Search NASA⌕ Search

SEARCH · Search NASA

Results for “Databank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cox Proportional Hazards Models for Modeling the Time to Onset of Decompression Sickness in Hypobaric Environments

In this paper we fit Cox proportional hazards models to a subset of data from the Hypobaric Decompression Sickness Databank. The data bank contains records on the time to decompression sickness (DCS) and venous gas emboli (VGE) for over 130,000 person-exposures to high altitude in chamber tests. The subset we use contains 1,321 records, with 87% censoring, and has the most recent experimental tests on DCS made available from Johnson Space Center. We build on previous analyses of this data set by considering more expanded models and more detailed model assessments specific to the Cox model. Our model - which is stratified on the quartiles of the final ambient pressure at altitude - includes the final ambient pressure at altitude as a nonlinear continuous predictor, the computed tissue partial pressure of nitrogen at altitude, and whether exercise was done at altitude. We conduct various assessments of our model, many of which are recently developed in the statistical literature, and conclude where the model needs improvement. We consider the addition of frailties to the stratified Cox model, but found that no significant gain was attained above a model that does not include frailties. Finally, we validate some of the models that we fit.

Thompson, Laura A.↗

A Generalized Multi-Phase Framework for Modeling Cavitation in Cryogenic Fluids

A generalized multi-phase formulation for cavitation in fluids operating at temperatures elevated relative to their critical temperatures is presented. The thermal effects and the accompanying property variations due to phase change are modeled rigorously. Thermal equilibrium is assumed and fluid thermodynamic properties are specified along the saturation line using the NIST-12 databank. Fundamental changes in the physical characteristics of the cavity when thermal effects become pronounced are identified; the cavity becomes more porous, the interface less distinct, and has increased entrainment when temperature variations are present. Quantitative estimates of temperature and pressure depressions in both liquid nitrogen and liquid hydrogen were computed and compared with experimental data of Hord for hydrofoils. Excellent estimates of the leading edge temperature and pressure depression were obtained while the comparisons in the cavity closure region were reasonable. Liquid nitrogen cavities were consistently found to be in thermal equilibrium while liquid hydrogen cavities exhibited small, but distinct, non-equilibrium effects.

Dorney, Dan↗

Relationship of the time course of venous gas bubbles to altitude decompression illness

The correlation is low between the occurrence of gas bubbles in the pulmonary artery, called venous gas emboli (VGE), and subsequent decompression illness (DCI). The correlation improves when a "grade" of VGE is considered; a zero to four categorical classification based on the intensity and duration of the VGE signal from a Doppler bubble detector. Additional insight about DCI might come from an analysis of the time course of the occurrence of VGE. Using the NASA Hypobaric Decompression Sickness Databank, we compared the time course of the VGE outcome between 322 subjects who exercised and 133 Doppler technicians who did not exercise to evaluate the role of physical activity on the VGE outcome and incidence of DCI. We also compared 61 subjects with VGE and DCI with 110 subjects with VGE but without DCI to identify unique characteristics about the time course of the VGE outcome to try to discriminate between DCI and no-DCI cases. The VGE outcome as a function of time showed a characteristic short lag, rapid response, and gradual recovery phase that was related to physical activity at altitude and the presence or absence of DCI. The average time for DCI symptoms in a limb occurred just before the time of the highest fraction of VGE in the pulmonary artery. It is likely, but not certain, that an individual will report a DCI symptom if VGE are detected early in the altitude exposure, the intensity or grade of VGE rapidly increases from a limb region, and the intensity or grade of VGE remains high.

NASA Discipline Environmental Health↗

Miniature Heat Transport System for Spacecraft Thermal Control

Loop heat pipes (LHP) are efficient devices for heat transfer and use the basic principle of a closed evaporation-condensation cycle. The advantage of using a loop heat pipe over other conventional methods is that large quantities of heat can be transported through a small cross-sectional area over a considerable distance with no additional power input to the system. By using LHPs, it seems possible to meet the growing demand for high-power cooling devices. Although they are somewhat similar to conventional heat pipes, LHPs have a whole set of unique properties, such as low pressure drops and flexible lines between condenser and evaporator, that make them rather promising. LHPs are capable of providing a means of transporting heat over long distances with no input power other than the heat being transported because of the specially designed evaporator and the separation of liquid and vapor lines. For LHP design and fabrication, preliminary analysis on the basis of dimensionless criteria is necessary because of certain complicated phenomena that take place in the heat pipe. Modeling the performance of the LHP and miniaturizing its size are tasks and objectives of current research. In the course of h s work, the LHP and its components, including the evaporator (the most critical and complex part of the LHP), were modeled with the corresponding dimensionless groups also being investigated. Next, analysis of heat and mass transfer processes in the LHP, selection of the most weighted criteria from known dimensionless groups (thermal-fluid sciences), heat transfer rate limits, (heat pipe theory), and experimental ratios which are unique to a given heat pipe class are discussed. In the third part of the report, two-phase flow heat and mass transfer performances inside the LHP condenser are analyzed and calculated for Earth-normal gravity and microgravity conditions. On the basis of recent models and experimental databanks, an analysis for condensing two-phase flow regimes, pressure gradients, and local heat transfer coefficients using ammonia, propylene, and R134, are carried out.

Ochterbeck, Jay M.↗

Particle and Trace Gas Emissions Indices Measured During the 2021 Boeing ecoDemonstrator Emissions Ground Test

We present particle and trace gas emissions indices sampled on the ground at 30 meters behind the CFM LEAP-1B engines of the 2021 Boeing ecoDemonstrator, an Alaska Airlines 737-9 aircraft. Testing was carried out at Boeing Field in Seattle, WA, USA in Fall of 2021. Four different fuels were investigated including a 100% sustainable aviation fuel (SAF), a petroleum-based Jet A fuel, and two SAF blends. Total and non-volatile particle number concentrations were measured with a pair of condensation particle counters with one operating behind a custom-built thermal denuder heated to 350 degrees Celsius. Similarly, total and non-volatile particle number size distributions were measured with a pair of Scanning Mobility Particle Sizers (SMPSs). Non-volatile particle mass was estimated from particle light absorption techniques using an assumed mass absorption coefficient, while particle chemical speciation was measured by an Soot Particle Aerosol Mass Spectrometer (SP-AMS). A detailed list of instruments is given on the project website [1]. Overall, the results are consistent with expectations based on ICAO Emissions Databank certification data for the LEAP-1B with a stark reduction in non-volatile particle number and mass observed for the higher thrust conditions when the combustor was staged. The production of volatile particles under these conditions as well as experimental considerations related to background subtraction methods will be discussed. References: [1] Boeing ecoDemonstrator Science and Engineering Team (2022). 2021 Boeing ecoDemonstrator Emissions Ground Test Dataset

Richard H Moore↗

Transient Aircraft Soot Emissions Indicate That Steady-State Measurements Likely Underestimate Real-World, Take-Off Emissions: Time-Varying Aircraft Take-Off Emissions Indices Measured at Los Angeles International Airport

Aircraft engine emissions are unique among mobile pollution sources in that their impacts affect the local air quality near airports as well as upper tropospheric composition and climate over regional-to-hemispheric scales. Furthermore, air travel and its resulting emissions are expected to rebound from the recent COVID-related lows to increase dramatically over the next several decades. Given the multi-decade service lifetime of many commercial aircraft, it is critically important to quantitatively understand the real-world emissions coming from these engines in order to inform environmental assessment and modelling activities. Here, we present a detailed analysis of aircraft emissions during take-off operations at Los Angeles International Airport. The data were collected as part of the NASA Alternative Fuel Effects on Contrails and Cruise Emissions (ACCESS) project in May 2014, and the dataset is publicly available as described by Moore et al. [1]. In particular, we focus on the time-varying nature of the plume concentrations where clear differences in particle size and non-volatile particle fraction are observed during the early portion of the take-off plume relative to the later portion of the plume. We compare the transient emissions indices measured here to engine certification values in the International Civil Aviation Organization (ICAO) Emissions Databank, which suggests that steady-state measurements may underestimate the real-world, non-volatile particle emissions. The implications of this finding for modelling aircraft particle emissions will be discussed.

Richard H. Moore↗

Particle and Trace Gas Emissions Indices Measured During the 2021 Boeing ecoDemonstrator Emissions Ground Test

We present particle and trace gas emissions indices sampled on the ground at 30 meters behind the CFM LEAP-1B engines of the Boeing ecoDemonstrator 737-9 aircraft. Testing was carried out at Boeing Field in Seattle, WA, USA in Fall of 2021. Four different fuels were investigated including a 100% sustainable aviation fuel (SAF), a petroleum-based Jet A fuel, and two SAF blends. Total and non-volatile particle number concentrations were measured with a pair of condensation particle counters with one operating behind a custom-built thermal denuder heated to 350 degrees Celsius. Similarly, total and non-volatile particle number size distributions were measured with a pair of Scanning Mobility Particle Sizers (SMPSs). Non-volatile particle mass was estimated from particle light absorption techniques using an assumed mass absorption coefficient, while particle chemical speciation was measured by an Soot Particle Aerosol Mass Spectrometer (SP-AMS). A detailed list of instruments is given on the project website [1]. Overall, the results are consistent with expectations based on ICAO Emissions Databank certification data for the LEAP-1B with a stark reduction in non-volatile particle number and mass observed for the higher thrust conditions when the combustor was staged. The production of volatile particles under these conditions as well as experimental considerations related to background subtraction methods will be discussed.

Benjamin A. Nault↗

Theoretical Predictions of the thermodynamic Properties of Solid Sorbents Capture CO2 Applications

We are establishing a theoretical procedure to identify most potential candidates of CO{sub 2} solid sorbents from a large solid material databank to meet the DOE programmatic goal for energy conversion; and to explore the optimal working conditions for the promising CO{sub 2} solid sorbents, especially from room to warm T ranges with optimal energy usage, used for both pre- and post-combustion capture technologies.

36 MATERIALS SCIENCE↗

Theoretical Screening of Mixed Solid Sorbents for CO{sub 2} Capture

We are establishing a theoretical procedure to identify most potential candidates of CO{sub 2} solid sorbents from a large solid material databank to meet the DOE programmatic goal for energy conversion; A further objective is to explore the optimal working conditions for the promised CO{sub 2} solid sorbents, especially from room to warm T ranges with optimal energy usage, used for both pre- and post-combustion capture technologies.

36 MATERIALS SCIENCE↗

Theoretical Screening of Solid Sorbents for CO{sub 2} Capture Applications

The work reported in this presentation was establishing a theoretical procedure to identify most potential candidates of CO{sub 2} solid sorbents from a large solid material databank; and to explore the optimal working conditions for the promised CO{sub 2} solid sorbents and provide guidelines to the experimentalists. Our methodology can predict thermodynamic properties of solid materials and their CO{sub 2} capture reactions. Single solid may not satisfy the industrial operating conditions as CO{sub 2} sorbent, however, by mixing two or more solids, the new formed solid may satisfy the industrial needs. By exploring series of lithium silicates with different Li{sub 2}O/SiO{sub 2} ratio, we found that with decreasing Li{sub 2}O/SiO{sub 2} ratio the corresponding silicate has a lower turnover temperature and vice versa. Compared to pure MgO, the Na{sub 2}CO{sub 3}, K{sub 2}CO{sub 3} and CaCO{sub 3} promoted MgO sorbent has a higher turnover T. These results provide guidelines to synthesize sorbent materials by mixing different solids with different ratio.

36 MATERIALS SCIENCE↗

Theoretical Screening of Solid Sorbents for CO{sub 2} Capture Applications

The work reported in this presentation was establishing a theoretical procedure to identify most potential candidates of CO{sub 2} solid sorbents from a large solid material databank; and to explore the optimal working conditions for the promised CO{sub 2} solid sorbents and provide guidelines to the experimentalists. Our methodology can predict thermodynamic properties of solid materials and their CO{sub 2} capture reactions. Single solid may not satisfy the industrial operating conditions as CO{sub 2} sorbent, however, by mixing two or more solids, the new formed solid may satisfy the industrial needs. By exploring series of lithium silicates with different Li{sub 2}O/SiO{sub 2} ratio, we found that with decreasing Li{sub 2}O/SiO{sub 2} ratio the corresponding silicate has a lower turnover temperature and vice versa. Compared to pure MgO, the Na{sub 2}CO{sub 3}, K{sub 2}CO{sub 3} and CaCO{sub 3} promoted MgO sorbent has a higher turnover T. These results provide guidelines to synthesize sorbent materials by mixing different solids with different ratio.

36 MATERIALS SCIENCE↗

Automated diagnostic kiosk for diagnosing diseases

An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

60 APPLIED LIFE SCIENCES↗

Mixed and Doped Solid Sorbents for CO 2 Capture Applications

The objectives of this presentation are to capture CO2 we need materials with optimal performance and low costs; establish a theoretical procedure to identify most potential candidates of CO 2 solid sorbents from a large solid material databank; computational synthesis new materials to fit industrial needs; and explore the optimal working conditions for the promised CO 2 solid sorbents, especially from room to warm T ranges with optimal energy usage.

01 COAL, LIGNITE, AND PEAT↗

Progress on the development of new correlations under the framework of the IAEA Coordinated Research Programme on heat transfer in SCWR's

This paper begins with an introduction designed to provide researchers who are new to field of heat transfer to fluids at supercritical pressure with a brief picture of early developments, and to set the scene for the review of work on the development of new correlations for such fluids under the framework of the IAEA CRP. These are needed because of the active consideration now being given to water-cooled nuclear reactors operating at pressures above the critical value. Work on the development of a trans-critical look-up table aimed at covering the region near the critical point is outlined. A very large heat transfer databank has been compiled and subjected to a thorough screening process. It covers a wide range of conditions and has been used for the assessment of the performance of a number of empirical equations. A detailed error analysis was carried out for the most promising ones and an examination of parametric trends was made. A new correlation is described which has been specifically designed to combine simplicity of structure, explicit connection with physically-based phenomena whilst being able to cover both normal and deteriorated heat transfer conditions. It avoids direct dependence of heat transfer coefficient on wall temperature. The performance of this correlation was evaluated using the data set of Herkenrath et al for water at supercritical pressure. Results from a recent experimental study of heat transfer to carbon dioxide at supercritical pressure under conditions of mixed convection have been used to develop a set of equations to describe the general behaviour observed. Comparisons are made between the performance of a number of equations and the data from the carbon dioxide experiments and also some for water. Finally, the development is outlined of physically-based, semi-empirical models aimed at extending an empirical equation for variable property forced convection heat transfer to fluids at supercritical pressure to account for influences of buoyancy and flow acceleration. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Environmental Radiation Monitoring at the Areas of the Former Military Technical Bases at the Russian Far East - 12445

After termination of operation at the serviced facilities of the nuclear fleet of the former Soviet Union, the Military Technical Base in Sysoeva Bay has been reorganized to the site for SNF and RW temporary storage (STS). The main activities of STS are receipt, storage and transmission to radioactive waste reprocessing. Establishment of the RW management regional centre in the Far-Eastern region at the STS in Sysoeva Bay implies intensification of SNF and RW management in this region that can result in increasing ecological load to the adjacent areas and settlements. Regulatory supervision of the radiation safety at the areas of the Former Military Technical Bases at the Russian Far East is one of the regulatory functions of the Federal Medical Biological Agency (FMBA of Russia). To regulate SNF an RW management and provide the effective response to changing radiation situation, the environmental radiation monitoring system is arranged. For this purpose, wide range of environmental media examinations at the Sysoeva Bay STS was performed by Burnasyan Federal Medical Biophysical Centre - a technical support organization of FMBA of Russia in collaboration with the Federal State Geological Enterprise 'Hydrospecgeology' (Federal Agency for Entrails). Regulation during the RW and SNF management is continuous process, which the FMBA of Russia implements in close cooperation with other Russian responsible authorities - the State Atomic Energy Corporation 'Rosatom' and Federal Agency for Entrails. The Environmental radiation monitoring findings served as a basis for the associated databank arrangement. The radio ecological monitoring system was arranged at the facilities under inspection for the purpose of the dynamic control of the radiation situation. It presupposes regular radiometry inspections in-situ, their analysis and assessment of the radiation situation forecast in the course of the STS remediation main stages. Some new data on the radiation situation at the facilities will appear in future and the prognostic assessment will become more precise. The mentioned natural, practical and theoretical works is a base for the development of the set of regulatory documents to assure radiation protection and safety of workers, public and environment, as well as development of documents to regulate SNF and RW management at the STS facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The container database? life-cycle management of container inventories at the Hanford site - 15131

Since 2011 the Department of Energy (DOE) Richland Operations Office (DOE-RL) and their contractor CH2M HILL Plateau Remediation Company (CH2M HILL) have worked together to develop a database that provides life-cycle management and control of all CH2M HILL-managed Department of Transportation (DOT) Type A and Industrial Packaging (IP) container assets at the Hanford Site. This powerful tool provides CH2M HILL with the capability to centrally manage container procurement specifications; maintenance requirements; certificates of conformance; certification and test reports; as-built drawings; and information on container status, location, and ownership; and any special characteristics of container assets. The database was originally developed to provide ready access to Type A and IP container supplier and manufacturer Certificates of Conformance (CoCs) and related certification documentation to support onsite shipments in compliance with the Hanford Site Wide Transportation Safety Document (TSD), DOE/RL-2001-0036, as well as regulatory or other requirements. The information is accessed through active links to these documents within the database itself. The database has grown to include links to external supplementary information to support onsite shipments, such as links to authorized tie downs for each package type, approved packaging and transportation commodities, and approved shipping authorizations, and packaging management procedures and checklists. The database is a living databank that is easily tailored to meet user- and site-specific needs as they are identified. It is currently being expanded to include the inventories of all Hanford contractors, as well as other packaging assets, such as specialty drums and packaging commodities. Each upgrade brings efficiencies and cost savings, not only in container inventory management, but also in the areas of work control, waste packaging, waste transportation, and regulatory compliance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of Void Fraction Distribution in Steam-Water Two-Phase Flow in a 44 Bundle at 2 MPa

To contribute to the clarification of the Fukushima Daiichi Accident, JAEA is working on getting instantaneous void fraction distribution data in steam-water two-phase flow in rod bundle geometry under high pressure, high temperature condition, with using Wire Mesh Sensor (WMS) developed at JAEA for high pressure, high temperature condition (Up to 2.8 MPa, 230 deg. C), focusing on the low flow rate condition after the reactor scram. The data is expected to be used in the validation of the detailed two-phase flow codes TPFIT and ACE3D developed at JAEA. The time and space averaged void fraction data is also expected being used in the validation of the drift-flux models implemented in the two fluids codes, such as TRACE code. We are still in the middle of the data analyses and here we only report a part of the results. For the present bundle rod geometry, the void fraction shows easily gathered at the center area surrounded by 4 rods and the void fraction in the sub - channels between two adjacent rods are low. Under the same steam vapor flow rate condition, void faction increase with the decrease of the water flow rate. Under the same water flow rate, the void fraction increases with the increase of the steam vapor flow rate. In recent future, we will perform more experiments under further low water flow rate condition, including stagnation condition, to confirm this changing tendency. In the present experimental range, no effect of pressure on void fraction was observed. A 3-layer WMS, with a vertical distance between the adjacent layers of 1.3 mm, was used to measure the local instantaneous void fraction in this research. By using the correlation coefficient method, we can determine the time delay between the bubble detections from the upper and the lower layer sensors. Then the speed of the bubble, and its length, can be calculated. We are working on the establishment of the databank for the slug-churn bubbles information. (authors)

42 ENGINEERING↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗