Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Prototype hardware design and testing of the global common module for the global trigger subsystem of the ATLAS phase-II upgrade

We report the High-Luminosity Large Hadron Collider (HL-LHC) will deliver more than ten times the integrated luminosity of the previous runs combined. Meeting its stricter throughput requirements poses new challenges to the Trigger and Data Acquisition (TDAQ) systems of the LHC experiments. Introduced in the framework of the ATLAS experiment’s HL upgrade, the Global Trigger (GT) is a new subsystem which will perform offline-like algorithms on full-granularity calorimeter data. The implementation of the GT’s functionality is firmware-focused and is composed of three layers: multiplexing (or data aggregating), global event processing, and demultiplexing interface to the central trigger processor. Each layer will be composed of several, similar nodes, hosted on replicas of identical hardware, the Global Common Module (GCM), an ATCA front board which is designed to be adopted throughout the entire GT subsystem. This article proceeds from the TWEPP 2021 conference and presents the GCM hardware design, performed in 2020, and focuses on some key results of its extensive testing performed in 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗

Experimental results from the characterization of a 32-channels mixed-signal processor for the GAPS experiment

This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.

Riceputi, Elisa↗

A 32-channels readout ASIC for X-ray spectrometry and tracking in the GAPS experiment

Here this work describes the architecture and the experimental results from the characterization of a 32-channels mixed-signal Application-Specific Integrated Circuit (ASIC) developed for the readout of the lithium-drifted silicon, Si(Li), detectors of the General AntiParticle Spectrometer (GAPS) experiment dedicated to searching for dark matter. The instrument is designed for the identification of antiprotons, antideuterons and antihelium nuclei from cosmic rays during an Antarctic balloon mission scheduled for late 2024. A full custom integrated circuit, named SLIDER32 (32-channels Si-LI DEtector Readout) ASIC, has been produced in a commercial 180 nm CMOS technology. The ASIC is comprised of 32 low-noise analog readout channels featuring dynamic signal compression to comply with the wide input range, an 11-bit SAR ADC and a digital back-end section which is responsible for channel setting and for sending digital information to the data acquisition system (DAQ). The circuit design criteria and the experimental results are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantized Constant-Q Gabor Atoms for Sparse Binary Representations of Cyber-Physical Signatures

Increased data acquisition by uncalibrated, heterogeneous digital sensor systems such as smartphones present new challenges. Binary metrics are proposed for the quantification of cyber-physical signal characteristics and features, and a standardized constant-Q variation of the Gabor atom is developed for use with wavelet transforms. Two different continuous wavelet transform (CWT) reconstruction formulas are presented and tested under different signal to noise ratio (SNR) conditions. A sparse superposition of Nth order Gabor atoms worked well against a synthetic blast transient using the wavelet entropy and an entropy-like parametrization of the SNR as the CWT coefficient-weighting functions. The proposed methods should be well suited for sparse feature extraction and dictionary-based machine learning across multiple sensor modalities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The LSST Camera (LSSTCam)

The LSST Camera is the sole instrument for the NSF-DOE Vera C. Rubin Observatory and consists of a 3.2 gigapixel focal plane mosaic with in-vacuum controllers, dedicated guider and wavefront CCDs, a three-element corrector whose largest lens is 1.55m in diameter, six optical interference filters covering a 320-1050nm band pass with an out-of-plane filter exchange mechanism, and camera slow control and data acquisition systems capable of digitizing each image in 2 seconds.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Frequency Division Multiplexing and Neural Networks in the Operation and Diagnosis of the Stator Current and Shaft Position Sensors Used in Electric/Hybrid Vehicles

Fast, precise and robust sensing of currents and motor shaft angle is essential for the excellent performance of electric and hybrid vehicles (EV/HEV). Multiplexing techniques are commonly applied in data acquisition systems (DAQs) to digitize the signals sensed in EV/HEV drives. Frequency-division multiplexing (FDM) applied to get the signals from current sensors and resolver angular position sensor has advantages over conventional multiplexing approaches. However, problems such as aging and mechanical imperfections distort the outputs of those sensors, producing measurement errors of the angular position and currents. Conventional techniques designed to compensate for those errors cannot be applied in signals multiplexed in frequency. This paper proposes online techniques to detect and compensate for the distortions in the resolver sensor and current sensors. The demultiplexing process was adjusted to allow distortion detection and compensation. An auto-associative neural network (ANN) compensates for the current measurement error, while an energy-based technique is applied to compensate for the distortions in the resolver outputs. The obtained results show that the distortions were compensated, allowing a more accurate estimation of stator currents and angular position when FDM is applied in EV/HEV DAQs.

Pereira Pinto, Joao↗

TListSpectrum

TListSpectrum is a C++ class developed inside the CERN high-energy physics analysis C++ framework ROOT. This class structure was developed to assist in the processing, visualization, and analysis of list-mode or time-stamped radiation spectroscopy data. The class structure currently contains parsing and functionality to synthesize list-mode data from CAEN and Mirion Lynx radiation spectroscopy digital acquisition systems along with feature functionality to post-process data sets and build coincident data sets from the instrument.

Pierson, Bruce↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

Waveform processing using neural network algorithms on the front-end electronics

In a multi-channel radiation detector readout system, waveform sampling, digitization, and raw data transmission to the data acquisition system constitute a conventional processing chain. The deposited energy on the sensor is estimated by extracting peak amplitudes, area under pulse envelopes from the raw data, and starting times of signals or time of arrivals. However, such quantities can be estimated using machine learning algorithms on the front-end Application-Specific Integrated Circuits (ASICs), often termed as “edge computing”. Edge computation offers enormous benefits, especially when the analytical forms are not fully known or the registered waveform suffers from noise and imperfections of practical implementations. In this work, we aim to predict peak amplitude from a single waveform snippet whose rising and falling edges containing only 3 to 4 samples. We thoroughly studied two well-accepted neural network algorithms, Multi-Layer Perceptron (MLP) and Convolutional Neural Network (CNN) by varying their model sizes. Further, to better fit front-end electronics, neural network model reduction techniques, such as network pruning methods and variable-bit quantization approaches, were also studied. By combining pruning and quantization, our best performing model has the size of 1.5 KB, reduced from 16.6 KB of its full model counterpart. It can reach mean absolute error of 0.034 comparing to that of a naive baseline of 0.135. Such parameter-efficient and predictive neural network models established feasibility and practicality of their deployment on front-end ASICs.

47 OTHER INSTRUMENTATION↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times. A 1 st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.

monitoring↗

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Industry 4.0 and Intelligent Manufacturing Processes: A Review of Modern Sensing Technologies

Digital Manufacturing technologies have quickly become ubiquitous in the manufacturing industry. The transformation commonly referred to as the fourth industrial revolution, or Industry 4.0, has ushered in a wide range of communication technologies, connection mechanisms, and data analysis capabilities. These technologies provide powerful tools to create a more lean, profitable, and data-driven manufacturing processes. In this paper, we review modern communication technologies and connection architectures for Digital Manufacturing and Industry 4.0 applications. An introduction to Cyber-Physical Systems and a review of digital manufacturing trends is followed by an overview of data acquisition methods for manufacturing processes. Numerous communication protocols are presented and discussed for connecting disparate machines and processes. Flexible data architectures are discussed and examples of machine monitoring implementations are provided. Finally, select implementations of these communication protocols and architectures are surveyed with recommendations for future architecture implementations.

42 ENGINEERING↗