Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage combined with INL Thermal Energy Distribution System
This is the PPT slides for ANS conference. So, there is no abstract.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This is the PPT slides for ANS conference. So, there is no abstract.
The use of hydrogen as a fuel is increasing exponentially, and the most economical way to store and transport hydrogen for fuel use is as a high-pressure gas. Polymers are widely used for hydrogen distribution and storage systems because they are chemically inert towards hydrogen. However, when exposed to high-pressure hydrogen, some hydrogen diffuses through polymers and occupies the preexisting cavities inside the material. Upon depressurization, the hydrogen trapped inside polymer cavities can cause blistering or cracking by expanding these cavities. A continuum mechanics--based deformation model was deployed to predict the stress distribution and damage propagation while the polymer undergoes depressurization after high-pressure hydrogen exposure. The effects of cavity size, cavity location, and pressure inside the cavity on damage initiation and evolution inside the polymer were studied. The stress and damage evolution in the presence of multiple cavities was also studied, because interaction among cavities alters the damage and stress field. It was found that all these factors significantly change the stress state in the polymer, resulting in different paths for damage propagation. The effect of adding carbon black filler particles and plasticizer on the damage was also studied. It was found that damage tolerance of the polymer increases drastically with the addition of carbon black fillers, but decreases with the addition of the plasticizer.
The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.
The presence of hazardous air pollutants (HAPs) entrained in end-use natural gas (NG) is an understudied source of human health risks. We performed trace gas analyses on 185 unburned NG samples collected from 159 unique residential NG stoves across seven geographic regions in California. Our analyses commonly detected 12 HAPs with significant variability across region and gas utility. Mean regional benzene, toluene, ethylbenzene, and total xylenes (BTEX) concentrations in end-use NG ranged from 1.6–25 ppmv–benzene alone was detected in 99% of samples, and mean concentrations ranged from 0.7–12 ppmv (max: 66 ppmv). By applying previously reported NG and methane emission rates throughout California’s transmission, storage, and distribution systems, we estimated statewide benzene emissions of 4,200 (95% CI: 1,800–9,700) kg yr –1 that are currently not included in any statewide inventories–equal to the annual benzene emissions from nearly 60,000 light-duty gasoline vehicles. Additionally, we found that NG leakage from stoves and ovens while not in use can result in indoor benzene concentrations that can exceed the California Office of Environmental Health Hazard Assessment 8-h Reference Exposure Level of 0.94 ppbv–benzene concentrations comparable to environmental tobacco smoke. This study supports the need to further improve our understanding of leaked downstream NG as a source of health risk.
BULKI-Store is a distributed object storage system optimized for high-performance computing environments. Built with a Rust core and Python bindings, it efficiently manages scientific and machine learning datasets across HPC clusters. The system employs a client-server architecture with MPI integration, enabling seamless scaling on supercomputers like Perlmutter. BULKI-Store's object-oriented approach provides intuitive data organization with rich metadata support, contrasting with traditional file-based solutions. Key optimizations include selective checkpoint loading, unified checkpoint files, and object chunking for large data transfers. For machine learning workloads, BULKI-Store offers advantages through fine-grained access patterns, dynamic data sharing between training instances, and reduced memory pressure. Memory management features include strategic Python GC calls, minimized data copies, and batch processing capabilities. The system leverages Rayon's thread pool for asynchronous data prefetching and supports multiple CPU architectures (ARM64, x86, AMD, RISC-V). By combining performance optimizations with developer-friendly APIs, BULKI-Store addresses the complex data management challenges of modern HPC applications while maintaining compatibility across heterogeneous computing environments.
Technologies that enable direct-air-capture (DAC) of CO2 and eliminate the need for a CO2 capture, storage, and distribution system would significantly reduce the cost of algal production, and greatly increase the volume of algae biomass that can be produced by enabling algae farms to be located anywhere. Such technologies include cultivation under high alkalinity/high pH conditions, which increase the driving force for CO2 absorption, and development of genetic tools and genetically engineered strains to decorate the surface of the algae with carbonic anhydrase (CA), enable secretion of CA by the algae, or more generally boost the performance of the carbon concentrating mechanism (CCM).
The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.
Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.
This guide was created to empower Energy Storage for Social Equity (ES4SE) community members to learn more about power systems, energy distribution, renewable energy, and battery storage systems. It was developed in an accessible format for audiences of varied backgrounds and requires no previous experience in energy storage. It is intended to serve readers as both an educational and reference document as they consider, procure, and deploy power systems that include battery energy storage technologies and microgrids in their communities. By providing an introductory overview of the basics of electricity, power generation, and household energy consumption and loads, this guide prepares readers to learn even more about battery energy storage, microgrid systems, and the sizing of solar and battery systems.
The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.
Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.
The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.
The purpose of this paper is to qualitatively explore the question of whether as a power system’s sources and energy storage become more distributed, the power system also tends to become more resilient. The paper is divided into two main parts. After presenting introductory material, Part 1 looks at factors that might limit the ability of ‘fully-distributed’ resources to provide the expected resilience, and Part 2 considers factors that might make a more centralized system more resilient.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.
Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.