Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic phasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Online PMU Missing Value Replacement Via Event-Participation Decomposition

We introduce a new method for online Phasor Measurement Unit (PMU) missing value replacement. Our approach allows us to decompose PMU event responses into a non-dynamic component (denoted the participation factor) that can be inferred directly from the past and a dynamic component that can be inferred directly from all other PMUs (denoted the event strength). When missing values occur, we can use these two components, which do not rely on the missing index, to estimate the correct value. The method is extremely fast and can easily be used for online applications. Furthermore, extensive testing on real power system event data reveals that our approach achieves state-of-the-art performance in terms of Mean Absolute Percent Errors (MAPEs) for PMU data dropped during event periods. Here, the method also yields an interpretable and simplified view of events for further analysis and applications. The method relies only on PMU data and does not take outside information such as network topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Induction Motors and Variable Speed Drives for Multi-Domain System Simulations Using Modelica and the OpenIPSL Library

This paper introduces an innovative method for characterizing, implementing, and validating both three-phase and single-phase induction motor models, accompanied by a variable speed drive model. The primary goal is to investigate interactions between the electrical power grid and other dynamic domains (e.g., thermofluidic) that impact motor/load drive behavior. Our approach involves establishing a mechanical interface based on a physically meaningful equation linking motor torque/speed to the electrical model in the phasor domain. This allows seamless integration of diverse domain subsystems into a unified multi-domain model using Modelica v4.0.0 and the OpenIPSL library v3.0.1, overcoming co-simulation limitations. The proposed model, which requires only one Modelica-compliant tool for simulation, introduces additional dynamics through the mechanical interface, enabling explicit simulation of load disturbances based on constitutive physics. This deepens our understanding of dynamic interactions between the electrical power domain and other subsystems connected through the motor. We detail the modeled components using mathematical equations and textual descriptions, emphasizing the Modelica modeling approach. Simulation examples validate the implementation, demonstrating the multi-domain modeling capabilities of the newly developed components.

Computer Science↗

Structure-Informed Graph Learning of Networked Dependencies for Online Prediction of Power System Transient Dynamics

Online transient analysis plays an increasingly important role in dynamic power grids as the renewable generation continues growing. Traditional numerical methods for transient analysis not only are computationally intensive but also require precise contingency information as input, and therefore, are not suitable for online applications. Existing online transient assessment studies focus on the determination of post-contingency system stability or stability margin. Here, this paper develops a novel graph-learning framework, Deep-learning Neural Representation or DNR, for online prediction, of the time-series trajectories of the system states using initial system responses that can be measured by phasor measurement units (PMUs). The proposed DNR framework consists of two sequential modules: a Network Constructor that captures network dependencies among generators, and a Dynamics Predictor that predicts the system trajectories. The key to improved prediction performance is the introduction of the spatio-temporal message-passing operations into graph neural networks with structural knowledge. Its effectiveness and scalability are validated through comparative studies, demonstrating the prediction performance under different contingency scenarios for systems of different sizes. This framework provides a solution to online predicting post-fault system dynamics based on real-time PMU measurements. Additionally, it can also be applied to facilitate the offline transient simulation without simulating the entire trajectories.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

Robust Adaptive Decentralized Dynamic State Estimation with Unknown Control Inputs using Field PMU Measurements

This paper proposes a robust adaptive decentralized dynamic state estimation method for power system with unknown inputs of the highly detailed synchronous machine model. The temporal and spatial correlations among the unknown inputs are used to derive a vector auto-regressive model. The latter is further integrated together with state transition and measurement models for joint state and unknown inputs estimation. Thanks to the consideration of implicit cross-correlations between the states and the unknown inputs, only generator terminal voltage and current phasors are needed. Test results on the US WECC system using the field PMU measurements show that the proposed method is able to track both the system dynamic states and unknown controller inputs. These information could significantly benefit the validation and calibration of generator controller parameters.

Zhao, Junbo↗

A Hybrid Framework Combining Model-Based and Data-Driven Methods for Hierarchical Decentralized Robust Dynamic State Estimation

This paper combines model-based and data-driven methods to develop a hierarchical, decentralized, robust dynamic state estimator (DSE). A two-level hierarchy is proposed, where the lower level consists of robust, model-based, decentralized DSEs. The state estimates sent from the lower level are received at the upper level, where they are filtered by a robust data-driven DSE after a principled sparse selection. This selection allows us to shrink the dimension of the problem at the upper level and hence significantly speed up the computational time. The proposed hybrid framework does not depend on the centralized infrastructure of the control centers; thus it can be completely embedded into the wide-area measurement systems. This feature will ultimately facilitate the placement of hierarchical decentralized control schemes at the phasor data concentrator locations. Also, the network model is not necessary; thus, a topology processor is not required. Finally, there is no assumption on the dynamics of the electric loads. The proposed framework is tested on the 2,000-bus synthetic Texas system, and shown to be capable of reconstructing the dynamic states of the generators with high accuracy, and of forecasting in the advent of missing data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Lossless Compression for Ultra-High-Density Synchrophasor and Point on Wave Data

Modern advanced Phasor Measurement Units (PMUs) are developed with ultra-high reporting rates to meet the demand for monitoring the power systems dynamics in detail. Due to the large volume of data, the communication and storage systems are seriously challenged with the presence of Ultra-High-Density (UHD) synchrophasor and Point on Wave (POW) data. Therefore, it is an urgent task to compress the UHD data for more efficient communication and data storage. This paper proposes several methods to compress the synchrophasor and POW data in a lossless manner. First, an Improved-Time-Series-Special Compression (ITSSC) method is proposed to compress the UHD frequency data. Second, a Delta-difference Huffman method is combined with the TSSC algorithm to compress the UHD phase angle data. Finally, a cyclical high-order delta modulation method is proposed to compress the UHD POW data. The proposed models are extensively tested and compared with different existing lossless compression algorithms using the field-collected synchrophasor and POW data at different reporting rates. The results indicate that the proposed algorithms are efficient in performing lossless compression for the UHD synchrophasor and POW data in real time.

42 ENGINEERING↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ponderomotive electron physics captured in a single-fluid extended magnetohydrodynamics model

The ponderomotive force, arising from the interaction between electromagnetic waves and plasma, plays a critical role in laser fusion, astrophysical plasmas, and laser diagnostics. Traditionally, modeling this force requires multi-fluid or particle-in-cell simulations due to its strong coupling to electron-scale dynamics. In this work, we demonstrate that a one-fluid, two-temperature extended magnetohydrodynamics (XMHD) model—augmented with a generalized Ohm's law (GOL) including electron inertia—can accurately reproduce key ponderomotive effects. We derive the ponderomotive force within this framework using a phasor-based approach and then validate its nonlinear manifestations through direct numerical simulations in the PERSEUS code, where steepening and density modulation phenomena typically associated with kinetic-scale models are reproduced. These results and prior work establish XMHD as a robust and efficient alternative for modeling nonlinear laser–plasma dynamics, bridging the gap between ideal MHD and fully kinetic approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Dynamic Power Network State Estimation with Asynchronous Measurements

The operation of distribution networks is becoming increasingly volatile, due to fast variations of renewables and, hence, net-loading conditions. To perform a reliable state estimation under these conditions, this paper considers the case where measurements from meters, phasor measurement units, and distributed energy resources are collected and processed in real time to produce estimates of the state at a fast time scale. Streams of measurements collected in real time and at heterogenous rates render the underlying processing asynchronous, and poses severe strains on workhorse state estimation algorithms. In this work, a real-time state estimation algorithm is proposed, where data are processed on the fly. Starting from a regularized least-squares model, and leveraging appropriate linear models, the proposed scheme boils down to a linear dynamical system where the state is updated based on the previous estimate and on the measurement gathered from a few available sensors. The estimation error is shown to be always bounded under mild condition. Numerical simulations are provided to corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Event Detection of Power Systems Based on Unequal-Interval Reduction of PMU Data and Local Outlier Factor

With the deployment of phasor measurement units (PMU) and wide area measurement system (WAMS), it is feasible to have an insight into the events occurred in power systems based on measured data. Thus, a novel data-driven algorithm based on local outlier factor (LOF) is proposed in this work to detect and locate events in power systems using reduced PMU data. First, the unequal-interval reduction method is presented to reduce the scale of PMU data in sub-stations and reconstruct it in master station of WAMS, which can relieve the burden of communication systems. Then, principle component analysis (PCA)-based similarity search method is proposed to measure the differences of operation state between any two buses. Next, LOF is presented to detect the abnormal events in power systems, and employed to determine the region of the event source. Finally, six cases from the Western electricity coordinating council (WECC) 179-bus power system, a case from the South China power system (SCPS), and a case from the Guangdong power system (GDPS) are utilized to demonstrate the effectiveness of the proposed algorithm. Overall, the results show that proposed algorithm is effective and can be applied to event detection, event location, and online monitoring, which can enhance the situation awareness ability of power system operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time Series Classification for Locating Forced Oscillation Sources

Here, this article presents a machine learning based time-series classification method for using synchrophasor measurements to locate the source of forced oscillation (FO) for fast disturbance removal. First, multivariate time series (MTS) matrices are constructed by the most informative measurements selected by sequential feature selection from each power plant. Then, the Mahalanobis matrix is trained such that the Mahalanobis distance between the MTSs from the same class (i.e., with the same FO source location) are minimized and from different classes (i.e., with different FO source locations) are maximized. This allows MTSs to be classified by classifiers with class membership corresponding to the location of each FO source. To meet the runtime requirements of online matching, class templates are constructed to reduce data size and improve matching efficiency. To account for uncertainty in identifying the exact beginning of an FO event, dynamic time warping is used to align the out-of-sync MTSs. IEEE 39bus and WECC 179bus systems are used for algorithm development and validation. Simulation results demonstrate that the algorithm meets online operation runtime requirement with high accuracy using misaligned data sets.

42 ENGINEERING↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-View Convolutional Neural Network for Data Spoofing Cyber-Attack Detection in Distribution Synchrophasors

Security of Distribution Synchrophasors Data (DSD) is of paramount importance as the data is used for critical smart grid applications including situational awareness, advanced protection, and dynamic control. Unfortunately, the DSD are attractive targets for malicious attackers aiming to damage grid. Data spoofing is a new class of deceiving attack, where the DSD of one Phasor Measurement Units (PMUs) is tampered by other PMUs thereby spoiling measurement based applications. In order to address this issue, a source authentication based data spoofing attack detection method is proposed using Multi-view Convolutional Neural Network (MCNN). First, common components embedded in raw frequency measurements from DSD are removed by Savitzky-Golay (SG) filter. Second, fast S transform (FST) is utilized to extract representative spatial fingerprints via time frequency analysis. Third, the spatial fingerprint is fed to MCNN, which combines dilated and standard convolutions for automatic feather extraction and source identification. Finally, according to the output of MCNN, spoofing attack detection is performed via threshold criterion. Extensive experiments with actual DSD from multiple locations in FNET/Grideye are conducted to verify the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗