplet stream and found to produce data similar to those generated with the resonant cavity mode of perturbation. Tests then proceeded to a 26-orifice array; the streams of the array responded to the perturbation satisfactorily, forming uniformly separated drops.

Orme, Melissa↗