Search NASA⌕ Search

SEARCH · Search NASA

Results for “Density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Gas temperature and density measurements based on spectrally resolved Rayleigh-Brillouin scattering

The use of molecular Rayleigh scattering for measurements of gas density and temperature is evaluated. The technique used is based on the measurement of the spectrum of the scattered light, where both temperature and density are determined from the spectral shape. Planar imaging of Rayleigh scattering from air using a laser light sheet is evaluated for ambient conditions. The Cramer-Rao lower bounds for the shot-noise limited density and temperature measurement uncertainties are calculated for an ideal optical spectrum analyzer and for a planar mirror Fabry-Perot interferometer used in a static, imaging mode. With this technique, a single image of the Rayleigh scattered light can be analyzed to obtain density (or pressure) and temperature. Experimental results are presented for planar measurements taken in a heated air stream.

Seasholtz, Richard G.↗

Multiple Point Dynamic Gas Density Measurements Using Molecular Rayleigh Scattering

A nonintrusive technique for measuring dynamic gas density properties is described. Molecular Rayleigh scattering is used to measure the time-history of gas density simultaneously at eight spatial locations at a 50 kHz sampling rate. The data are analyzed using the Welch method of modified periodograms to reduce measurement uncertainty. Cross-correlations, power spectral density functions, cross-spectral density functions, and coherence functions may be obtained from the data. The technique is demonstrated using low speed co-flowing jets with a heated inner jet.

Seasholtz, Richard↗

Density measurement in compressible flows using off-resonant laser-induced fluoresence

Measurement of molecular number density in compressible flows using laser-induced fluorescence is complicated by collisional quenching of the exicited state. It is shown that by exciting the fluorescence off-resonance the signal becomes proportional to number density and independent of collisional effects. Quantitative measurement of density in an underexpanded jet of nitrogen is demonstrated using off-resonant fluoresence from iodine seed molecules irradiated with the 514.5 nm line of the argon-ion laser.

Mcdaniel, J. C.↗

Acoustic levitation methods for density measurements

The capability of ultrasonic levitators operating in air to perform density measurements has been demonstrated. The remote determination of the density of ordinary liquids as well as low density solid metals can be carried out using levitated samples with size on the order of a few millimeters and at a frequency of 20 kHz. Two basic methods may be used. The first one is derived from a previously known technique developed for acoustic levitation in liquid media, and is based on the static equilibrium position of levitated samples in the earth's gravitational field. The second approach relies on the dynamic interaction between a levitated sample and the acoustic field. The first technique appears more accurate (1 percent uncertainty), but the latter method is directly applicable to a near gravity-free environment such as that found in space.

Trinh, E. H.↗

90-GHz flux-density measurements of variable radio sources

Results are presented for measurements of the flux densities of 10 variable extragalactic sources at 85.2 or 90 GHz, which were made over a period of almost seven years with the NRAO 36-ft millimeter-wave antenna. The primary flux-density calibration standards used include Jupiter, Saturn, Mars, and the small-diameter Galactic source DR 21. Measured flux densities are given as a function of time (in years) for the sources 3C 84, NRAO 150, 3C 120, OJ 287, 4C 39.25, 3C 273, 3C 279, 3C 345, BL Lac, and 3C 454.3. No statistically meaningful flux-density changes during an observing interval (1 to 3 days) are detected for any source, and a high degree of correlation between flux-density variations at 85.2 or 90 GHz and those observed at lower frequencies is found in all 10 sources. Some variations observed at different frequencies in several individual sources are briefly discussed.

Hobbs, R. W.↗

Recognition of crops and soils by spot density measurements of imagery

Computerized techniques and methods were used to conduct preliminary soil and crop identification experiments. The soil identification experiment was conducted by making densitometer measurements on Ektachrome infrared film exposed at 14,000 feet. The density measurements were analyzed by plotting sample probability density functions, two-dimensional scatter plots, and the use of K-class I to determine the complete set of classification results for one, two, three and four features. Due to the presence of nineteen classes, crop identification experiments were more difficult to formulate. Classes of corn, fallow, harvested wheat, roadways, trees and water were classified 75 percent correct.

Nelson, G. D.↗

Rayleigh Scattering Density Measurements from Ultrafast Lasers in High-Pressure, Cryogenic Wind Tunnels

The Rayleigh scattering signal from femtosecond laser pulses is examined for its utility at making instantaneous density measurements in the NASA Langley 0.3-m Transonic Cryogenic Tunnel. An electron-multiplying CCD camera is used to visualize Rayleigh scattering signal taken concurrently with velocity measurements utilizing the femtosecond laser tagging velocimetry technique (FLEET). The results indicate a strong potential for making instantaneous measurements. Viable single-shot images are obtained over the full operational envelope of the facility, and shot-to-shot variations are found to be on average 6 percent (at 95 percent confidence level) and tend to decrease as the facility density is increased. The Rayleigh scattering signals observed before the optical focus exhibit a characteristically linear dependence on the mass-density of the gas, while signals after the focus exhibit a nonlinear (sublinear) density dependence, indicative of stronger absorption at higher densities. The measured Rayleigh scattering signals compare favorably to theoretical assessments made at the tunnel operating conditions.

Burns, Ross A.↗

Raman Temperature and Density Measurements in Supersonic Jets

Prediction of flow-field properties in supersonic jets using computational fluid dynamics (CFD) code predictions has become routine; however, obtaining accurate solutions becomes more challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are significant. Benchmark sets of flow field property data are required in order to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of temperatures and turbulent heat flux is important. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering (SRS) spectroscopy and Background Oriented Schlieren (BOS) have been previously used to acquire measurements of the mean and root mean square (rms) velocities, the mean and rms gas temperatures and density gradients in subsonic jet flows and film cooling flows. In this work, the ability to measure density is added to the list of measurands available using the acquired Raman spectra. The suite of measurement techniques are now applied to supersonic jet flows. The computation of the local gas pressure in the potential core of an over-expanded jet is demonstrated using the Raman measured gas temperature and density. Additionally, a unique density feature in temperature matched, perfectly expanded jet flow shear layers identified using BOS was verified using the Raman measurement technique. These non-intrusive flow measurements are compared against RANS predictions of the supersonic jet flow properties as a means of assessing their prediction accuracy.

Raman Spectroscopy↗