Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

Design of a low-emittance lattice for 3.5 GeV synchrotron light source

We investigate a lattice design for a low-emittance, high-brilliance intermediate energy synchrotron light source that is being intensively performed in the world. We present the design results in detail for a non-achromatic double bend achromat lattice with an emittance of 1.1 nm and 597.6 m circumference. Each superperiod has 4 straight sections, 7 m, 5.4 m, and 2 × 2.8 m in length, giving a total of 60 straight sections in the ring. The lattice is designed to be flexible and also provides an achromatic optics with an emittance of 3.2 nm. The lattice provides high brilliance at a photon energy of a few tens of keV, which meets the requirements of hard X-ray synchrotron radiation users. We investigated the dynamic aperture in the lattice with machine errors using a simulation method that achieves the optimal tune for the ring. The low-emittance lattice provides sufficient dynamic aperture after closed orbit distortion correction. We show an estimate of variations of emittance, energy spread, and dynamic aperture due to a wiggler in the straight sections. We present the design of an injection scheme for full energy injection, the space allocation in injection section, and the particle dynamics of injected beam. Particle tracking after beam injection was performed to examine the validity of the injection scheme. Our design lattice shows good optimization in terms of the emittance, number of straight sections, brilliance, and circumference as a light source for 3.5 GeV beam energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel scanning electron microscope bulge test technique integrated with loading function

Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these membranes poses a challenge over the conventional measurements at macro-scales. In this study, a novel bulge test method is presented for the evaluation of mechanical property of micro thin membranes. Three aspects are discussed in the study: (a) A novel bulge test with a Scanning Electron Microscope system realizing the function of loading and measuring simultaneously; (b) a simplified Digital Image Correlation method for a height measurement; and (c) an imaging distortion correction by the introduction of a scanning Moiré method. Combined with the above techniques, biaxial modulus as well as Young's modulus of the polyimide film can be determined. Besides, a standard tensile test is conducted as an auxiliary experiment to validate the feasibility of the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principles of stereo reconstruction of aerial objects using stationary cameras

An overview is given here of the principles and mathematics of stereo reconstruction of objects in the sky using stationary cameras with an emphasis on meteorological applications. Through its Atmospheric Radiation Measurement program, the Department of Energy has operated stereo-photogrammetric cameras since 2017 as part of an effort to measure the life-cycle properties of clouds. At the core of that technology is stereo reconstruction, which calculates the real-world position of an object from the location of the object’s image in two cameras’ photographs. Here, stereo reconstruction is stripped down to its basic elements and presented using conventions tailored to applications in atmospheric science. In addition, the resulting equations are used to illustrate the high sensitivity of reconstructed cloud positions to errors in the cameras’ Euler angles. The interested reader will find here a self-contained guide to performing stereo reconstructions using distortion-corrected images from a pair of calibrated, stationary cameras, as well as a demonstration of the need for high accuracy in the measurement of camera properties and orientations.

47 OTHER INSTRUMENTATION↗

THE PROPER MOTION OF PALOMAR 5

Palomar 5 (Pal 5) is a faint halo globular cluster associated with narrow tidal tails. It is a useful system to understand the process of tidal dissolution, as well as to constrain the potential of the Milky Way. A well-determined orbit for Pal 5 would enable detailed study of these open questions. We present here the first CCD-based proper motion measurement of Pal 5 obtained using SDSS as a first epoch and new Large Binocular Telescope/Large Binocular Camera (LBC) images as a second, giving a baseline of 15 years. We perform relative astrometry, using SDSS as a distortion-free reference, and images of the cluster and also of the Pal 5 stream for the derivation of the distortion correction for LBC. The reference frame is made up of background galaxies. We correct for differential chromatic refraction using relations obtained from SDSS colors as well as from flux-calibrated spectra, finding that the correction relations for stars and for galaxies are different. We obtain μ{sub α} = −2.296 ± 0.186 mas yr{sup −1} and μ{sub δ} = −2.257 ± 0.181 mas yr{sup −1} for the proper motion of Pal 5. We use this motion, and the publicly available code galpy, to model the disruption of Pal 5 in different Milky Way models consisting of a bulge, a disk, and a spherical dark matter halo. Our fits to the observed stream properties (streak and radial velocity gradient) result in a preference for a relatively large Pal 5 distance of around 24 kpc. A slightly larger absolute proper motion than what we measure also results in better matches but the best solutions need a change in distance. We find that a spherical Milky Way model, with V{sub 0} = 220 km s{sup −1} and V{sub 20} {sub kpc}, i.e., approximately at the apocenter of Pal 5, of 218 km s{sup −1}, can match the data well, at least for our choice of disk and bulge parametrization.

79 ASTRONOMY AND ASTROPHYSICS↗

RAVEN AND THE CENTER OF MAFFEI 1: MULTI-OBJECT ADAPTIVE OPTICS OBSERVATIONS OF THE CENTER OF A NEARBY ELLIPTICAL GALAXY AND THE DETECTION OF AN INTERMEDIATE AGE POPULATION

Near-infrared (NIR) spectra that have an angular resolution of ∼0.15 arcsec are used to examine the stellar content of the central regions of the nearby elliptical galaxy Maffei 1. The spectra were recorded at the Subaru Telescope, with wavefront distortions corrected by the RAVEN Multi-object Adaptive Optics science demonstrator. The Ballick–Ramsey C{sub 2} absorption bandhead near 1.76 μm is detected, and models in which ∼10%–20% of the light near 1.8 μm originates from stars of spectral type C5 reproduce the depth of this feature. Archival NIR and mid-infrared images are also used to probe the structural and photometric properties of the galaxy. Comparisons with models suggest that an intermediate age population dominates the spectral energy distribution between 1 and 5 μm near the galaxy center. This is consistent not only with the presence of C stars, but also with the large Hβ index that has been measured previously for Maffei 1. The J − K color is more or less constant within 15 arcsec of the galaxy center, suggesting that the brightest red stars are well-mixed in this area.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

We report in the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B 0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (λ ≈ 400–900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

synthetic diagnostic↗

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum control on entangled bipartite qubits

Ising interactions between qubits can produce distortion on entangled pairs generated for engineering purposes (e.g., for quantum computation or quantum cryptography). The presence of parasite magnetic fields destroys or alters the expected behavior for which it was intended. In addition, these pairs are generated with some dispersion in their original configuration, so their discrimination is necessary for applications. Nevertheless, discrimination should be made after Ising distortion. Quantum control helps in both problems; making some projective measurements upon the pair to decide the original state to replace it, or just trying to reconstruct it using some procedures which do not alter their quantum nature. Results about the performance of these procedures are reported. First, we will work with pure systems studying restrictions and advantages. Then, we will extend these operations for mixed states generated with uncertainty in the time of distortion, correcting them by assuming the control prescriptions for the most probable one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anniversary Paper: Image processing and manipulation through the pages of Medical Physics

The language of radiology has gradually evolved from ''the film'' (the foundation of radiology since Wilhelm Roentgen's 1895 discovery of x-rays) to ''the image,'' an electronic manifestation of a radiologic examination that exists within the bits and bytes of a computer. Rather than simply storing and displaying radiologic images in a static manner, the computational power of the computer may be used to enhance a radiologist's ability to visually extract information from the image through image processing and image manipulation algorithms. Image processing tools provide a broad spectrum of opportunities for image enhancement. Gray-level manipulations such as histogram equalization, spatial alterations such as geometric distortion correction, preprocessing operations such as edge enhancement, and enhanced radiography techniques such as temporal subtraction provide powerful methods to improve the diagnostic quality of an image or to enhance structures of interest within an image. Furthermore, these image processing algorithms provide the building blocks of more advanced computer vision methods. The prominent role of medical physicists and the AAPM in the advancement of medical image processing methods, and in the establishment of the ''image'' as the fundamental entity in radiology and radiation oncology, has been captured in 35 volumes of Medical Physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

In the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (~400-900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE [Landreman et al 2014 Comput. Phys. Commun. 185 847-855] is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT [Hoppe et al 2018 Nucl. Fusion 58 026032] to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peregrine

The purpose of “Peregrine” is to perform in-situ quality control of the additive manufacturing process in powder bed systems. The software is an AI-based method to automatically detect and map multiple classes of defects present in the top layer of a powder bed system, either after material deposition, i.e. raking, or after printing the layer. Relying on image data or sensing modalities that can be converted into image data, the code allows for: (1) various steps of pre-processing of the data (registration, distortion correction, etc), (2) annotation of training datasets, (3) processing of data inline or offline, (4) creating 3D rendering of the defect map, and (5) implementation of corrective actions if allowed by the manufacturing platform.

Paquit, Vincent C↗

System, apparatus, and method for determining elemental composition using 4D STEM

The present disclosure relates to transmission electron microscopy for evaluation of biological matter. According to an embodiment, the present disclosure further relates to an apparatus for determining the structure and/or elemental composition of a sample using 4D STEM, comprising a direct bombardment detector operating with global shutter readout, processing circuitry configured to acquire images of bright-field disks using either a contiguous array or non-contiguous array of detector pixel elements, correct distortions in the images, align each image of the images based on a centroid of the bright-field disk, calculate a radial profile of the images, normalize the radial profiles by a scaling factor, calculate the rotationally-averaged edge profile of the bright-field disk, and determine elemental composition within the specimen based on the characteristics of the edge profile of the bright-field disk corresponding to each specimen location.

Bammes, Benjamin↗

Computer correction of an image distorted by turbulent atmosphere

The method for computer correction of images distorted by turbulent atmosphere is realised by means of the simplest optical system comprising a telescope and digital TV-camera. Real-time images with the diffraction resolution are obtained at ground paths of length up to 1800 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tidally distorted exoplanets: Density corrections for short-period hot-Jupiters based solely on observable parameters

The close proximity of short-period hot-Jupiters to their parent star means they are subject to extreme tidal forces. This has a profound effect on their structure and, as a result, density measurements that assume that the planet is spherical can be incorrect. We have simulated the tidally distorted surface for 34 known short-period hot-Jupiters, assuming surfaces of constant gravitational equipotential for the planet, and the resulting densities have been calculated based only on observed parameters of the exoplanet systems. Comparing these results to the density values, assuming the planets are spherical, shows that there is an appreciable change in the measured density for planets with very short periods (typically less than two days). For one of the shortest-period systems, WASP-19b, we determine a decrease in bulk density of 12% from the spherical case and, for the majority of systems in this study, this value is in the range of 1%-5%. On the other hand, we also find cases where the distortion is negligible (relative to the measurement errors on the planetary parameters) even in the cases of some very short period systems, depending on the mass ratio and planetary radius. For high-density gas planets requiring apparently anomalously large core masses, density corrections due to tidal deformation could become important for the shortest-period systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Anti-distortion bioinspired camera with an inhomogeneous photo-pixel array

The bioinspired camera, comprising a single lens and a curved image sensor—a photodiode array on a curved surface—, was born of flexible electronics. Its economical build lends itself well to space-constrained machine vision applications. The curved sensor, much akin to the retina, helps image focusing, but the curvature also creates a problem of image distortion, which can undermine machine vision tasks such as object recognition. Here we report an anti-distortion single-lens camera, where 4096 silicon photodiodes arrayed on a curved surface in a nonuniform pattern assimilated to the distorting optics are the key to anti-distortion engineering. That is, the photo-pixel distribution pattern itself is warped in the same manner as images are warped, which correctively reverses distortion. Acquired images feature no appreciable distortion across a 120° horizontal view, as confirmed by their neural-network recognition accuracies. This distortion correction via photo-pixel array reconfiguration is a form of in-sensor computing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved measurement method for electron energy distribution functions with high accuracy and reliability

An improved ac superimposed method for measuring the electron energy distribution function (EEDF) with high accuracy is proposed. Although high amplitude of the superimposed ac voltage provides a higher signal-to-noise ratio (SNR), it causes the distortion in the EEDF. To correct the distortion, we used two different EEDFs measured by applying two different amplitudes. The distortion was accurately corrected over the entire electron energy region, and the corrected EEDF had the better SNR. The reliability of the corrected EEDF was proved by comparing the effective electron temperatures obtained from the measured EEDFs, and as a result, the corrected EEDF was very reliable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗