Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic Line Rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

General Line Ampacity State Solver

INL’s General Line Ampacity State Solver (GLASS) is a high performance software platform that enables advanced grid system operations and planning efforts to be computed in real time. It enables the combination of advanced sensors and sensor networks, communication and data transfer channels, secure and reliable data management, and real-time processing through a flexible system architecture, with the ability to support and integrate with any utility enterprise system. GLASS is designed to help resolve the problems associated with thermally limited transmission and distribution networks, namely bare overhead power transmission lines. GLASS enables the methodology of Concurrent Cooling (Dynamic Line Rating) by reducing the need of using a cost-prohibited number of weather stations (reduce the number of weather stations per mile of overhead power line) to achieve the resolution necessary for individual electric transmission line span capacity calculations. GLASS achieves this by coupling real-time grid operations data and infrastructure architecture information with real-time field deployed weather station measurements and pre-computed Computational Fluid Dynamics (CFD)-based wind modeling interpolation parameters (look-up tables). GLASS uses mathematical models based on the IEEE 738 standard and builds off of the provided iterative solution using modern software paradigms and programming styles to provide a more robust and modular software system. GLASS also interfaces in real-time with utility companies using known transmission line spans and structures. GLASS provides real-time ampacity calculations based on recent weather station data as well as transmission line specifications. GLASS also allows the user to interact graphically with internal databases, which include information such as transmission line conductor types and thermal rating limits, weather station names and locations, specific transmission line span and structure locations, as well as recent ampacity calculations.

Gentle, Jake↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Flexible Transformers

Advanced grid solutions are comprised of advanced transmission technologies and grid enhancing technologies. In this webinar, experts will provide participants with insights into eight advanced grid solutions. The advanced transmission technologies that will be discussed include point-to-point high voltage direct current and advanced conductoring and the grid enhancing technologies that experts will explore include topology optimization, advanced power flow control, dynamic line rating, energy storage, virtual power plants, and advanced flexible transformers

flexible power transformer, power flow controller,↗

Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

IEEE/CIGRE standards provide a base for overhead transmission line ratings Steady State Ampacity industry standard for Static Ratings using conservative environmental assumptions Measurement of many types of sensors provide a possibility to provide more capacity as a time varying capability Direct sensors of line temperature, tension, or sag provide critical, location specific information. Require complex transformation to determine line ampacity rating Are direct measurements sensors placed at key location(s)? Testing and careful calibration of sensors required Need to understand impact of uncertainties on sensors/measurements/ and forecasts

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Real-Time Thermal Rating Systems in the U.S. and the U.K.

Real-time thermal rating is a smart-grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative, constant seasonal rating based on seasonal and regional worst case scenarios rather than actual, say, local hourly weather predictions. This paper provides a report of two pioneering schemes-one in the U.S. and one in the U.K.-where real-time thermal ratings have been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Second, we critically compare both approaches and discuss their limitations. In doing so, we arrive at novel insights which will inform and improve future real-time thermal rating projects.

17 WIND ENERGY↗

A Guide to Case Studies of Grid Enhancing Technologies

This document has been developed as a resource for the electric power industry to rapidly understand the scale and history with which certain new technologies have been installed on or otherwise simulated to impact the transmission system. This document is attempting to address the findings of the 2022 U.S. Department of Energy (DOE) Report "Grid Enhancing Technologies: A Case Study on Ratepayer Impact", which identified the need for workforce development and training materials to transition new technologies from a state of “pilots” and “case studies” to “business-as-usual.” The authors go beyond typical survey-style literature reviews in that the key details and notes about each project are identified. Still, as will become evident, there is a need for more work to be done to increase the industry’s public knowledge on important topics related to the implementation of grid enhancing technology on the transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission Optimization with Grid Enhancing Technologies Fact Sheet

The Transmission Optimization with Grid Enhancing Technologies (TOGETs) project is funded by the Department of Energy (DOE) Office of Electricity (OE) and Wind Energy Technologies Office (WETO). Idaho National Laboratory’s TOGET Task force consists of regulatory, utility, system operator, vendor, academic, and other industry participants, who will guide a two-pronged approach to fill in gaps on publicly available knowledge of GETs and conduct a full scale, multi-faceted field exercise. Ultimately the project aims to test, verify, and validate deployed GETs in a transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TOGETs Overview

The Transmission Optimization with Grid Enhancing Technologies (TOGETs) project will guide future research to fill in gaps on publicly available knowledge of Grid Enhancing Technologies (GETs) and conduct a full scale, multi-faceted field exercise. Ultimately the project aims to test, verify and validate deployed GETs in a transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DLR Calculation Engine Interoperability Profile: A Project for the TOGETs Task Force

This document contains a detailed interoperability profile outlining how the components of the CIM can be used to implement DLR in support of the two use cases identified in the Use Case Document. An interoperability profile is defined by the Smart Electric Power Alliance (SEPA) as a document that “specifies standards-based requirements for interfaces or applications that are accepted by the user-community, testing authorities, and other stakeholders. It specifies configuration options within a standard’s requirements sufficient to deliver the desired level of interoperability and functionality.” To that end, this document is not in itself a standard, nor has it been approved by any formal body. Rather, it is an example of how to implement the CIM standard and has been reviewed by industry, including transmission operators and DLR vendors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Options for Meeting Data Center Demand in Virginia: Focus on GETs and Reconductoring [Slides]

Data center demand growth in Virginia will need to met with many options - GETs and/or reconductoring have the potential to be part of the solution suite in the short-term and medium-term. Almost all GETs and reconductoring technologies have more favorable economics than transmission wires investments considering relatively low levels of existing wide-scale deployment. Deployment of GETs and/or reconductoring is not a one size fits all - requires detailed analysis. The complementary nature of GETs and/or reconductoring impacts have the potential to be synergistic (more congestion relief, more transfer capability, more cost savings - when implemented together).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk Power System Flow Control

On July 28, 2023, the Federal Energy Regulatory Commission (FERC) issued Order Number 2023, targeting an improved generation-interconnection process in the United States. FERC Order No. 2023 requires transmission providers to evaluate transmission technologies, other than network expansion, that could provide system improvements and help expand bulk-power system capacity. Transmission providers must consider technologies that would fall under the category of Grid Enhancing Technologies (GETs), which provide capacity-expansion options other than conventional transmission expansion.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

Real-time visualization of dynamic fractures in porcine bones and the loading-rate effect on their fracture toughness

In this work we visualized, in real time, the dynamic fracture behaviors in porcine cortical bone from humerus and porcine trabecular bone from nasal bone at a high loading rate using highspeed synchrotron X-ray phase-contrast imaging (PCI). Dynamic three-point bending loading was applied on notched bone specimens by a modified Kolsky compression bar and images of the entire fracture events were recorded with an ultra-high-speed camera. Experiments at a quasi-static loading rate on material testing system (MTS) were also performed to identify the loading-rate effects on the fracture toughness of the two types of bone. Three-dimensional synchrotron X-ray computed tomography was conducted to examine the initial microstructures in the bone specimens before mechanical loading. At the dynamic loading rate, the onset locations of crack initiation were found to be independent from the bone types. The deleterious effect of dynamic loading rate on bone's fracture toughness was verified in this study and the crack was found to propagate at higher speeds in cortical bone than in trabecular bone. In a comparison of the observed more torturous crack paths at the quasi-static loading rate, cracks in dynamically loaded bone specimens generally followed the paths with less in-plane deflections and out-of-plane twists. However, our experimental results also indicated that, although the extent was diminished at dynamic loading rate, the crack deflections at osteon cement lines still played a role as a major toughening mechanism to dynamic fractures in transversely orientated cortical bone.

60 APPLIED LIFE SCIENCES↗

Slew-induced deformation shaping

Computed torques for pointing and tracking require compensation for slew-induced structural, forebody/aftbody, or optical train alignment deformations. Thus even if only line-of-sight variables are to be commanded, full state feedback is needed. The solution proposed is to decouple by feedforward of the line-of-sight slew dynamics into the deformation control loop. It is shown how arbitrarily few actuators are needed for such deformation shaping, at the cost of higher differentiability of the reference line-of-sight dynamics. The low-rate, single-axis case is developed in detail, and its extension to high rates and multiple axes by global feedback linearization is outlined.

Dwyer, T. A. W., III↗