Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TEM Characterization of Nanostructured Grade 91 Neutron Irradiated to 6 DPA at 300 °C and 500 °C

Previously, samples of coarse grained (CG, grain diameter > 1 µm), ultra-fine grained (UFG, 1 µm> grain diameter> 100 nm), and nanocrystalline (NC, 100 nm> grain diameter) grade 91 steel were neutron irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Grade 91 is a ferritic/martensitic steel alloy with a nominal composition of Fe-9%Cr-1%Mo by weight, and it is being studied for applications in advanced nuclear reactor designs including as a fuel cladding material in gas cooled reactors. To assess the viability of this alloy for nuclear applications, the role of grain boundary size has not been sufficiently explored as a mechanism for developing radiation-tolerant materials. To achieve an UFG microstructure the material was processed using equal channel angular pressing (ECAP), and the NC microstructure was achieved through high pressure torsion (HPT). Such samples of various geometries for different types of characterization were irradiated to a dose of 6 displacements per atom (DPA) at separate temperature conditions of 300 °C and 500 °C. Thus, there were a total of 6 experimental conditions, three grain sizes (CG, UFG, and NC), each irradiated at two different temperature conditions (300 °C and 500 °C).

36 - MATERIALS SCIENCE↗

A Systematic Assessment of US Food and Drug Administration Dosing Recommendations For Drug Development Programs Amenable to Response‐Guided Titration

A key goal in drug development is optimized dosing for patients. Interactions between drug developers and regulatory scientists throughout development are important for the optimization of dosing and serve as a forum to discuss approaches for optimal dosing, such as precision or individualized dosing. To date, there has not been a systematic assessment of the advice provided by the US Food and Drug Administration (FDA) to drug developers from an individualized dosing perspective. Here, we reviewed FDA recommendations on dose selection for efficacy trials at end‐of‐phase meetings between the FDA and drug developers for 76 new molecular entities approved between 2013 and 2017 that are considered amenable for an individualized dosing method, response‐guided titration. Forty FDA dosing recommendations were identified as specific to dose selection and design of the respective efficacy trials and subsequently: (i) characterized based on if they were supportive of individualized dosing and (ii) compared with dosing regimens used in efficacy trials and labeling at approval to evaluate if FDA recommendations were implemented. Of these 40 recommendations for efficacy trials, 35 (88%) were considered supportive of individualized dosing. Eighteen of these 40 recommendations (45%) were incorporated into efficacy trials and 11 (28%) were incorporated into labeling. This research suggests that early FDA‐sponsor interactions can support the study of doses in efficacy trials that may lead to individualized dosing strategies in labeling.

Wang, Lingshan↗

Electron-Beam-Related Studies of Halide Perovskites: Challenges and Opportunities

Electron beam microscopy and related characterization techniques play an important role in revealing the microstructural, morphological, physical, and chemical information of halide perovskites and their impact on associated optoelectronic devices. However, electron beam irradiation usually causes damage to these beam-sensitive materials, negatively impacting their device performance, and complicating this interpretation. Here, the electron microscopy and spectroscopy techniques are reviewed that are crucial for the understanding of the crystallization and microstructure of halide perovskites. In addition, special attention is paid to assessing and mitigating the electron beam-induced damage caused by these techniques. Since the halide perovskites are fragile, a protocol involving delicate control of both electron beam dose and dose rate, coupled with careful data analysis, is key to enable the acquisition of reliable structural and compositional information such as atomic-resolution images, chemical elemental mapping and electron diffraction patterns. Limiting the electron beam dose is critical parameter enabling the characterization of various halide perovskites. Novel methods to unveil the mechanisms of device operation, including charge carrier generation, diffusion, and extraction are presented in scanning electron microscopy studies combined with electron-beam-induced current and cathodoluminescence mapping. Future opportunities for electron-beam-related characterizations of halide perovskites are also discussed.

36 MATERIALS SCIENCE↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Mean Heart Dose Is an Inadequate Surrogate for Left Anterior Descending Coronary Artery Dose and the Risk of Major Adverse Cardiac Events in Lung Cancer Radiation Therapy

Mean heart dose (MHD) over 10 Gy and left anterior descending (LAD) coronary artery volume (V) receiving 15 Gy (V15Gy) greater than 10% can significantly increase the risk of major adverse cardiac events (MACE) in patients with non-small cell lung cancer (NSCLC). We sought to characterize the discordance between MHD and LAD dose and the association of this classification on the risk of MACE after radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of FISH based G2-PCC assay for the cytogenetic assessment of high radiation dose exposures: Potential implications for rapid triage biodosimetry

The main goal of this study is to test the utility of calyculin A induced G2-PCC assay as a biodosimetry triage tool for assessing a wide range of low and acute high radiation dose exposures of photons. Towards this initiative, chromosome aberrations induced by low and high doses of x-rays were evaluated and characterized in G2-prematurely condensed chromosomes (G2-PCCs) by fluorescence in situ hybridization (FISH) using human centromere and telomere specific PNA (peptide nucleic acid) probes. A dose dependent increase in the frequency of dicentric chromosomes was observed in the G2-PCCs up to 20 Gy of x-rays. The combined yields of dicentrics and rings in the G2-PCCs showed a clear dose dependency up to 20 Gy from 0.02/cell for 0.1 Gy to 14.98/cell for 20 Gy. Centric rings were observed more frequently than acentric ring chromosomes in the G2-PCCs at all the radiation doses from 1 Gy to 20 Gy. A head-to-head comparison was also performed by FISH on the yields of chromosome aberrations induced by different doses of x-rays (0 Gy -7.5 Gy) in colcemid arrested metaphase chromosomes and calyculin A induced G2-PCCs. In general, the frequencies of dicentrics, rings and acentric fragments were slightly higher in G2-PCCs than in colcemid arrested metaphase chromosomes at all the radiation doses, but the differences were not statistically significant. To reduce the turnaround time for absorbed radiation dose estimation, attempt was made to obtain G2-PCCs by reducing the culture time to 36 hrs. The absorbed doses estimated in x-rays irradiated (0,1,2 and 4 Gy) G2-PCCs after 36 hrs of culture were grossly like that of G2-PCCs and colcemid arrested metaphase chromosomes prepared after 48 hrs of culture. Our study indicates that the shortened version of calyculin A induced G2-PCC assay coupled with the FISH staining technique can serve as an effective triage biodosimetry tool for large-scale radiological/nuclear incidents.

Science & Technology - Other Topics↗

A Study on Radionuclides Selection for DCGLs Development for Site Release of KRR Units 1 and 2 site in Korea - 20256

The selection of Derived Concentration Guideline Levels (DCGLs) in nuclear facilities decommissioning is important because they serve as criteria for site characterization and final status surveys. DCGLs should be derived for KAERI TRIGA Mark II and III research reactor site clearance and prior to the work, a radionuclides list for DCGLs consideration was created. Radionuclides selection for DCGLs was performed according to the procedure proposed by the US NRC based on the characterization survey related to the decommission site. By evaluating the dose contribution of each radionuclide using D and D computer code, radionuclides with a dose contribution fraction of 0.1% or more for the entire radionuclide were selected. As a result, the selected radionuclides were beta radionuclides H-3, C-14 and Sr-90 and gamma radionuclides Co-60, Cs-137, Eu-152 and Eu-154. The selected radionuclides can be presented for consultation with domestic regulatory agencies in the future and will be used as the technical base of DCGLs for the final status survey. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Nanoscale friction of CVD single-layer MoS 2 with controlled defect formation

Two-dimensional (2D) layered nanomaterials such as graphene, molybdenum disulfide (MoS 2 ), or tungsten disulfide offer a promising solution in areas of solid-state lubrication, due to their excellent mechanical properties as well as low friction. However, defects can influence their friction and reduce their superior tribological properties. Thus, it is crucial to understand the effects of defects on sliding behavior in 2D nanomaterials, to foster a functional strategy for utilizing 2D nanomaterials as solid-state tribological films. In this study, frictional effects of defects, grain boundaries, and atomic-scale structural defects were explored on chemical vapor deposition (CVD) grown single layer MoS 2 . Selective patterning of defects into MoS 2 was accomplished via controlled irradiation of helium ions with varying ion doses. The friction of MoS 2 was characterized by friction force microscopy (FFM) and was found that friction depends on the defect formation controlled by helium ion irradiation. This approach offers a correlation between surface topography, defects and friction. Understanding the relative friction of MoS 2 in the presence of different levels of defects is foundational to studying tribological properties of a single layer MoS 2 at both nanoscales and macroscales.

36 MATERIALS SCIENCE↗

Photoinitiated Olefin Metathesis and Stereolithographic Printing of Polydicyclopentadiene

Recent progress in photoinitiated ring-opening metathesis polymerization (photoROMP) has enabled the lithographic production of patterned films from olefinic resins. Recently, we reported the use of a latent ruthenium catalyst (HeatMet) in combination with a photosensitizer (2-isopropylthioxanthone) to rapidly photopolymerize dicyclopentadiene (DCPD) formulations upon irradiation with UV light. While this prior work was limited in terms of catalyst and photosensitizer scope, a variety of alternative catalysts and photosensitizers are commercially available that could allow for tuning of thermomechanical properties, potlifes, activation rates, and irradiation wavelengths. Herein, 14 catalysts and 8 photosensitizers are surveyed for the photoROMP of DCPD and the structure–activity relationships of the catalysts examined. Properties relevant to stereolithography additive manufacturing (SLA AM)-potlife, irradiation dose required to gel, conversion-are characterized to develop catalyst and photosensitizer libraries to inform development of SLA AM resin systems. Two optimized catalyst/photosensitizer systems are demonstrated in the rapid SLA printing of complex, multidimensional pDCPD structures with microscale features under ambient conditions.

36 MATERIALS SCIENCE↗

Examining the effects of soil entrainment during nuclear cloud rise on fallout predictions using a multiscale atmospheric modeling framework

Current operational models for nuclear cloud rise over land were developed and validated using observations from shallow-buried or surface detonations, where lofted soil quickly mixed with fission products from the detonation. These models poorly predict fallout from elevated detonations near the fallout-free height of burst (FFHOB), where interactions with the ground are limited and the mixing of fission products and lofted soil is incomplete. Fallout-free is a misnomer at this HOB, as fallout was observed in these cases, but was below the levels of concern, especially off-grounds of the nuclear test site. To correctly characterize and model fallout from detonations near the FFHOB, models must be developed which can capture the stratified nature of the particle and activity-size distributions within the cloud. Previously, it was shown that the Weather Research and Forecasting (WRF) model can accurately simulate nuclear cloud rise for airbursts with little to no ground interactions (Arthur et al., 2021). That work is expanded here by (1) using a radiation-hydrodynamics code to improve the fireball initialization in WRF, (2) further developing an aerosol package from WRF-Chem to simulate lofted soil, and (3) combining the WRF cloud rise simulations with the operational models used at the National Atmospheric Release Advisory Center (NARAC) for fallout modeling. Using this combination of codes, the Upshot-Knothole Grable detonation, which was just below the FFHOB, is simulated from seconds after detonation through cloud rise and fallout, and results are compared to historical test data. Here, the results show improved prediction of dose rate and highlight the need to correctly characterize the entrainment of material into the cloud and the subsequent mixing of fission products with entrained material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗