Hydrogen desorption from the surface and subsurface of cobalt

The influence of coverage on the diffusion of hydrogen into the subsurface of cobalt was studied using density functional theory (DFT) and temperature programmed desorption (TPD). DFT calculations show that as the hydrogen coverage on Co(0001) increases, the barrier for hydrogen diffusion into the bulk decreases by 20%. Additionally, subsurface hydrogen on a hydrogen covered surface was found to be more stable when compared to a clean cobalt surface. To test these theoretical findings experimentally, excited hydrogen was used in an ultra-high vacuum environment to access higher hydrogen coverages. Here, our TPD studies showed that at high hydrogen coverages, a sharp low temperature feature appeared, indicating the stabilization of subsurface hydrogen. Further DFT calculations indicate that this sharp low temperature feature results from associative hydrogen desorption from a hydrogen saturated surface with a population of subsurface hydrogen. Microkinetic modelling was used to model the TPD spectra for hydrogen desporption from cobalt with and without subsurface hydrogen, showing reasonable agreement with experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Symmetry-resolved CO desorption and oxidation dynamics on O/Ru(0001) probed at the C K-edge by ultrafast X-ray spectroscopy

In this work, we report on carbon monoxide desorption and oxidation induced by 400 nm femtosecond laser excitation on the O/Ru(0001) surface probed by time-resolved X-ray absorption spectroscopy (TR-XAS) at the carbon K-edge. The experiments were performed under constant background pressures of CO (6x10 -8 Torr) and O 2 (3x10 -8 Torr). Under these conditions, we detect two transient CO species with narrow 2π* peaks, suggesting little 2π* interaction with the surface. Based on polarization measurements, we find that these two species have opposing orientations: (1) CO favoring a more perpendicular orientation and (2) CO favoring a more parallel orientation with respect to the surface. We also directly detect gas-phase CO 2 using a mass spectrometer and observe weak signatures of bent adsorbed CO 2 at slightly higher X-ray energies than the 2π* region. These results are compared to previously reported TR-XAS results at the O K-edge where the CO background pressure was three times lower (2x10 -8 Torr) while maintaining the same O 2 pressure. At the lower CO pressure, in the CO 2π* region, we observed adsorbed CO and a distribution of OC-O bond lengths close to the CO oxidation transition state, with little indication of gas-like CO. The shift towards 'gas-like' CO species may be explained by the higher CO exposure, which blocks O adsorption, decreasing O coverage and increasing CO coverage. These effects decrease the CO desorption barrier through dipole-dipole interaction, while simultaneously increasing the CO oxidation barrier.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Hydrogen Reaction-Induced Water Desorption from Oxide-Passivated Metal Surfaces for Plasma Applications

Elucidating the mechanisms responsible for sub-microsecond desorption of water and other impurities from electrode surfaces at high heating rates is crucial for understanding pulsed power behavior. Ionization of desorbed impurities in the vacuum regions causes power or current loss; devising methods to limit such desorption during the short time scale of pulsed power is needed to improve corresponding applications. Previous molecular modeling studies have strongly suggested that, under high vacuum conditions, the amount of water impurity desorbing from oxide surfaces on metal electrodes is at a sub-monolayer level at room temperature, which appears insufficient to explain observed pulsed power energy losses at high current densities. In this work, we apply Density Functional Theory (DFT) techniques to show that hydrogen trapped inside iron metal can diffuse into hematite (α-Fe 2 O 3 ) on the metal surface, ultimately reacting with the oxide to form Fe(II) and H 2 O. The latter desorbs at elevated temperature and may explain the anomalous amount of desorbed impurity inferred from pulsed-power experiments. We also apply a suite of characterization techniques to demonstrate that when iron metal is heated to 650 °C, the dominant surface oxide component becomes α-Fe 2 O 3 . The oxide facets exposed are found to be a mixture of (0001), (10-10), and others, in agreement with the DFT models used.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous Absorption and Desorption Isotherms of Various Hydrogen and Deuterium Mixtures between 20 and 120 °C Are Used to Determine the Activity Coefficients for Palladium-Hydride Solutions

A test bed was constructed to measure the absorption and desorption isotherms for palladium hydride using H 2 , D 2 , and various H 2 /D 2 mixtures for temperatures in the range 20 °C ≤ T ≤ 120 °C. The pressure–composition–temperature isotherms were measured. The pressures obtained with mixtures between each pure isotope were monotonic, yet nonlinear. This nonlinear dependence of total pressure with feed gas protium concentration reveals the mixed isotope hydride system behaves nonideally. A thermodynamic model was adapted from the literature, which accounts for the nonideal nature of the mixed-isotope system. The measured data were used as constraints in this model in order to calculate the protium mole fractions in the hydride phase and the protium activity coefficients for palladium hydride at various temperatures and protium concentrations in the system. Knowing the protium mole fraction and activity coefficients allows for a priori calculation of the isotopologue distribution in the gas phase and the isotope distribution in the hydride phase, given a palladium temperature and equilibrium pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovering CO Adsorption and Desorption Pathways from Chemical Reaction Neural Network Modeling of Transient Kinetics Spectroscopy

Here, we demonstrate a data-driven approach to interpreting surface reactions by combining time-resolved gas pulsing infrared spectroscopy with chemical reaction neural networks (CRNNs). Using CO adsorption and desorption on Pd(111) at 460–490 K as a model system, we show how transient kinetic data can reveal detailed reaction mechanisms. Starting with a simple one-species model, we systematically evaluate increasingly complex mechanisms involving hollow and bridge site adsorption. Despite the similar goodness of fit to the same experimental absorbance data, our models predict distinct coverage dynamics for different adsorption sites. Through analysis of spectral peak stability and predicted dynamics, we identify a mechanism in which CO primarily adsorbs on bridge sites followed by rapid conversion to hollow sites as being the most physically consistent with experimental observations. This work provides a framework for extracting mechanistic insights from limited experimental data, demonstrating how machine learning can bridge the gap between transient kinetic measurements and a molecular-level understanding of surface reactions.

36 MATERIALS SCIENCE↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ligand Desorption and Fragmentation in Oleate-Capped CdSe Nanocrystals under High-Intensity Photoexcitation

Semiconductor nanocrystals (NCs) offer prospective use as active optical elements in photovoltaics, light-emitting diodes, lasers, and photocatalysts due to their tunable optical absorption and emission properties, high stability, and scalable solution processing, as well as compatibility with additive manufacturing routes. Over the course of experiments, during device fabrication, or while in use commercially, these materials are often subjected to intense or prolonged electronic excitation and high carrier densities. The influence of such conditions on ligand integrity and binding remains underexplored. Here, in this study, we expose CdSe NCs to laser excitation and monitor changes in oleate that is covalently attached to the NC surface using nuclear magnetic resonance as a function of time and laser intensity. Higher photon doses cause increased rates of ligand loss from the particles, with upward of 50% total ligand desorption measured for the longest, most intense excitation. Surprisingly, for a range of excitation intensities, fragmentation of the oleate is detected and occurs concomitantly with formation of aldehydes, terminal alkenes, H 2 , and water. After illumination, NC size, shape, and bandgap remain constant although low-energy absorption features (Urbach tails) develop in some samples, indicating formation of substantial trap states. The observed reaction chemistry, which here occurs with low photon to chemical conversion efficiency, suggests that ligand reactivity may require examination for improved NC dispersion stability but can also be manipulated to yield desired photocatalytically accessed chemical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared reflection absorption spectroscopy and temperature-programmed desorption studies of CO adsorption on Ni/CeO 2 (111) thin films: The role of the ceria support

Ceria-supported Ni has shown unique catalytic activity due to unique properties of small Ni particles and strong metal-support interaction. Identification of adsorption sites and understanding the chemical interaction over Ni-ceria at the fundamental level provide crucial insights into the reaction pathways of complex catalytic processes. In this study, to probe the surface sites, the adsorption of CO was carried out with model Ni/ceria systems consisting of Ni nanoparticles vapor-deposited on well-ordered CeO x (111) (1.5 < x < 2) thin films using infrared reflection absorption spectroscopy (IRRAS) and temperature-programmed desorption (TPD) under ultrahigh vacuum (UHV) conditions. Fully oxidized CeO 2 (111) (Ce 4+ ) and partially reduced CeO 1.75 (111) (Ce 4+ /Ce 3+ ) thin films were grown on Ru(0001) to examine the role of the ceria support. Additionally, Ni with low coverages (e.g., 0.2 ML) grows forming small two-dimensional particles on ceria at 300 K, which develop into three-dimensional clusters after heating to 700 K. In the absence of Ni, CO adsorption at 1 mTorr at 100 K shows distinct IR bands at 2158 cm -1 on CeO 2 and 2165 cm -1 on CeO 1.75 . Bridging and atop IR bands associated with CO adsorption over metallic Ni were observed on the Ni-CeO 1.75 surface at 300 K under UHV conditions. CO adsorption over Ni 0 was also observed over as-deposited Ni on CeO 2 . However, a new IR band at 2146 cm -1 due to CO adsorption over Ni 2+ species was detected at 100 K over the annealed Ni particles on CeO 2 . CO IRRAS data suggest the oxidation of Ni to Ni 2+ on CeO 2 and the formation of predominant Ni 2+ species with heating, which is further confirmed with CO TPD data and previous x-ray photoelectron spectroscopy results.

36 MATERIALS SCIENCE↗

In-Situ Laser-Induced-Desorption-Spectroscopy Diagnostic Deployment on the Linear Plasma Device CSDX

A calibrated laser induced desorption diagnostic (LIDS) concept is developed under this award for application to fusion relevant plasma materials interactions studies. Small areal amounts of hydrogenic release from a deuterium filled PMI target are measured and quantified when irradiated by a LID flash heat event on the target surface. Good success was demonstrated by this project with the PISCES-E rf plasma device at UCSD by fully quantified measurement and removal of D from W-D co-deposit layers in experiments. However, adapting the LIDS technique to D plasma exposed W targets in the linear plasma CSDX device, now labelled PISCES-Rf, was prone to several technical challenges ranging from target line of sight access, laser focusing, and loss of optical spectroscopic signal strength in the larger PISCES-Rf vacuum system. The results are summarized in this report.

08 HYDROGEN↗

Particle composition measurements for ultrafine particles collected at the EPCAPE Mount Soledad site from 04-27-2023 to 06-13-2023 using a Thermal Desorption Chemical Ionization Mass Spectrometer

The dataset contains particle composition data for both the positive and negative reagent ion modes of the Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS). The dataset is split into two directories: one for particles with diameters of 30 nm and the other for particles with diameters of less than 100 nm. The positive reagent ion mode uses H3O+ as the reagent ion, and ionization usually occurs through hydrogen addition. The negative mode uses O2- as the reagent ion. Negative mode ionization generally occurs through hydrogen abstraction, but O2- addition is also possible. Ion concentrations were normalized to total ion counts, and unknown ions were then removed from the data. The name of each ion fraction time series includes the mass to charge ratio and the chemical formula for the ion. Time is recorded in seconds since 1/1/1904. The time zone is UTC.

54 ENVIRONMENTAL SCIENCES↗

Quantification of Brønsted Acid Sites in Zeolites by Water Desorption Thermogravimetry

The many studies that have been conducted on water adsorption on zeolites were carried out in “adsorption” mode, from adsorption isotherms or single-point measurements, with the samples being first degassed at high temperature, and then exposed to water vapor at variable partial pressure. Here, we report Thermogravimetric Analysis (TGA) studies of HZSM-5 saturated with water at room temperature, thus studying water adsorption in “desorption” mode. In this work, TGA was used to ascertain the amount of water remaining as a function of the pretreatment temperature, and to identify the temperature at which one water molecule per framework Al atom persists. Solid-state 1H NMR spectroscopy, combined with molecular modeling, provided evidence for water molecules hydrogen bonded to Brønsted acid sites and formation of oxonium species for distinct water per framework Al atom. TGA is shown to be a simple and expeditious technique to measure the number of Brønsted acid sites in aluminosilicate zeolites, with advantages over the traditional methods of IR or TPD of dangerous adsorbed ammonia or pyridine. TGA of adsorbed water also provides information on the water clusters formed at the acid sites of HZSM-5, which are proportional to the number of acid sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatility Basis Set Distributions and Viscosity of Organic Aerosol Mixtures: Insights from Chemical Characterization Using Temperature-Programmed Desorption–Direct Analysis in Real-Time High-Resolution Mass Spectrometry

Quantitative assessment of gas-particle partitioning of individual components within complex atmospheric organic aerosols (OA) mixtures is critical for predicting and comprehending the formation and evolution of OA particles in the atmosphere. This investigation leverages previously documented data obtained through a temperature programmed desorption - direct analysis in real time – high resolution mass spectrometry (TPD-DART-HRMS) platform. This methodology facilitates the bottom-up construction of volatility basis set (VBS) distributions for constituents found in three biogenic secondary organic aerosol (SOA) mixtures produced through the ozonolysis of a-pinene, limonene, and ocimene. The apparent enthalpies (ΔH*, kJ mol -1 ) and saturated vapor mass concentrations (C T *, µg∙m -3 ) of individual SOA components, determined as a function of temperature (T, K), facilitated an assessment of changes in VBS distributions and gas-particle partitioning with respect to T and atmospheric total organic mass loadings (tOM, µg∙m -3 ). Further, the VBS distributions reveal distinct differences in volatilities among monomers, dimers, and trimers, enabling their categorization into separate volatility bins. At the ambient temperature of T = 298 K, only monomers efficiently partition between gas and particle phases across a broad range of atmospherically relevant total organic mass loadings (tOM) values of 1–100 µg∙m -3 . Partitioning of dimers and trimers becomes notable only at T > 360 K and T > 420 K, respectively. The viscosity of SOA mixtures is assessed using a bottom-up calculation approach, incorporating the input of elemental formulas, ΔH*, C T *, and particle-phase mass fractions of the SOA components. Through this approach, we are able to accurately estimate the variations in SOA viscosity that result from the evaporation of its components. These variations are, in turn, influenced by atmospherically relevant changes in tOM and T. Comparison of the calculated SOA viscosity and diffusivity values with literature reported experimental results shows close agreement, thereby validating the employed calculation approach. These findings underscore the significant potential for TPD-DART-HRMS measurements in enabling the untargeted analysis of organic molecules within OA mixtures. This approach facilitates quantitative assessment of their gas-particle partitioning and allows for the estimation of their viscosity and condensed-phase diffusion, thereby contributing valuable insights to atmospheric models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating the Adsorption–Desorption Kinetics of a Molecular Water Oxidation Catalyst at an Electrode Interface

Probing the dynamics of molecular catalysts at electrode–electrolyte interfaces is essential for understanding catalytic mechanisms. Structure-specific spectroscopic methods are particularly powerful for examining electrocatalytic interfaces but are mostly used under steady-state conditions. Herein, we combined surface-enhanced infrared absorption spectroscopy (SEIRAS) with phase-sensitive detection (PSD) to investigate the dynamics of a molecular Ir-based water oxidation catalyst at the Au–electrolyte interface. We found that the amplitude of the absorbance of the catalyst is anticorrelated to that of interfacial water. This anticorrelation can be understood by the adsorption of the electrooxidized catalyst on the electrode and concurrent displacement of interfacial water. The infrared signals from the interface exhibit an increasing phase lag with respect to the electrode potential with an increasing scan rate of the potential. Kinetic modeling suggests that the potential-dependent adsorption–desorption kinetics of the molecular catalyst on the electrode gives rise to this phase lag. Furthermore, this study shows that PSD-SEIRAS is a powerful tool for investigating the interfacial dynamics of electrocatalytic systems.

Catalysts↗

A Fast-Pass, Desorption Electrospray Ionization Mass Spectrometry Strategy for Untargeted Metabolic Phenotyping

Desorption electrospray ionization mass spectrometry imaging (DESI-MSI) provides direct analytical readouts of small molecules that can be used to characterize the metabolic phenotypes of genetically engineered bacteria. In an effort to accelerate the time frame associated with the screening of mutant libraries, we have developed a high-throughput DESI-MSI analytical workflow implementing a single raster line-scan strategy that facilitates the collection of location-resolved molecular information from engineered strains on a subminute time scale. Evaluation of this “Fast-Pass” DESI-MSI phenotyping workflow on analytical standards demonstrated the capability of acquiring full metabolic profiling information with a throughput of ~40 s per sample. This Fast-Pass strategy was implemented in the analysis of genetically edited Escherichia coli strains that have been engineered to produce various free-fatty acids (FFAs) for applications relevant to biofuels. Due to the untargeted nature of DESI-MSI, the investigation of these strains yielded molecular information for both global metabolites and targeted detection of accumulated bioproducts, allowing simultaneous readouts of strain-specific chemical profiles and comparative measurements of FFA production levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%–70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

DESI↗