Search NASA⌕ Search

SEARCH · Search NASA

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ferroelectricity of wurtzite Al 1−x Hf x N heterovalent alloys

Thin films of aluminum hafnium nitride (Al1−xHfxN) were synthesized via reactive magnetron sputtering for Hf contents up to x = 0.13. X-ray diffraction showed a single c-axis oriented wurtzite phase for all films. Hard x-ray photoelectron spectroscopy demonstrated homogeneous Al:Hf distribution through the thin films and confirmed their insulating character. A collection of complementary tests showed unambiguous polarization inversion, and thus ferroelectricity in multiple samples. Current density vs electric field hysteresis measurements showed distinct ferroelectric switching current peaks, the piezoelectric coefficient d 33,f,meas measured using a double beam laser interferometer (DBLI) showed a reversal in sign with similar magnitude, and anisotropic wet etching confirmed field-induced polarization inversion. This demonstrates the possibility of using tetravalent–and not just trivalent–alloying elements to enable ferroelectricity in AlN-based thin films, highlighting the compositional flexibility of ferroelectricity in wurtzites and greatly expanding the chemistries that can be considered for future devices.

36 MATERIALS SCIENCE↗

Liquid-helium-cooled Michelson interferometer

Interferometer serves as a rocket-flight spectrometer for examination of the far infrared emission spectra of astronomical objects. The double beam interferometer is readily adapted to make spectral scans and for use as a detector of discrete line emissions.

Augason, G. C.↗

A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗

High spectral resolution ground-based observations of Venus in the 450-1250 cm sup-1 region

The thermal emission of Venus was recorded during the winter of 1970-1971, and in 1973 using the 2.7m telescope at McDonald Observatory. The double beam Michelson interferometer installed at the Coude focus was used. The spectrum was recorded between 400/cm and 1,400/cm. For the 1970 observations, the spectral resolution was 0.25/cm and the linear spatial resolution was 3/4 of the disk of Venus. In 1973 the spectral resolution was 0.20/cm with a spatial resolution 1/3 of the planetary disk. In addition to Venus, the moon, the sky adjacent to each object, and the zenith sky were recorded to help eliminate the absorption and emission effects of the earth's atmosphere.

Kunde, V. G.↗

Application of interferential correlation of spectrum to the detection of atmospheric pollutants

The general correlation principles for spectra and spectra derivatives are studied by using the Fourier transform of the spectral distribution of energy from a source illuminating a double beam interferometer with transverse splitting by dividing luminance. In this correlation technique, the use of such an interferometer has the advantage of greater luminosity as compared with a slit spectrometer. However, the correlation example indicates that it is necessary to adapt the correlator to the particular case considered, in order to obtain the best gain in the signal to noise ratio. In the case of sulfur dioxide detection, a very simple mounting which could be used in some interesting industrial applications was developed. This mounting can be used each time that the substance to be analyzed has a quasi-periodic absorption spectrum: in particular this is often the case with absorption spectra of gases, and a mounting identical to the one described for sulfur dioxide proved to be effective in the detection of nitrogen oxides.

Fortunato, G.↗

Infrared spectra of the Orgueil /C-1/ chondrite and serpentine minerals

Infrared spectroscopy of the Orgueil C-1 chondrite and polymorphs of serpentine was performed in order to further define the mineralogy of Orgueil. Spectra of the meteorite and a synthetic serpentine (Mg3(Si2O5)(OH)4) were obtained in the regions from 1400 to 200 and from 4000 to 2500 kayers using a double beam infrared spectrometer. The spectra of Orgueil are found to be incompatible with those of the chrysotile, antigorite and lizardite polymorphs of serpentine, indicating a very low abundance of these minerals in the meteorite. It is suggested that chamosite or minerals related to chamosites may prove to be compatible with the compositional, structural and infrared properties of Orgueil.

Zaikowski, A.↗

Temperature dependent UV absorption cross sections for carbonyl sulfide

The ultraviolet absorption spectrum of carbonyl sulfide is investigated in order to assess the importance of the photolytic sink for OCS in the troposphere. Absorption cross sections were measured at wavelengths between 185 and 300 nm in a double-beam spectrometer at temperatures of 295 and 225 K. The results are found to be in good agreement with previous reports in the short wavelength region, but significantly lower than the value of 2 x 10 to the 22nd sq cm/molecule proposed by Rudolf and Inn (1981) between 280 and 300 nm, which may be attributed to trace contaminants or dimerization. A marked temperature effect is noted at wavelengths greater than 240 nm and below 190 nm. As no evidence of absorption at wavelengths greater than 270 nm was found, estimates of the solar photodissociation rate of tropospheric OCS based on the present cross sections yield a value of about 2 x 10 to the -9th/sec, corresponding to a tropospheric lifetime of about 20 years. It is therefore concluded that solar photolysis represents a negligible sink for OCS.

Molina, L. T.↗

Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

Domack, M. S.↗

OH detection by Ford Motor Company

Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

Wang, Charles C.↗

Complex dielectric constants for selected near-millimeter-wave materials at 245 GHz

A double-beam instrument developed in this laboratory has been used to measure the complex dielectric constant of selected materials at 245 GHz. It is reported here the results for crystalline quartz, fused silica (Spectrosil WF and Dynasil 4000), beryllia (iso-pressed), boron nitride (hot-pressed), and a nickel ferrite (Trans-Tech 2-111). Results are compared with the data obtained by other researchers.

Dutta, J. M.↗

Ultraviolet absorption cross-sections of some carbonyl compounds and their temperature dependence

Ultraviolet absorption cross-section of phosgene (CCl2O), trichloroacetylchloride (CCl3-CClO) and trichloroacetaldehyde (CCl3-CHO) have been measured between 170 and 320 nm for temperature ranging from 210 to 295 K with classical double beam equipment. These data are compared with other available determinations performed at room temperature. Photodissociation coefficients are estimated and their temperature dependence is discussed. Impact of the photodissociation on the total atmospheric destruction of these compounds is illustrated.

Gillotay, D.↗

A review of solar wind ion and electron plasma distribution functions: Present understanding and Ulysses results

Our present understanding of the distribution functions of the solar wind ion and electron thermal/suprathermal populations will be reviewed covering selected theoretical and observational topics. Roughly half the review will be devoted to recent discoveries (since Solar Wind 7). Among recent results are those of the Ulysses mission. The SWICS experiment observed pick-up protons and alpha particles, and acceleration of these particles at interplanetary shocks. Positive ion phenomena observed by SWOOPS include enhanced proton-alpha particle differential streaming both: (1) at high latitudes; and (2) in the ecliptic beyond 1 AU in the vicinity of shocks. The SWOOPS positive ion observations also demonstrate relative constancy of the entropy per proton at high latitudes beyond about 2.5 AU. Double beaming in both protons and alphas is observed by SWOOPS on either side of the current sheet, but not within; a possible explanation is reconnection at the edge of the current sheet. SWOOPS observed bi-directional streaming of electrons beyond 2 AU not only within Coronal Mass Ejections, but also upstream of corotating interplanetary shocks. Latitudinal and radial gradients of Ulysses electron core and halo temperatures will be discussed, as will work in progress on the three dimensional (in velocity space) properties of ion distributions.

Goldstein, B. E.↗

Spectral Emittance of Uncoated and Ceramic-Coated Inconel and Type 321 Stainless Steel

The normal spectral emittance of Inconel and type 321 stainless steel with different surface treatments was measured at temperatures of 900, 1,200, 1,500, and 1,800 F over a wavelength range of 1.5 to 15 microns. The measurements involved comparison of the radiant energy emitted by the heated specimen with that emitted by a comparison standard at the same temperature by means of a recording double-beam infrared spectrophotometer. The silicon carbide comparison standard had previously been calibrated against a laboratory black-body furnace. Surface treatments included electropolishing, sandblasting, electro-polishing followed by oxidation in air for 1/2 hour at 1,800 F, sandblasting followed by oxidation in air for 1/2 hour at 1,800 F, application of National Bureau of Standards coating A-418, and application of NBS ceramic coating N-143. The normal spectral emittance of both alloys in the electropolished condition was low and decreased very slightly with increasing wavelength while in the sandblasted condition it was somewhat higher and did not vary appreciably with wavelength. The oxidation treatment greatly increased the normal spectral emittance of both the electropolished and sandblasted type 321 stainless steel specimens and of the electropolished Inconel specimens and introduced some spectral selectivity into the curves. The oxidation increased the normal spectral emittance of the sandblasted Inconel specimens only moderately. Of the specimens to which a coating about 0.002 inch thick was applied, those coated with A-418 had higher emittance at all wavelengths than did those coated with N-143, and the coated specimens of Inconel had higher spectral emittance at all wavelengths than did the corresponding specimens of type 321 stainless steel. Both coatings were found to be partially transparent to the emitted energy at this thickness but essentially opaque at a thickness of 0.005 inch. Coated specimens with 0.005 inch or more of coating did not show the effect of the underlying metal on spectral emittance, and there was no significant difference at wavelengths greater than about five microns in the normal spectral emittance of specimens having the two coatings. At shorter wavelengths the normal spectral emittance of specimens coated with A-418 was greater than that of specimens coated with N-143.

Richmond, Joseph C.↗

Equipment for Thermal-Balance Studies in the Langley Instrument Research Division

The Langley Research Center is in the process of obtaining emissivity measuring apparatus. This apparatus will be used to measure the solar absorptance and low-temperature emittance of space-vehicle materials. Two types of instrumentation will be used. One type will be the total hemispherical emissivity apparatus being constructed at this Center. The other will be double-beam photoelectric ratio-recording spectrophotometer apparatus which is being purchased.

Spiers, Robert B., Jr.↗