Search NASA⌕ Search

SEARCH · Search NASA

Results for “Droplet size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Global Survey of the Relationship Between Cloud Droplet Size and Albedo Using ISCCP

The possible indirect aerosol effect on climate is examined. First, the spatial relationship is checked between cloud droplet radii and cloud albedo in different areas where aerosol concentration are known to differ significantly. Second, the temporal relationship between r(sub e) and cloud albedo is explored for each 2.5 deg x 2.5 deg grid box to reveal in which regions of the globe the variations of cloud albedo are correlated with changes in r(sub e) consistent with the indirect aerosol effect hypothesis.

Han, Qingyuan↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameters from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, J. R.↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameterss from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, John R.↗

A Solar Reflectance Method for Retrieving Cloud Optical Thickness and Droplet Size Over Snow and Ice Surfaces

Cloud optical thickness and effective radius retrievals from solar reflectance measurements are traditionally implemented using a combination of spectral channels that are absorbing and non-absorbing for water particles. Reflectances in non-absorbing channels (e.g., 0.67, 0.86, 1.2 micron spectral window bands) are largely dependent on cloud optical thickness, while longer wavelength absorbing channels (1.6, 2. 1, and 3.7 micron window bands) provide cloud particle size information. Cloud retrievals over ice and snow surfaces present serious difficulties. At the shorter wavelengths, ice is bright and highly variable, both characteristics acting to significantly increase cloud retrieval uncertainty. In contrast, reflectances at the longer wavelengths are relatively small and may be comparable to that of dark open water. A modification to the traditional cloud retrieval technique is devised. The new algorithm uses only a combination of absorbing spectral channels for which the snow/ice albedo is relatively small. Using this approach, retrievals have been made with the MODIS Airborne Simulator (MAS) imager flown aboard the NASA ER-2 from May - June 1998 during the Arctic FIRE-ACE field deployment. Data from several coordinated ER-2 and University of Washington CV-580 in situ aircraft observations of liquid water stratus clouds are examined. MAS retrievals of optical thickness, droplet effective radius, and liquid water path are shown to be in good agreement with the in situ measurements. The initial success of the technique has implications for future operational satellite cloud retrieval algorithms in polar and wintertime regions.

Platnick, S.↗

Optical measurements of the droplet size distribution in the case of fuel atomization in swirl nozzles and planar airblast diffusers

The theoretical principles of optical methods for the determination of the particle sizes of sprays are considered and aspects of the experimental implementation of these principles are discussed. An experimental device for point-intensity measurements makes use of a helium-neon laser. The cross-sectional area of the laser beam is enlarged with the aid of a lens system to the size of the measurement cross-section. The intensity of the laser light scattered by the spray particles is measured as a function of light direction. Approaches which take into account the total energy of the diffractively scattered light are also discussed and an investigation is conducted regarding the measurement error sources. A description is presented of experimental results obtained in studies of a number of fuel nozzle sprays.

Kayser, A.↗

Performance comparison of two interferometric droplet sizing techniques

In this paper, two interferometric techniques (Visibility/Itensity Validation and Phase Doppler) are critically examined in characterizing the spray of an air-assist nozzle with Sauter mean diameter of less than 35 microns. The two techniques are compared to each other and are evaluated against a Malvern diffraction unit. With the use of a rotating grating for Visibility/Intensity Validation, the interference techniques compare well to each other and to the diffraction method. The Phase Doppler technique is more easily applied to the spray, due largely to its broadened size and velocity ranges. The consistency of the interferometric results raises questions with regard to the use of the Malvern's most frequently applied distribution model.

Jackson, T. A.↗

Droplet sizing instrumentation used for icing research: Operation, calibration, and accuracy

The accuracy of the Forward Scattering Spectrometer Probe (FSSP) is determined using laboratory tests, wind tunnel comparisons, and computer simulations. Operation in an icing environment is discussed and a new calibration device for the FSSP (the rotating pinhole) is demonstrated to be a valuable tool. Operation of the Optical Array Probe is also presented along with a calibration device (the rotating reticle) which is suitable for performing detailed analysis of that instrument.

Hovenac, Edward A.↗

A Fast Evaluation of PDA Experimental Parameters Using Mie Scattering to Enhance the Measurement Accuracy of Droplet Size Distributions

The Phase Doppler technique (PDA) and its implementation generally relies on a geometric optics formulation for light scattering to estimate drop sizes from the measured phase differences between Doppler signals from two or more detectors. Although this limits experimental PDA scattering geometries to those where only one component of the geometric scatter is dominant, the calculations are relatively simple. This TM describes a fast method to evaluate PDA experimental parameters analytically using Mie scattering that provides a performance estimate of all possible configurations. The best configurations are fully tested using a Monte Carlo simulation to obtain a more accurate capability estimate for each one.

PDA↗

Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

Yule, A. J.↗

Fluid property and operational effects on swirl injector atomization

Results of atomization tests of rocket injection elements are correlated in terms of the test fluid properties and the injection element operating conditions. The type of element modeled has a central, swirling liquid oxidizer flow; and a coaxial, axial gaseous fuel flow. Results of the correlations describe the effect of geometry, fluid properties, and operating conditions on liquid atomization. The ranges of test conditions allow reasonable extrapolation to actual high-pressure engine operating conditions. At such conditions, the swirl element should produce exceptionally finely-atomized and well-distributed spray for high combustion performance. United Technologies Research Center (UTRC) completed a test program to measure fluid spray atomization, in terms of droplet size and droplet size distributions, for swirling-flow injection elements. Element sizes and dimensions covered ranges of dimensions representative of typical cryogenic (O2/H2) liquid rocket engine practice. Relevant dimensions include the element diameter, the tangential-entry metering slot length, and the coastal fuel slot radial gap. Test fluids included water, simulated Jet-A, and Freon 113. These fluids cover ranges of properties which include or approach those of liquid oxygen. Gaseous nitrogen simulated the coaxial gaseous hydrogen fuel flow.

Cox, G. B., Jr.↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗