False Data Injection Attack Detection Methods for Battery Stacks with Input Noise
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.
The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.
In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.
Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.
Security related questions for Cyber Physical Systems (CPS) have attracted much research attention in searching for novel methods for attack-resilient control and/or estimation. Specifically, false data injection attacks (FDIAs) have been shown to be capable of bypassing bad data detection (BDD), while arbitrarily compromising the integrity of state estimators and robust controller even with very sparse measurements corruption. Moreover, based on the inherent sparsity of pragmatic attack signals, ℓ1 -minimization scheme has been used extensively to improve the design of attack-resilient estimators. For this, the theoretical maximum for the percentage of compromised nodes that can be accommodated has been shown to be 50%. In order to guarantee correct state recoveries for larger percentage of attacked nodes, researchers have begun to incorporate prior information into the underlying resilient observer design framework. For the most pragmatic cases, this prior information is often obtained through some data-driven machine learning process. Existing results have shown strong positive correlation between the tolerated attack percentages and the precision of the prior information. In this paper, we present a pruning method to improve the precision of the prior information, given corresponding stochastic uncertainty characteristics of the underlying machine learning model. Then a weighted ℓ1 -minimization is proposed based on the pruned prior. The theoretical and simulation results show that the pruning method significantly improves the observer performance for much larger attack percentages, even when moderately accurate machine learning model used.
The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.
Network constrained grid edge energy management system (EMS) provides economic solution for active and reactive power dispatch of distributed energy resources (DERs) at the grid edge level. Grid edge EMS ensures secure interconnection of a circuit segment to the distribution system by maintaining grid code requirements (e.g. IEEE 1547–2018). Grid edge EMS is dependent on communication to receive load measurement, which brings a risk of unobservable false data injection attacks (FDIAs). To mitigate the risk, this paper proposes a framework to enhance resilient operation of grid edge EMS by detecting the unobservable FDIAs on loads and replacing them with forecasted values. In this work, a two-step detection algorithm is proposed. In first step, conventional residual based algorithm is deployed. Autoencoder (AE) based data driven mechanism is included in second step to detect the presence of unobservable FDIAs. After ensuring the presence of FDIA, its specific location is detected by checking the maximum residue values till the predefined threshold value is reached. Detected false data injected loads are then replaced with forecasted load values following long-short term memory (LSTM) based forecast to ensure resilient performance of grid edge EMS in the presence of attacks. This proposed security enhancement framework for grid edge EMS is evaluated in IEEE 13 bus system with three integrated DERs. Numerical simulation shows the validation of the proposed framework by reducing voltage violation in real operation of grid edge EMS.
Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.
One major tool of Energy Management Systems for monitoring the status of the power grid is State Estimation. Since the results of state estimation are used within the energy management system, the security of the state estimation process is most important. The focus research in this area is on detecting False Data Injection attacks on measurements. While this is important, State Estimation also rely on database that are used to describe the relationship between measurements and systems' states. This paper presents a two-stage programming framework to detect and correct attacks in the parameters of the measurement model used by the state estimation process in the Energy Management System. In the first stage, an estimate of the line parameters ratios are obtained. In the second stage, the estimated ratios from stage I are used in a Bi-Level model for obtaining a final estimate of the measurements' model parameters. Hence, the presented framework does not only unify the detection and correction in a single optimization run, but also provide a monitoring scheme for the SE database that is typically considered static. In addition, in the two stages, linear programming framework is preserved. For validation, the IEEE 118 bus system is used for implementation. The results of this paper illustrate the effectiveness of the proposed model for detecting attacks in the database used in the state estimation process.
Smart devices are essential to ensure the stability of the power grid and resilience to intermittent energy production. However, smart devices can also be the target of cyber adversaries that may exploit false data injection attacks (FDIAs) to induce unstable grid conditions. A practical consideration of FDIA mitigation approaches is addressed here: given a finite available budget, for which smart device should cyber-threat mitigation be deployed first? In this work, this question is answered by identifying the so-called most-sensitive devices, i.e., the devices that, if compromised, can let an adversary induce the most serious grid instabilities. The method proposed utilizes an adversarial reinforcement learning (RL) framework to identify the k-mostsensitive smart devices (here, smart inverters). The adversarial agent can tamper with the compromised inverters' active and reactive operating power setup points, with the goal of maximizing voltage deviations. Numerical results show that the proposed RL method finds the optimal attack scenarios for 1-point failure and the near-optimal solution for the 2-point case. Additionally, the proposed RL method achieves an 8.8 speed-up ratio in running time compared to the brute force method for the 2-point case.
Supervisory Control and Data Acquisition (SCADA) systems are utilized extensively in critical power grid infrastructures. Modern SCADA systems have been proven to be susceptible to cyber-security attacks and require improved security primitives in order to prevent unwanted influence from an adversarial party. One section of weakness in the SCADA system is the integrity of field level sensors providing essential data for control decisions at a master station. In this paper we propose a lightweight hardware scheme providing inferred authentication for SCADA sensors by combining an analog to digital converter and a permutation generator as a single integrated circuit. Through this method we encode critical sensor data at the time of sensing, so that unencoded data is never stored in memory, increasing the difficulty of software attacks. We show through experimentation how our design stops both software and hardware false data injection attacks occurring at the field level of SCADA systems.
The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.
GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.
The cybersecurity threats of power system gradually grow due to the increased sophisticated interactions between Information Technology (IT) and Operational Technology (OT) networks. False data injection attack (FDIA) that aims to compromise the Supervisory Control and Data Acquisition (SCADA) measurement and disturb the system operation is one of such cyber threats. Such attacks can potentially lead to significant operational issues at the control centers and substations, and hence, result in severe physical consequences. To avoid catastrophic failure across the power grid resulting from these attacks, it is essential to arm the OT network with real-time vulnerability assessment tools. To this end, this paper outlines various drawbacks of the Purdue architecture model to defend against cyberattacks in the OT network. Furthermore, a novel ensemble-based state prediction model is proposed to detect cybersecurity anomalies in SCADA assisted OT networks. The proposed model uses control center level generation and load forecasts, scheduled, and forced outages, power flow solutions, and the substation level historical data. The hypothesis of the proposed scheme relies on the fact that additional control center and substation data can hardly be accessed and compromised by attackers. One of the vital features of the proposed scheme is an hour-ahead prediction of the operational feasibility of the SCADA measurement range at the control center and substation in real time helps in detecting anomalies in measurements across both substation and the control center.
In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.