Search NASA⌕ Search

SEARCH · Search NASA

Results for “Desiccant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Super-adsorbing porous thermo-responsive desiccants

Thermo-responsive hydrogel composite (TRHC) desiccants having high adsorption capacities, fast adsorption/desorption rates, and low regeneration temperatures (Treg) compared to traditional desiccants. TRHC desiccants may be synthesized by freeze drying. The porous structures resulting from freeze drying copolymers of thermo-responsive polymers and/or hygroscopic agents may be combined with hygroscopic inorganic salts, resulting in TRHC desiccants having superior performance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The physics of desiccation cracks 1: Ductile fracturing and dependence on relative humidity

Ductile deformation is ubiquitously found in the shrinkage of geomaterials. The existence of ductility requires elastoplastic mechanics when analyzing the structure deformation under external stress. Here, in this work, we explore the physics of ductile fracturing based on the results from desiccation experiments and triaxial tests. By using the digital image correlation (DIC) method to generate the strain maps of samples undergoing desiccation cracking under different relative humidities, we obtain results showing the previously postulated Cnoidal Wave ductile failure patterns propagating under atmospheric condition-controlled crack velocities. We then correlate these observations with rate-dependent plasticity models calibrated through triaxial tests undergoing several unloading–reloading cycles and velocity stepping. This work demonstrates the necessity to consider ductility in soil cracking, indicating that the formation of crack patterns in soil desiccation is a slow and predictable process.

58 GEOSCIENCES↗

Material properties of aqueous potassium acetate solutions for use in liquid desiccant air conditioning

We present thermophysical properties of aqueous potassium acetate solutions relevant to their application as a liquid desiccant in air-conditioning systems. Liquid desiccant air conditioners could provide up to 80% energy savings compared to high-efficiency vapor compression air conditioners. However, the commonly used liquid desiccants, particularly chloride salt solutions, are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Potassium acetate has been identified as a less corrosive alternative, potentially enabling broader material compatibility in LDAC components. In this study we systematically measured and modelled key thermophysical properties of KAc solutions density, vapor pressure, viscosity, specific heat capacity, phase behavior, and diffusion coefficient across a range of concentrations (10 - 70wt%) and temperatures. For instance, KAc exhibits a vapor pressure of 3.1 kPa at 50wt% and 40degrees C, demonstrating dehumidification capability comparable to chloride salts. By providing an extended dataset and associated models, this work advances the understanding needed to design energy-efficient, corrosion mitigating LDAC system.

36 MATERIALS SCIENCE↗

The architecture of resilience: a genome assembly of Myrothamnus flabellifolia sheds light on desiccation tolerance and sex determination

Myrothamnus flabellifolia is a dioecious resurrection plant endemic to southern Africa that has become an important model for understanding desiccation tolerance. Despite its ecological and medicinal significance, genomic and transcriptomic resources for the species are limited. We generated a chromosome-level, haplotype-resolved reference genome assembly and annotation for M. flabellifolia and conducted transcriptomic profiling across a natural dehydration–rehydration time course in the field. Genome architecture and sex determination were characterized, and co-expression network and cis-regulatory element (CRE) enrichment analyses were used to investigate dynamic responses to desiccation. The 1.28-Gb genome exhibits unusually consistent chromatin architecture with unique chromosome organization across highly divergent haplotypes. We identified an XY sexual system with a small sex-determining region on Chromosome 8. Transcriptomic responses varied with dehydration severity, pointing to early suppression of growth, progressive activation of protective mechanisms, and subsequent return to homeostasis upon rehydration. Late embryogenesis abundant and early light-induced protein transcripts were dynamically regulated and showed enrichment of abscisic acid and stress-responsive CREs pointing toward conserved responses. Together, this study provides foundational resources for understanding the genomic architecture and reproductive biology of M. flabellifolia and offers new insights into the mechanisms of desiccation tolerance.

chromosome structure↗

Design of a Proportional-Control-Based Advanced Control Strategy for Independent Temperature and Humidity Control of a Pre-Cooled Desiccant Air Cooling System

In this study, the control of a desiccant-wheel-based evaporative cooling system with a double-layer dew-point cooler system is emphasized. There are two dew-point evaporative coolers in the system and the air taken inside is subjected to pre- and post-cooling processes. The dehumidification process of the air taken in is carried out by the desiccant wheel after the pre-cooling process. A proportional-based control strategy has been developed to adjust the temperature and relative humidity of the room quickly and robustly with different operation modes for actuators to bring comfort with less energy consumption. In addition, an automatic Stop/Run mode has been added to the control strategy to save extra energy. With the developed control strategy, enabling the actuators to switch between the operation modes, more energy savings are achieved compared to both traditional ON/OFF and proportional controls. The accuracy and applicability of the developed control strategy were analyzed and it was observed that the room comfort reached the desired levels successfully under all disruptive effects. The control inputs and the energies consumed by all the actuators were investigated and it was determined that 21.19% more energy savings are provided by adding the automatic Stop/Run feature. With the multi-mode control strategy, a total of 40.90% less energy consumption is achieved compared to the classical ON/OFF control technique. Thus, it is seen that the controller developed for the desiccant-wheel-based evaporative cooler is a viable method to provide fast and robust comfort conditions with less energy.

42 ENGINEERING↗

Corrosion of Metal Alloys in Potassium Acetate Solutions for Liquid Desiccant Dehumidification and Air Conditioning

For commercial buildings, liquid desiccant air conditioners (LDACs) could provide up to 80% energy savings compared to high-efficiency vapor compression AC, but commonly utilized liquid desiccants are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Less corrosive alternatives are sought. Here, potassium acetate solutions are investigated as less-corrosive alternatives to the chloride salt solutions that are typically used in LDAC systems. Corrosion evaluations for a Cu alloy (C12200) and two Al alloys (Al3003 and Al1100) in both potassium acetate and chloride salt solutions are presented. We show that yearly corrosion rates are lower in potassium acetate solutions by up to three orders of magnitude. Active corrosion behavior is largely absent in potassium acetate solutions but is present in chloride salt solutions. Furthermore, solid corrosion products are observed in chloride salt solutions. Thus, we conclude that potassium acetate is a promising candidate as a less corrosive alternative liquid desiccant for LDAC systems with metallic components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Desiccation and rehydration dynamics in the epiphytic resurrection fern Pleopeltis polypodioides

The epiphytic resurrection—or desiccation-tolerant (DT)—fern Pleopeltis polypodioides can survive extreme desiccation and recover physiological activity within hours of rehydration. Yet, how epiphytic DT ferns coordinate between deterioration and recovery of their hydraulic and photosynthetic systems remains poorly understood. We examined the functional status of the leaf vascular system, chlorophyll fluorescence, and photosynthetic rate during desiccation and rehydration of P. polypodioides. Xylem tracheids in the stipe embolized within 3–4 h during dehydration. When the leaf and rhizome received water, tracheids refilled after ~24 h, which occurred along with dramatic structural changes in the stele. Photosynthetic rate and chlorophyll fluorescence recovered to predesiccation values within 12 h of rehydration, regardless of whether fronds were connected to their rhizome. Our data show that the epiphytic DT fern P. polypodioides can utilize foliar water uptake to rehydrate the leaf mesophyll and recover photosynthesis despite a broken hydraulic connection to the rhizome.

59 BASIC BIOLOGICAL SCIENCES↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Soil Desiccation Treatability Testing at BC Waste Disposal Cribs

During Hanford’s production period, low-level waste products generated from chemical processing of uranium fuel rods were discharged directly to the ground through a system of cribs and trenches located in the 200-BC-1 Operable Unit (OU). The site consists of 6 cribs and 20 trenches that received more than 117,000 m3 of radioactive liquid waste discharged to the soil. These unlined infiltration galleries held volumes of liquid waste while it seeped into the ground, with the understanding that the 100 m (330 ft) thick vadose zone in the area would effectively capture the effluent and prevent groundwater impacts. A conceptual model showing the operation of cribs and trenches is shown in Figure 1. Data show effluent from the 26 cribs and trenches containing about 410 curies of Technetium-99 (Tc-99) is primarily located between 30 m and 70 m (98 ft and 230 ft) depth (Corbin et al., 2005; Ward et al., 2004). Despite no evidence indicating that the contamination has reached the groundwater at BC cribs and trenches, the mobility of Tc-99 had been demonstrated in laboratory tests and was recognized as a threat to groundwater at the site. Using data from numerical models, laboratory analyses, field investigations, and information on historical discharges, the EPA and Ecology identified Tc-99 and U contamination of the vadose zone as a remediation priority. The U.S. DOE was notified by EPA and Ecology regarding risks associated with Tc-99 contamination in a letter requesting development of a strategy for improved methods to understand the nature and extent of vadose zone contamination, specifically Tc-99, and to develop remedial options for addressing such contamination. To develop the appropriate technology for characterizing, remediating, and monitoring the deep vadose zone Tc-99 contamination, the U.S. DOE worked with the EPA and Ecology to create a Treatability Test Plan under a Remedial Investigation/Feasibility Study (RI/FS) for the Hanford 200 Areas. Under this RI/FS, it was determined that a treatability test for soil desiccation should be carried out as it was identified as a promising in-situ treatment technology for mitigating risks posed by Tc-99 contamination to the groundwater table. The BC Cribs and Trenches site was identified as a representative site for Tc-99 and U contamination and selected for the soil desiccation treatability test. In this chapter, we summarize the overlying regulatory framework of RI/FS and treatability tests and illustrate how development and experimentation supported the evaluation of selected remedies. We briefly discuss the RI/FS for the 200 Areas of the Hanford Site and focus on the soil desiccation treatability testing performed at the BC cribs and trenches site under the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau (DVZ-TT). The DVZ-TT is one component of the remedial investigation/feasibility study for the Hanford 200 Areas and represents the underlying regulatory framework that drives site operations towards records of decision and site closure.

Mangel, Adam R.↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

The physics of desiccation cracks 2: Modeling and prediction of the crack patterns

Here, this paper extends the experimental results of our companion paper by modeling and predicting the onset and pattern formation of desiccation cracks in geomaterials (Ruoyu et al., 2023). Thin-layer silt samples in controlled atmospheric conditions were tested to obtain the surface strain maps with the digital image correlation (DIC) method during dehydration. Support experiments, including consolidation and displacement-controlled triaxial tests, were conducted for the properties of geomaterials. These experimental results were used to validate a viscoplastic theoretical model by comparing cracks and singularities locations that distribute following the Cnoidal wave pattern. A critical value exists in the viscoplastic model that determines the number of singularities, which accurately predicts the number of cracks in the experiment. The critical values contain two crucial parameters: rate sensitivity and λ. Rate sensitivity describes the rate-dependent stress–strain relation, while λ shows the ability of pore pressure redistribution under the external mechanical loading rate. These results provide a new view to analyze the desiccation cracks considering the rate-dependent viscoplasticity.

42 ENGINEERING↗

Anatomical and hydraulic responses to desiccation in emergent conifer seedlings

Premise The young seedling life stage is critical for reforestation after disturbance and for species migration under climate change, yet little is known regarding their basic hydraulic function or vulnerability to drought. Here, we sought to characterize responses to desiccation including hydraulic vulnerability, xylem anatomical traits, and impacts on other stem tissues that contribute to hydraulic functioning. Methods Larix occidentalis , Pseudotsuga menziesii , and Pinus ponderosa (all ≤6 weeks old) were imaged using x‐ray computed microtomography during desiccation to assess seedling biomechanical responses with concurrently measured hydraulic conductivity ( k s ) and water potential ( Ψ ) to assess vulnerability to xylem embolism formation and other tissue damage. Results In non‐stressed samples for all species, pith and cortical cells appeared circular and well hydrated, but they started to empty and deform with decreasing Ψ which resulted in cell tearing and eventual collapse. Despite the severity of this structural damage, the vascular cambium remained well hydrated even under the most severe drought. There were significant differences among species in vulnerability to xylem embolism formation, with 78% xylem embolism in L. occidentalis by Ψ of −2.1 MPa, but only 47.7% and 62.1% in P. ponderosa and P. menziesii at −4.27 and −6.73 MPa, respectively. Conclusions Larix occidentalis seedlings appeared to be more susceptible to secondary xylem embolism compared to the other two species, but all three maintained hydration of the vascular cambium under severe stress, which could facilitate hydraulic recovery by regrowth of xylem when stress is relieved.

Miller, Megan L.↗

Mass spectrometry and spectroscopic characterization of a tetrameric photosystem I supercomplex from Leptolyngbya ohadii , a desiccation-tolerant cyanobacterium

Cyanobacteria inhabiting desert biological soil crusts face the harsh conditions of the desert. They evolved a suite of strategies toward desiccation-hydration cycles mixed with high light irradiations, etc. In this study we purified and characterized the structure and function of Photosystem I (PSI) from Leptolyngbya ohadii, a desiccation-tolerant desert cyanobacterium. We discovered that PSI forms tetrameric (PSI-Tet) aggregate. We investigated it by using sucrose density gradient centrifugation, clear native PAGE, high performance liquid chromatography, mass spectrometry (MS), time-resolved fluorescence (TRF) and time-resolved transient absorption (TA) spectroscopy. MS analysis identified the presence of two PsaB and two PsaL proteins in PSI-Tet and uniquely revealed that PsaLs are N-terminally acetylated in contrast to non-modified PsaL in the trimeric PSI from Synechocystis sp. PCC 6803. Chlorophyll (Chl) a fluorescence decay profiles of the PSI-Tet performed at 77 K revealed two emission bands at ∼690 nm and 725 nm with the former appearing only at early delay time. The main fluorescence emission peak, associated with emission from the low energy Chls a, decays within a few nanoseconds. TA studies demonstrated that the 725 nm emission band is associated with low energy Chls a with absorption band clearly resolved at ∼710 nm at 77 K. As a result, our work suggests that the heterogenous composition of PsaBs and PsaL in PSI-Tet is related with the adaptation mechanisms needed to cope with stressful conditions under which this bacterium naturally grows.

59 BASIC BIOLOGICAL SCIENCES↗

"Self-packaging" desiccant

Desiccant, consisting of water-soluble filler contained in water-permeable elastomeric matrix, absorbs large quantities of water without becoming sticky or releasing corrosive agents. Desiccant may be molded into virtually any shape depending on area of application.

Fedors, R. F.↗

Investigation of Desiccants and CO2 Sorbents for Advanced Exploration Systems 2015-2016

Design of advanced carbon dioxide removal systems begins with the study of sorbents. Specifically, new CO2 sorbents and desiccants need to be studied to enable greater productivity from existing and future spaceflight systems. This presentation will discuss the studies used as input for selecting future CO2 sorbent materials. Also, the adjoining issues of understanding the effects of water co-adsorption and material selection for desiccant beds will be discussed. Current sorbents for CO2 removal are based on 5A zeolites, but a transition to sorbents derived from 13X will be necessary as CO2 levels in cabin air become leaner. Unfortunately, these 13X zeolites are more susceptible to long-term performance loss due to water co-adsorption than 5A due at achievable regeneration temperatures. A study on how impactful the presence of trace water will be to the cyclic operation of small-scale beds will be discussed. Also, methods to recover the performance of beds in a space environment after a major moisture adsorption event will be discussed. The information obtained from the water co-adsorption studies will play a major part in selecting a CO2 sorbent for advanced removal systems. Pellet structural properties play another major role in the selection process. One factor for long-term, hands-off operation of a system is pellet integrity. Maintaining integrity means preventing pellet fracture and the generation of fines due to various thermal and mechanical means which would eventually clog filters or damage downstream systems. Either of these problems require significant shutdowns and maintenance operations and must be avoided. Therefore, study of high-integrity pellets and design of new pellets will be discussed.

Knox, James C.↗