Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Development and characterization of an aerosol-generated multi-method analytical particle test material

Ceria (CeO 2 ) particles with low to ultra-low loading of nickel dopant were produced using an aerosol-based, droplet-to-particle synthesis via an in-line calcination technique. This aerosol-based synthesis method enables the production of particles with a monodisperse size distribution. These produced and well-characterized, multi-element, ceria-based particles demonstrate a material exemplar for multi-method analytical testing. They were prepared from a cerium nitrate feedstock where low loading nickel dopant was added at target Ni/(Ni + Ce) atomic percents of 1 %, 0.1 %, and 0.01 %, using a nickel nitrate spike. This methodology proved to produce ceria particles doped with a dynamic range of low to ultra-low loadings of nickel over a 24-h period, with consistent size distribution, morphology, and composition. The successful incorporation of nickel was demonstrated with bulk and single particle inductively coupled plasma mass spectroscopy and revealed notable particle-to-particle elemental homogeneity. X-ray photoelectron spectroscopy demonstrated the presence of a high concentration of nickel dopant incorporated preferentially toward the surface of the particles, and that this dopant aided oxidation of surface Ce(III) atoms to Ce(IV). These particle test materials were then validated through X-ray absorption near edge spectroscopy, comparing the ultra-low 0.01 % Ni and low 1 % Ni-doped ceria samples. This revealed a more-reduced oxidation state of the nickel with an increase in dopant concentration. Finally, this work demonstrates a synthesis and systematic characterization scheme to produce multi-method analytical test particulates.

36 MATERIALS SCIENCE↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-fiber, discrete arbitrary picket-pulse shaping

Here, a novel all-fiber, hybrid pulse-shaping system based on the temporal stacking of discrete optical picket pulses combined with continuously shaped optical pulses provides 100-ps resolution with the high dynamic range and flexibility required for laser fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward a Balanced Description of Ground and Excited States with Transcorrelated F12 Methods

By correlating only the 1-particle states occupied in the reference determinant, the conventional design for the single-reference R12/F12 explicitly correlated methods biases them toward the ground-state description, thereby making the treatment of response properties of the ground state, and energies and other properties of excited states less robust. While the use of multireference methods and/or extensions of the standard SP-projected geminals can achieve a more balanced description of ground and excited states, here we show that the same goals can be achieved by extending the action of F12 correlators to the occupied and valence unoccupied 1-particle states only. This design choice reflects the strong dependence of the optimal correlation length scale of the F12 ansatz on the orbital energies/structure, and helps to avoid the unphysical raising of the ground-state energy if the F12 geminals are used to correlate pairs of all 1-particle states. The improved F12 geminal design is incorporated into the unitary transcorrelation framework to produce a unitary 2-body Hamiltonian that incorporates the short-range dynamical correlation physics for ground and low-energy excited states in a balanced manner. This explicitly correlated effective Hamiltonian reduces the basis set requirement on the correlation-consistent basis cardinal number by 1 or more over the uncorrelated counterpart for the description of ground-state coupled-cluster singles and doubles (CCSD) energies, vertical excitation energies, and harmonic vibrational frequencies of equation-of-motion CCSD low-energy excited states.

Hamiltonians↗

Dielectric-Engineered Monolayer MoS 2 Memtransistors for Brain-Inspired Computing with High Recognition Accuracy

Two-dimensional transition metal dichalcogenides (2D-TMDs)-based memtransistors have emerged as promising candidates for neuromorphic hardware due to their exceptional ability to emulate synaptic behavior. However, many existing 2D-TMDs memtransistors rely on polycrystalline channels with grain boundaries or defects introduced through postgrowth treatments, raising concerns about material integrity and the preservation of intrinsic properties. Here, in this work, we demonstrate a monocrystalline monolayer MoS 2 memtransistor fabricated on a silicon nitride (SiN X ) substrate, achieving a large resistive switching ratio of 10 4 , a dynamic range exceeding 90, along with highly linear and symmetric weight updates, minimal cycle-to-cycle variability, and low device-to-device variability. These attributes are critical for enabling high-performance neuromorphic hardware. Based on experimental data, we further show that these artificial synapses enable a recognition accuracy of more than 97% on the MNIST handwritten digits data set. Our findings present a straightforward approach to realizing 2D-TMDs memtransistors through dielectric engineering, offering a promising platform for next-generation neuromorphic computing systems.

2D TMDs↗

High-Sensitivity DNA Aptasensors for Detecting Salivary Biomarker S100A7 in Heart Failure

Early detection of heart failure (HF) is vital for improving patient outcomes, lowering hospital readmission rates, and enabling prompt treatment. We present the first high-affinity DNA aptamer for the salivary HF biomarker S100A7 and its application in highly sensitive, noninvasive diagnostic tests. Iterative truncation of the initial 82-nt aptamer (17–82) produced a 43-nt core (17–43) with a binding affinity of 27 nM, which was further enhanced to 5.5 nM through dimerization. Biochemical and mutational studies confirmed that 17–43 adopts a G-quadruplex structure, which is essential for S100A7 recognition and resistance to enzymatic degradation in human saliva. Incorporating 17–43 into sandwich aptamer-ELISA and hybrid aptamer–antibody ELISA assays allowed detection of recombinant S100A7 in human saliva with limits of detection (LOD) of 7.4 ng mL–1 (0.6 nM) and 29 pg/mL (2.2 pM), respectively-outperforming commercial immunoassays in both sensitivity and dynamic range. The hybrid assay maintained its full performance after 2.5 months of room temperature storage. Additionally, a biolayer interferometry (BLI) sensor with 17–43 quantified S100A7 in patient saliva (n = 3), achieving a LOD of 3.2 ng mL–1 (0.3 nM) with a total assay time of less than 20 min. The aptamer’s stability, high specificity, and versatility across biosensing platforms establish it as a promising tool for noninvasive heart failure diagnostics, laying the groundwork for portable aptamer-based biosensors for multiplexed monitoring of HF biomarkers.

DNA aptamer↗

Chemistry of Sugar Formation in the Gas Phase: Following the Activated Aldehyde

Sugars are produced by living organisms, and are required building blocks for life as we know it, which raises the foundational question of how sugars formed in a prebiotic environment. The abiotic formose reaction produces sugars from formaldehyde, but our understanding of its initiation step remains murky, with chemists invoking the concept of an “activated aldehyde” to seed this reaction. Singlet hydroxycarbenes, high-energy isomers of aldehydes, were recently reported to facilitate sugar formation under cold, nonaqueous conditions relevant to interstellar environments. Here, we generate singlet methylhydroxycarbene ( 1 CH 3 –C̈–OH) from the photodissociation of pyruvic acid and experimentally measure its gas-phase reaction with d 4 -acetaldehyde using multiplexed photoionization mass spectrometry. The C 4 H 4 D 4 O 2 isomer d 4 -acetoin is the sole product, which we kinetically link to the reactant CH 3 –C̈–OH, and attribute to a carbonyl-ene formation mechanism. We see no evidence of 3-hydroxybutanal, the C–H insertion product expected in carbene chemistry. Using automated exploration we calculate stationary points on the potential energy surface and report master equation rate coefficients from T = 20–600 K, providing quantitative kinetics of this fast reaction for use in chemical models. The prereactive complex in this reaction is stabilized by both hydrogen bonding and electrophilic carbene C═O interactions. These effects create a short-range dynamical bottleneck for the reaction besides the long- and midrange barrierless bottlenecks. Combined with recent reports of 1 HC̈OH production from methanol photodissociation and pyruvic acid production in cold irradiated ices, this work provides evidence that singlet hydroxycarbene + aldehyde chemistry is a feasible path to prebiotic sugar formation.

aldehydes↗

Highly multiplexed design of an allosteric transcription factor to sense new ligands

Allosteric transcription factors (aTF) regulate gene expression through conformational changes induced by small molecule binding. Although widely used as biosensors, aTFs have proven challenging to design for detecting new molecules because mutation of ligand-binding residues often disrupts allostery. Here, we develop Sensor-seq, a high-throughput platform to design and identify aTF biosensors that bind to non-native ligands. We screen a library of 17,737 variants of the aTF TtgR, a regulator of a multidrug exporter, against six non-native ligands of diverse chemical structures – four derivatives of the cancer therapeutic tamoxifen, the antimalarial drug quinine, and the opiate analog naltrexone – as well as two native flavonoid ligands, naringenin and phloretin. Sensor-seq identifies biosensors for each of these ligands with high dynamic range and diverse specificity profiles. The structure of a naltrexone-bound design shows shape-complementary methionine-aromatic interactions driving ligand specificity. To demonstrate practical utility, we develop cell-free detection systems for naltrexone and quinine. Sensor-seq enables rapid and scalable design of new biosensors, overcoming constraints of natural biosensors.

59 BASIC BIOLOGICAL SCIENCES↗

Defect-engineered monolayer MoS 2 with enhanced memristive and synaptic functionality for neuromorphic computing

Two-dimensional transition metal dichalcogenides (TMDs)-based memristors are promising candidates for realizing artificial synapses in next-generation computing. However, practical implementation faces several challenges, such as high non-linearity and asymmetry in synaptic weight updates, limited dynamic range, and cycle-to-cycle variability. Here, utilizing optimal-power argon plasma treatment, we significantly enhance the performance matrix of memristors fabricated from monolayer MoS 2 . Our approach not only improves linearity and symmetry in synaptic weight updates but also increases the number of available synaptic weight updates and enhances Spike-Time Dependent Plasticity. Notably, it broadens the switching ratio by two orders, minimizes cycle-to-cycle variability, reduces non-linear factors, and achieves an energy consumption of ~30 fJ per synaptic event. Implementation of these enhancements is demonstrated through Artificial Neural Network simulations, yielding a learning accuracy of ~97% on the MNIST hand-written digits dataset. Our findings underscore the significance of defect engineering as a powerful tool in advancing the synaptic functionality of memristors.

97 MATHEMATICS AND COMPUTING↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel deuterium–tritium (DT) neutron activation diagnostics for increased neutron yield operations at Sandia’s Z-facility (invited)

As inertial confinement fusion experiments at Sandia National Laboratories’ Z-facility begin using deuterium–tritium (DT) fuels, the expected DT-neutron yields are expected to increase many orders of magnitude. This brings about the need for diagnostics that have a significantly higher dynamic range of operation and ability to obtain yields where there will be significant radiation holds. Using the current activation diagnostic infrastructure at the Z-facility, a pair of activation diagnostics are being developed. Here, the first is fluorine activation, which will be used in a similar manner to current copper activation diagnostics that are fielded in a rabbit for quick removal from the experiments without opening the vacuum experiment containment. The second is a prompt DT-neutron detector that exploits the activation of oxygen with similar operation characteristics as the current Be-probes fielded at Z. We will discuss the design of this pair of instruments, along with calibration work performed at Sandia’s Ion Beam Laboratory in support of the development and anticipated instrument performance.

Mangan, Michael Antony↗