Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Slitless Solar Spectroscopy

Spectrographs have traditionally suffered from the inability to obtain line intensities, widths, and Doppler shifts over large spatial regions of the Sun quickly because of the narrow instantaneous field of view. This has limited the spectroscopic analysis of rapidly varying solar features like, flares, CME eruptions, coronal jets, and reconnection regions. Imagers have provided high time resolution images of the full Sun with limited spectral resolution. In this paper we present recent advances in deconvolving spectrally dispersed images obtained through broad slits. We use this new theoretical formulation to examine the effectiveness of various potential observing scenarios, spatial and spectral resolutions, signal to noise ratio, and other instrument characteristics. This information will lay the foundation for a new generation of spectral imagers optimized for slitless spectral operation, while retaining the ability to obtain spectral information in transient solar events.

Davila, Joseph M.↗

Slitless Spectroscopy

Spectrographs have traditionally suffered from the inability to obtain line intensities, widths, and Doppler shifts over large spatial regions of the Sun quickly because of the narrow instantaneous field of view. This has limited the spectroscopic analysis of rapidly varying solar features like, flares, CME eruptions, coronal jets, and reconnection regions. Imagers have provided high time resolution images of the full Sun with limited spectral resolution. In this paper we present recent advances in deconvolving spectrally dispersed images obtained through broad slits. We use this new theoretical fomulation to examine the effectiveness of various potential observing scenarios, spatial and spectral resolutions, signal to noise ratio, and other instrument characteristics. This information will lay the foundation for a new generation of spectral imagers optimized for slitless spectral operation, while retaining the ability to obtain spectral information in transient solar events.

Davila, Joseph M.↗

Mid-infrared solid-state lasers and laser materials

An account is given of NASA-Langley's objectives for the development of advanced lasers and laser materials systems applicable to remote sensing in the mid-IR range. Prominent among current concerns are fiber-optic spectroscopy, eye-safe solid-state lasers for both Doppler sensing and mid-IR wavelength-generation laser pumping, and nonlinear optics generating tunable mid-IR radiation. Ho:YAG lasers are noted to exhibit intrinsic advantages for the desired applications, and are pumpable by GaAlAs laser diodes with a quantum efficiency approaching 2.

Barnes, Norman P.↗

Infrared heterodyne spectroscopy in astronomy

A heterodyne spectrometer was constructed and applied to problems in infrared astronomical spectroscopy. The instrument offers distinct observational advantages for the detection and analysis of individual spectral lines at Doppler-limited resolution. Observations of carbon dioxide in planetary atmospheres and ammonia in circumstellar environments demonstrate the substantial role that infrared heterodyne techniques will play in the astronomical spectroscopy of the future.

Betz, A.↗

Laser heterodyne spectroscopy

High-resolution heterodyne spectroscopic studies of the atmosphere of Venus are surveyed with attention to Doppler shifts in the 10-micron CO2 lines. While the C-12(O-16)2 emission lines formed in the mesosphere near 115 km indicate that the winds are distinctly subsolar to antisolar, C-13(O-16)2 absorption lines for the stratosphere at about 75 km confirm that the pattern is a strong retrograde rotation with an average equatorial velocity of 90 plus or minus 7 m/sec. It is concluded that the winds change from retrograde to subsolar-to-antipolar between 80 and 115 km.

Betz, A. L.↗

High-Temperature Optical Window Design

A high-temperature optical window is essential to the optical diagnostics of high-temperature combustion rigs. Laser Doppler velocimetry, schlieren photography, light sheet visualization, and laser-induced fluorescence spectroscopy are a few of the tests that require optically clear access to the combustor flow stream. A design was developed for a high-temperature window that could withstand the severe environment of the NASA Lewis 3200 F Lean Premixed Prevaporized (LPP) Flame Tube Test Rig. The development of this design was both time consuming and costly. This report documents the design process and the lessons learned, in an effort to reduce the cost of developing future designs for high-temperature optical windows.

Roeloffs, Norman↗

Novel Optical Technique Developed and Tested for Measuring Two-Point Velocity Correlations in Turbulent Flows

A novel technique for characterizing turbulent flows was developed and tested at the NASA Glenn Research Center. The work is being done in collaboration with the University of Pittsburgh, through a grant from the NASA Microgravity Fluid Physics Program. The technique we are using, Homodyne Correlation Spectroscopy (HCS), is a laser-light-scattering technique that measures the Doppler frequency shift of light scattered from microscopic particles in the fluid flow. Whereas Laser Doppler Velocimetry gives a local (single-point) measurement of the fluid velocity, the HCS technique measures correlations between fluid velocities at two separate points in the flow at the same instant of time. Velocity correlations in the flow field are of fundamental interest to turbulence researchers and are of practical importance in many engineering applications, such as aeronautics.

Zimmerli, Gregory A.↗

The Polstar High Resolution Spectropolarimetry MIDEX Mission

The Polstar mission will provide a space-borne 60 cm spectropolarimeter operating at ultraviolet (UV) wavelengths, capturing all four Stokes parameters (intensity, two linear polarization components, and circular polarization). Polstar’s capabilities are designed to meet its goal of determining how circumstellar gas flows alter and inform massive star evolution, affect the stellar remnant population, and stir and enrich the interstellar medium (ISM). These will be achieved by investigating the dynamical geometries in the winds and disks of hot stars, the composition and magnetic alignment of interstellar dust, and the star-forming accretion disks of UV-bright stars at an important transition boundary. Together these areas map out a kind of two-way interface between massive stars and their effect on our galaxy, wherein the stellar winds enrich the ISM with metals and kinetic energy, preconditioning their environment and the stellar endpoints prior to undergoing supernova. The ISM dust in turn reveals the composition and magnetic environment leading to new star formation, and the accretion disks of Herbig Ae/Be stars reveal how the ISM gas returns to make new massive stars. Polstar will combine high-resolution spectroscopy in the time domain with high-precision UV polarimetry. Doppler-shifted UV resonance line opacity will provide information about circumstellar kinematics, while polarization gives complementary geometric information about unseen structures. The composition and magnetic alignment of the smallest interstellar dust grains provides a probe of the ISM utilizing radiative alignment theory (RAT). Polstar will operate in the far-UV (FUV) at 122–200 nm at high spectral resolution of around R ∼ 30k, and at FUV and near-UV (NUV) wavelengths of 122–320 nm at lower spectral resolutions of 0.1 - 1k. Detection of polarization levels as weak as 0.1% are expected, with a temporal cadence ranging from 5–10 minutes for most wind variability studies, to hours or days for sampling rotation, to days or weeks for sampling binary orbits, to months to a year for sampling substructure in the inner regions of protoplanetary disks. Sub-meter-class aperture is well suited to access this wide array of time domain science, made possible by restricting to a few hundred bright, massive stars, necessarily extincted by a small to moderate column of interstellar dust, informing both the attributes of the stars and the ISM through which they are seen. As such, the focus is on our own galaxy and its evolutionary drivers, but a few targets in the Magellanic clouds offer the potential to extend this understanding to low-metallicity environments.

Paul A Scowen↗

Discovery of the double Doppler-shifted emission-line systems in the X-ray spectrum of SS 433

We have used the CCD X-ray spectrometers on ASCA and resolved the X-ray emission line from the jet of SS 433 both into Doppler-shifted components with two distinct velocities, and into emission from different ionization states of iron, i.e., Fe XXV and Fe XXVI. This is the first direct detection of the two Doppler shifted beams in the X-ray spectra of SS 433 and allows the radial velocity of the jet along the line of sight to be determined with an accuracy comparable to the optical spectroscopy. We also found pairs of emission lines from other atomic species, such as ionized silicon and sulfur, with the Doppler shifts consistent with each other. This confirms the origin of the X-ray emission in the high temperature plasma in the jets.

Kotani, Taro↗

Ion and electron temperatures in the SUMMA mirror device by emission spectroscopy

Ion and electron temperatures, and ion drift were measured in a superconducting magnetic mirror apparatus by observing the Doppler-broadened charge-exchange component of the 667.8 and 587.6 nanometer He lines in He plasma, and the H sub alpha and H sub beta lines in H2 plasma. The second moment of the line profiles was used as the parameter for determining ion temperature. Corrections for magnetic splitting, fine structure, monochromator slit function, and variation in charge-exchange cross section with energy are included. Electron temperatures were measured by the line ratio method for the corona model, and correlations of ion and electron temperatures with plasma parameters are presented.

Patch, R. W.↗

Rotationally resolved collisional transfer rates in OH

Fluorescence lidar measurements of the hydroxyl radical require detailed information concerning collision induced processes in order to deduce the radical number density from a lidar return. The Goddard SFC OH lidar currently utilizes a broadband detector which precludes the necessity of fully understanding collisional redistribution of rotational energy within the excited state. Numerous advantages result however from the inclusion of a detector with a bandpass only slightly larger that the Doppler width of a rotational line. This however places more stringent requirements on the spectroscopy. Measurements were accordingly made of rotationally resolved quenching rates for collisions with O2, N2, and H2O. Rotational transfer rates were also measured for the same colliders. Quenching rates were measured using a Nd-YAG pumped Rh6G dye laser doubled into the UV. The OH lifetimes were measured as a function of pressure of quenching gas at total pressures of between 50 and 250 microns. Rotational transfer rates were measured by recording the emission spectrum on an intensified diode array and integrating over 10.000 laser shots.

Mcgee, T. J.↗

Effects of forearm bier block with bretylium on the hemodynamic and metabolic responses to handgrip

We tested the hypothesis that a reduction in sympathetic tone to exercising forearm muscle would increase blood flow, reduce muscle acidosis, and attenuate reflex responses. Subjects performed a progressive, four-stage rhythmic handgrip protocol before and after forearm bier block with bretylium as forearm blood flow (Doppler) and metabolic (venous effluent metabolite concentration and (31)P-NMR indexes) and autonomic reflex responses (heart rate, blood pressure, and sympathetic nerve traffic) were measured. Bretylium inhibits the release of norepinephrine at the neurovascular junction. Bier block increased blood flow as well as oxygen consumption in the exercising forearm (P < 0.03 and P < 0.02, respectively). However, despite this increase in flow, venous K(+) release and H(+) release were both increased during exercise (P < 0.002 for both indexes). Additionally, minimal muscle pH measured during the first minute of recovery with NMR was lower after bier block (6.41 +/- 0.08 vs. 6.20 +/- 0.06; P < 0.036, simple effects). Meanwhile, reflex effects were unaffected by the bretylium bier block. The results support the conclusion that sympathetic stimulation to muscle during exercise not only limits muscle blood flow but also appears to limit anaerobiosis and H(+) release, presumably through a preferential recruitment of oxidative fibers.

Non-NASA Center↗

Intrinsic Lyman Alpha Profiles of High-Velocity G, K, and M Dwarfs

Observations of H I Lyman alpha, the brightest UV emission line of late-type stars, are critical for understanding stellar chromospheres and transition regions, modeling photochemistry in exoplanet atmospheres, and measuring the abundances of neutral hydrogen and deuterium in the interstellar medium. Yet, Lyman alpha observations are notoriously challenging due to severe attenuation from interstellar gas, hindering our understanding of this important emission line's basic morphology. We present high-resolution far- and near-UV spectroscopy of five G, K, and M dwarfs with radial velocities large enough to Doppler shift the stellar Lyman alpha emission line away from much of the interstellar attenuation, allowing the line core to be directly observed. We detect self-reversal in the Lyman alpha emission line core for all targets, and we show that the self-reversal depth decreases with increasing surface gravity. Mg II self-reversed emission line profiles provide some useful information to constrain the Lyman alpha line core, but the differences are significant enough that Mg II cannot be used directly as an intrinsic Lyman alpha template during reconstructions. We show that reconstructions that neglect self-reversal could overestimate intrinsic Lyman alpha fluxes by 60-100% for G and K dwarfs and 40-170% for M dwarfs.

Allison Ann Youngblood↗

Tm,Ho:YAG laser with tunable range of 2.08-2.12 microns and its applications to spectroscopy

In recent advanced lasers, 2 micron solid-state lasers such as Tm:YAG and Ho:YAG lasers are very attractive for laser radar remote sensing technologies because of eye safety, realizations of all solid-state laser pumped by diode laser and smaller dimension, tunability of lasing wavelength, possibility of coherent detection, etc. Featuring these advantages, 2 micron lasers have been candidated as laser transmitters for use in water vapor Differential Absorption Lidar (DIAL), laser altimeter, Doppler wind sensor, Mie lidar, etc. Characterization of a tunable Cr, Tm, Ho:YAG laser and its applications to spectroscopy concerning absorption and reflectance are reported.

Asai, Kazuhiro↗

UV Spectroscopy of Star-Grazing Comets Within the 49 Ceti Debris Disk

We present the analysis of time-variable Doppler-shifted absorption features in far-UV spectra of the unusual 49 Ceti debris disk. This nearly edge-on disk is one of the brightest known and is one of the very few containing detectable amounts of circumstellar (CS) gas as well as dust. In our two visits of Hubble Space Telescope STIS spectra, variable absorption features are seen on the wings of lines arising from CII and CIV but not for any of the other CS absorption lines. Similar variable features have long been seen in spectra of the well-studied Beta Pictoris debris disk and attributed to the transits of star-grazing comets. We calculated the velocity ranges and apparent column densities of the 49 Cet variable gas, which appears to have been moving at velocities of tens to hundreds of kms(-1) relative to the central star. The velocities in the redshifted variable event seen in the second visit show that the maximum distances of the in falling gas at the time of transit were about 0.050.2 au from the central star. A preliminary attempt at a composition analysis of the redshifted event suggests that the C/O ratio in the in falling gas is super-solar, as it is in the bulk of the stable disk gas.

far-UV spectra↗

Use of PZT's for adaptive control of Fabry-Perot etalon plate figure

A Fabry Perot etalon, consisting of two spaced and reflective glass flats, provides the mechanism by which high resolution spectroscopy may be performed over narrow spectral regions. Space based applications include direct measurements of Doppler shifts of airglow absorption and emission features and the Doppler broadening of spectral lines. The technique requires a high degree of parallelism between the two flats to be maintained through harsh launch conditions. Monitoring and adjusting the plate figure by illuminating the Fabry Perot interferometer with a suitable monochromatic source may be performed on orbit to actively control of the parallelism of the flats. This report describes the use of such a technique in a laboratory environment applied to a piezo-electric stack attached to the center of a Fabry Perot etalon.

Skinner, WIlbert↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗