Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparison of MPEG-1 digital videotape with digitized sVHS videotape for quantitative echocardiographic measurements

Digital format is rapidly emerging as a preferred method for displaying and retrieving echocardiographic studies. The qualitative diagnostic accuracy of Moving Pictures Experts Group (MPEG-1) compressed digital echocardiographic studies has been previously reported. The goals of the present study were to compare quantitative measurements derived from MPEG-1 recordings with the super-VHS (sVHS) videotape clinical standard. Six reviewers performed blinded measurements from still-frame images selected from 20 echocardiographic studies that were simultaneously acquired in sVHS and MPEG-1 formats. Measurements were obtainable in 1401 (95%) of 1486 MPEG-1 variables compared with 1356 (91%) of 1486 sVHS variables (P <.001). Excellent agreement existed between MPEG-1 and sVHS 2-dimensional linear measurements (r = 0.97; MPEG-1 = 0.95[sVHS] + 1.1 mm; P <.001; Delta = 9% +/- 10%), 2-dimensional area measurements (r = 0.89), color jet areas (r = 0.87, p <.001), and Doppler velocities (r = 0.92, p <.001). Interobserver variability was similar for both sVHS and MPEG-1 readings. Our results indicate that quantitative off-line measurements from MPEG-1 digitized echocardiographic studies are feasible and comparable to those obtained from sVHS.

NASA Discipline Cardiopulmonary↗

SymPLe 1131: A novel architectural solution for the realization of verifiable digital I and C systems and embedded digital devices - 387

One of the main reasons for the increasing popularity of FPGAs in embedded systems and digital I and C systems is that they provide many of the advantages from both hardware and software components. FPGAs provide configurability approaching that of SW, while at the same time delivering deterministic behavior of pure hardware solutions. However, with regard to Software Common Cause Failures (CCF), the use of FPGAs in digital I and C platforms should not be seen as plug-in remedy for reduction or elimination of CCF. To address CCF, we argue that it is not enough to manage the complexity of an I and C device or system, but we must also have the ability to constrain complexity (as needed) and rigorously reason about execution and device functionality. This paper presents the work done regarding an FPGA overlay architecture called SymPLe. SymPLe is designed to reduce the gap between software and hardware approaches for digital I and C systems and increases deterministic behavior and verifiability of the application, architecture and safety-critical system while reasoning about CCF. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Dynamic shear localization of a titanium alloy under high-rate tension characterized by x-ray digital image correlation

Highlights: • First systematic error analyses for XDIC • First XDIC study of Ti-6Al-4V under dynamic tension • Deformation mode transition induces dynamic ductility decrease. • Dynamic shear localization due to rate-dependent microvoid coalescence process. - Abstract: Dynamic and quasi-static tension experiments are conducted on Ti-6Al-4V alloys, with in situ, synchrotron-based, high-speed, x-ray phase contrast imaging implemented to characterize the dynamic deformation and fracture process of Ti alloys at the Advanced Photon Source. X-ray digital imaging correlation (XDIC) is applied for strain field mapping. The size distribution of x-ray speckles are quantified via a morphological analysis, with a mean of ∼20 μm. Systematic error analyses of displacement and strain field measurements are firstly conducted for XDIC, and demonstrate that the displacement and strain errors can be controlled below 0.01 pixel and 0.1%, respectively. Mesoscale strain characteristics measured via XDIC are consistent with and reveal mechanisms for the bulk-scale stress–strain responses. Under dynamic tension, a sharp transition to strain softening occurs when the bulk strain exceeds about 0.04, which leads to a lower dynamic fracture strain (0.08) than the quasi-static one (0.1). The corresponding strain filed mapping demonstrates that shear deformation localizations grow and coalesce rapidly into a narrow shear deformation band under dynamic loading, while tensile deformation and necking progresses gradually under quasi-static loading. Scanning electron microscopy shows that void nucleation occurs mainly at the interface of α and β phases for both quasi-static and dynamic tension. However, microvoids coalesce preferentially along colony boundaries or the boundary α phase under quasi-static tension, but along the maximum shear stress direction (across colonies) under dynamic tension. Fractography of recovered samples also shows consistent features.

36 MATERIALS SCIENCE↗

A scalable digital platform for the use of digital twins in additive manufacturing

We report that while Additive Manufacturing promises to reshape the manufacturing landscape, challenges related to part, and process qualification hinder its widespread adoption. The Instance-Qualified approach seeks to qualify individual parts, even for processes with high variability, by leveraging the concept of a digital twin. This work proposes a scalable cyberphysical infrastructure to enable the construction and use of such digital twins. This work also introduces the concept of an Augmented Intelligence Relay, which allows Artificial Intelligence algorithms to predict component performance for a given application even when it is impractical to perform a large number of physical tests.

36 MATERIALS SCIENCE↗

Attack Surface Analysis of the Digital Twins interface with Advanced Sensor and Instrumentation Interfaces: Cyber Threat Assessment and Attack Demonstration for Digital Twins in Advanced Reactor Architectures

A digital twin is a virtual representation of a physical system or object using real-time data that can predict and analyze how the system or object performs. This relatively new technology can be applied to the field of nuclear power generation, to aid in the design and development of new nuclear power plants and reduce operation costs using predictive maintenance and other data analytical methods. While there are already companies utilizing simulation software to train operators and technicians in the nuclear industry, some are now transitioning to utilizing their existing technology, software, and methods to develop digital twin solutions for the next generation of nuclear power plants, offering their services to utilities and government organizations around the world.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A four‐alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full‐field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet‐printed anthropomorphic phantom

Purpose The advent of three‐dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clinical trials are the gold standard for assessing image quality, phantom‐based studies can provide a simpler and less burdensome approach. In this work, a complete framework is presented for task‐based evaluation of microcalcification (MCs) detection performance for DBT imaging systems. Methods The framework consists of three parts. The first part is a realistic anthropomorphic physical breast phantom created through inkjet printing, with parchment paper and iodine‐doped ink. The second is a method for inserting realistic MCs fabricated from calcium hydroxyapatite. The reproducibility and stability of the phantom materials were investigated through multiple samples of parchment and ink over 6 months. The final part is an analysis using a four‐alternative forced choice (4AFC) reader study. To demonstrate the framework, a task‐based 4AFC study was conducted using a clinical system to compare performance from DBT, synthetic mammography (SM), and full‐field digital mammography (FFDM). Nine human observers read images containing MC clusters imaged with all three modalities and tried to correctly locate the MCs. The proportion correct (PC) was measured as the number of correctly detected clusters out of all trials. Results Overall, readers scored the highest with FFDM, (PC = 0.95 ± 0.03) then DBT (0.85 ± 0.04), and finally SM (0.44 ± 0.06). For the parchment and ink samples, the linear attenuation properties were very stable over 6 months. In addition, little difference was found between the various parchment and ink samples, indicating good reproducibility. Conclusions This framework presents a promising methodology for evaluating diagnostic task performance of clinical breast DBT systems.

Ikejimba, Lynda C.↗

Digital zero noise extrapolation for quantum error mitigation

Zero-noise extrapolation (ZNE) is an increasingly popular technique for mitigating errors in noisy quantum computations without using additional quantum resources. We review the fundamentals of ZNE and propose several improvements to noise scaling and extrapolation, the two key components in the technique. We introduce unitary folding and parameterized noise scaling. Furthermore, these are digital noise scaling frameworks, i.e. one can apply them using only gate-level access common to most quantum instruction sets. We also study different extrapolation methods, including a new adaptive protocol that uses a statistical inference framework. Benchmarks of our techniques show error reductions of 18X to 24X over non-mitigated circuits and demonstrate ZNE effectiveness at larger qubit numbers than have been tested previously. In addition to presenting new results, this work is a self-contained introduction to the practical use of ZNE by quantum programmers.

quantum computing↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sloan Digital Sky Survey IV: Mapping the Milky Way, Nearby Galaxies, and the Distant Universe

We describe the Sloan Digital Sky Survey IV (SDSS-IV), a project encompassing three major spectroscopic programs. The Apache Point Observatory Galactic Evolution Experiment 2 (APOGEE-2) is observing hundreds of thousands of Milky Way stars at high resolution and high signal-to-noise ratios in the near-infrared. The Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey is obtaining spatially resolved spectroscopy for thousands of nearby galaxies (median z∼0.03). The extended Baryon Oscillation Spectroscopic Survey (eBOSS) is mapping the galaxy, quasar, and neutral gas distributions between z∼0.6 and 3.5 to constrain cosmology using baryon acoustic oscillations, redshift space distortions, and the shape of the power spectrum. Within eBOSS, we are conducting two major subprograms: the SPectroscopic IDentification of eROSITA Sources (SPIDERS), investigating X-ray AGNs and galaxies in X-ray clusters, and the Time Domain Spectroscopic Survey (TDSS), obtaining spectra of variable sources. All programs use the 2.5 m Sloan Foundation Telescope at the Apache Point Observatory; observations there began in Summer 2014. APOGEE-2 also operates a second near-infrared spectrograph at the 2.5 m du Pont Telescope at Las Campanas Observatory, with observations beginning in early 2017. Observations at both facilities are scheduled to continue through 2020. In keeping with previous SDSS policy, SDSS-IV provides regularly scheduled public data releases; the first one, Data Release 13, was made available in 2016 July.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional displays for natural hazards analysis, using classified Landsat Thematic Mapper digital data and large-scale digital elevation models

Methods are described for using Landsat Thematic Mapper digital data and digital elevation models for the display of natural hazard sites in a mountainous region of northwestern Montana, USA. Hazard zones can be easily identified on the three-dimensional images. Proximity of facilities such as highways and building locations to hazard sites can also be easily displayed. A temporal sequence of Landsat TM (or similar) satellite data sets could also be used to display landscape changes associated with dynamic natural hazard processes.

Butler, David R.↗