Search NASA⌕ Search

SEARCH · Search NASA

Results for “Desiccant systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of Desiccants and CO2 Sorbents for Advanced Exploration Systems 2016-2017

Advanced Environmental Control and Life Support System (ECLSS) design is critical for manned space flight beyond Earth. Current systems enable extended missions in low-Earth orbit, but for deep-space missions, not only will astronauts be outside the reach of resupply operations from Earth but they will also need to handle malfunctions and compensate for the degradation of materials. These two daunting challenges must be overcome for long-term independent space flight. In order to solve the first, separation and recycling of onboard atmosphere is required. Current systems utilize space vacuum to fully regenerate CO2 sorbent beds, but this is not sustainable. The second challenge stems from material and performance degradation due to operational cycling and on-board contaminants. This report will review the recent work by the ECLSS team at Marshall Space Flight Center towards overcoming these challenges by characterizing materials via novel methods and by assessing new air revitalization systems.

Knox, Jim↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen/Metal Hydride Based Heat Pump System for Large HVAC Applications Utilizing an Ionic Liquid Desiccant Subsystem [Slides]

A multi-stage electrochemical hydrogen compressor incorporates membrane-electrode-assemblies (MEAs) separated by proton exchange membranes (PEMs) in series to reach higher pressures, when a current is passed through the MEA protons and electrons are generated at the anode. The protons are electrochemically driven across the membrane to the cathode, after which they combine with the rerouted electrons to form hydrogen, which is fed to the hydrogen compressor to be oxidized at the anode of each cell to form protons and electrons. This type of compressor has no moving parts and can be applied to refrigeration systems technologies. This project investigated the viability of commercialization of heat pumps based on electrochemical compressor technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype solar heating and cooling systems, including potable hot water

Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.

Bloomquist, D.↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Method and system for dehumidification and atmospheric water extraction with minimal energy consumption

Methods, systems and devices for managing humidity within an HVAC system including a nanostructured desiccant porous material configured to adsorb water from an inlet stream at a first air pressure and to release water from that material when subjected to a second air pressure when the second air pressure is lower than the first air pressure is located within a particular location so as to allow for the passage of wet air over the materials and allow adsorption of the water on to the material. When coupled with a vacuum pump water can be collected and released from the materials and the system, regenerating the material for future use and removing water from a stream at a significantly lower cost than existing processes.

McGrail, Bernard P.↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long Duration Sorbent Testbed

The Long Duration Sorbent Testbed (LDST) is a flight experiment demonstration designed to expose current and future candidate carbon dioxide removal system sorbents to an actual crewed space cabin environment to assess and compare sorption working capacity degradation resulting from long term operation. An analysis of sorbent materials returned to Earth after approximately one year of operation in the International Space Station's (ISS) Carbon Dioxide Removal Assembly (CDRA) indicated as much as a 70% loss of working capacity of the silica gel desiccant material at the extreme system inlet location, with a gradient of capacity loss down the bed. The primary science objective is to assess the degradation of potential sorbents for exploration class missions and ISS upgrades when operated in a true crewed space cabin environment. A secondary objective is to compare degradation of flight test to a ground test unit with contaminant dosing to determine applicability of ground testing.

Howard, David F.↗

Long Duration Sorbent Testbed

The LDST is a flight experiment demonstration designed to expose current and future candidate carbon dioxide removal system sorbents to an actual crewed space cabin environment to assess and compare sorption working capacity degradation resulting from long term operation. An analysis of sorbent materials returned to earth after approximately one year of operation in the International Space Station's (ISS) Carbon Dioxide Removal Assembly (CDRA) indicated as much as a 70% loss of working capacity of the silica gel desiccant material at the extreme system inlet location, with a gradient of capacity loss down the bed. The primary science objective is to assess the degradation of potential sorbents for exploration class missions and ISS upgrades when operated in a true crewed space cabin environment. A secondary objective is to compare degradation of flight test to a ground test unit with contaminant dosing to determine applicability of ground testing.

Knox, James↗

Innovative Air Conditioning and Climate Control

NASA needed to develop a desiccant wheel based humidity removal system to enable the long term testing of the Orion CO2 scrubber on the International Space Station. In the course of developing that system, we learned three things that are relevant to energy efficient air conditioning of office towers. NASA developed a conceptual design for a humidity removal system for an office tower environment. We are looking for interested partners to prototype and field test this concept.

Graf, John↗

Desiccation and rehydration dynamics in the epiphytic resurrection fern Pleopeltis polypodioides

The epiphytic resurrection—or desiccation-tolerant (DT)—fern Pleopeltis polypodioides can survive extreme desiccation and recover physiological activity within hours of rehydration. Yet, how epiphytic DT ferns coordinate between deterioration and recovery of their hydraulic and photosynthetic systems remains poorly understood. We examined the functional status of the leaf vascular system, chlorophyll fluorescence, and photosynthetic rate during desiccation and rehydration of P. polypodioides. Xylem tracheids in the stipe embolized within 3–4 h during dehydration. When the leaf and rhizome received water, tracheids refilled after ~24 h, which occurred along with dramatic structural changes in the stele. Photosynthetic rate and chlorophyll fluorescence recovered to predesiccation values within 12 h of rehydration, regardless of whether fronds were connected to their rhizome. Our data show that the epiphytic DT fern P. polypodioides can utilize foliar water uptake to rehydrate the leaf mesophyll and recover photosynthesis despite a broken hydraulic connection to the rhizome.

59 BASIC BIOLOGICAL SCIENCES↗

Cost analysis of carbon dioxide concentrators

A methodology is developed to predict the relevant contributions of the more intangible cost elements encountered in the development of flight-qualified hardware and is used to predict the costs of three carbon dioxide concentration systems. The cost and performance data from Gemini, Skylab, and other programs are utilized as a basis for establishing the cost estimating relationships. The concentration systems analyzed are the molecular sieves C02 concentrator, the hydrogen-depolarized concentrator, and the regenerable solid desiccant concentrator. Besides the cost estimates for each system, their comparative criteria including relative characteristics, operational differences, and development status are considered.

Yakut, M. M.↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗