Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

The validation of LIMS ozone profiles using correlative rocket, ECC, and Dobson data sets

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment is a limb scanning infrared sounder designed to measure vertical temperature profiles and the concentrations of key chemical compounds which are important in the stratospheric ozone-nitrogen photochemistry. Preliminary ozone profiles are being intercompared with correlative rocket and balloonsonde ozone data sets as part of the Nimbus 7 LIMS data validation activity. The LIMS ozone retrievals extend from the lower mesosphere to the tropopause (or cloud-top altitudes). In this paper, preliminary statistics of comparisons of ECC (electrochemical concentration cell) ozonesonde and rocket ozone profiles with LIMS ozone profiles are presented. ECC ozonesonde data taken at times of LIMS overpasses are also used to extend the LIMS retrieval down to ground level. Each combined profile is then integrated to obtain total column ozone. These integrated results are compared to Dobson data obtained at approximately the same time and location.

Remsberg, E. E.↗

Satellite and correlative measurements of stratospheric ozone - Comparison of measurements made by SAGE, ECC balloons, chemiluminescent, and optical rocketsondes

The validity of ozone-profile data from the satellite sensor SAGE was tested in a series of correlative experiments conducted at five fixed sites between 6 deg S and 65 deg N during 1979-1980. The intercomparisons included data taken with electrochemical ozone (ECC) balloonsondes and chemiluminescent and optical rocketsondes. The average mean difference for 17 separate comparisons between the SAGE and ECC balloonsonde observations over the altitudes 18-28 km was 9.3 percent with a standard deviation of 2.8 percent. Excluding comparisons separated by greater than 500 km reduces the average mean difference to 8.9 percent and the standard deviation to 2.1 percent. The average mean difference between SAGE and three optical rocketsonde observations over the altitudes 25-50 km was 11 percent, and between SAGE and two chemiluminescent rocketsondes over the altitudes 20-60 km it was 13.5 percent. Considering the differences in vertical resolution, experimental errors, and ozone time and space gradients, the agreement between SAGE-derived ozone profiles and these correlative measurements is considered very good. In addition, isopleths of ozone mixing ratio versus latitude and altitude are in good agreement with previously published results.

Mccormick, M. P.↗

Performance-based ECCS cladding acceptance criteria: A new simulation approach

The U. S. Nuclear Regulatory Commission is currently proposing rulemaking to revise the Loss Of Coolant Accident (LOCA) and therefore the Emergency Core Cooling System (ECCS) acceptance criteria, to include the effects of higher burnup on cladding performance as well as to address other technical issues. As motivated by the new rule, the need to use advanced cladding designs may be a result. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost, as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently, there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin. The study here presented has been part of a big project used to investigate technical issues and approaches for future industrial applications within the Risk-Informed Safety Margin Characterization (RISMC) Pathway. Specifically, the primary aim of this study is to lay out a roadmap to demonstrate the application of the new methodology. Furthermore, the present analysis shows a simplified version of the methodology of an industrial application on the Core Design and the Multi-Cycle Analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autogenous healing of Engineered Cementitious Composites (ECC) based on MgO-fly ash binary system activated by carbonation curing

Developing self-healing of concrete cracks represents a critical approach for extending material longevity. If demonstrated on concretes with CO 2 stored through carbonation curing, self-healing can further mitigate infrastructure lifecycle emissions. In this study, the self-healing process is investigated on novel Engineered Cementitious Composites (ECC) based on binary blends of reactive MgO cement and siliceous fly ash activated by carbonation. The self-healing was observed under cyclic wetting and drying exposures and was characterized by measurements of resonance frequency, optical microscopy and X-ray computed microtomography (XCT). Thermogravimetric analysis, X-ray powder diffraction and scanning electron microscopy were employed to assist in identifying healing products and mechanisms. It was found that micro-cracks could be autogenously filled in 7 wet-dry cycles, as evidenced by over 95% recovery of resonance frequency and healed crack appearance under optical microscopic observation. Nevertheless, the composite mechanical performance, particularly tensile strength and ductility, did not fully recover with respect to the uncracked specimens. The inadequate post-healing mechanical properties were consistent with XCT observations that indicated low material densities in the cracked area. Based on the chemical and microstructural characterizations, it was determined that nesquehonite crystallites were responsible for the crack filling. Although the nesquehonite filled cracks will be less permeable to invasion of reactive fluids, novel strategies are needed to establish more robust healing capability to completely restore the crack bridging and composite tensile performance.

36 MATERIALS SCIENCE↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Industry Application ECCS / LOCA Integrated Cladding/Emergency Core Cooling System Performance: Demonstration of LOTUS-Baseline Coupled Analysis of the South Texas Plant Model

Under the auspices of the DOE LWRS Program RISMC Industry Application ECCS/LOCA, INL has engaged staff from both South Texas Project (STP) and the Texas A&M University (TAMU) to produce a generic pressurized water reactor (PWR) model including reactor core, clad/fuel design and systems thermal hydraulics based on the South Texas Project (STP) nuclear power plant, a 4-Loop Westinghouse PWR. A RISMC toolkit, named LOCA Toolkit for the U.S. (LOTUS), has been developed for use in this generic PWR plant model to assess safety margins for the proposed NRC 10 CFR 50.46c rule, Emergency Core Cooling System (ECCS) performance during LOCA. This demonstration includes coupled analysis of core design, fuel design, thermalhydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results. Within this context, a multi-physics best estimate plus uncertainty (MPBEPU) methodology framework is proposed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ECC Refrigerator: Characterize Performance of a Prototype Electrochemical Compressor

This report documents experimental study to characterize performance of a prototype electrochemical compressor, provided by Xergy INC. It describes the working mechanism and its electrochemical efficiency and isentropic compression efficiency. The experimental results demonstrate that the prototype compressor is able to pump hydrogen flow from 25 psia to 140 psia, and deliver the flow rate as predicted. On the other hand, its efficiency level is low, having the electrochemical efficiency less than 40%, and isentropic efficiency below 47%. Using two identical ECC compressors in parallel will reduce the current density and ohm loss, which can increase the isentropic efficiency up to 67% with increased cost. Further improvements on the compressor are suggested, e.g. using more conductive membrane, etc.

42 ENGINEERING↗

Effects of solution mass transport on the ECC ozonesonde background current

Measurement of the mass transport rate constant for the electrochemical concentration cell in an ozonesonde as a function of the pressure is reported. The investigation was performed to accurately model the residual current present in the ECC cell in the absence of ozone. The convective mass transport for two sondes were determined while maintaining a sufficiently negative cathodic potential to eliminate electron transfer at the cathode surface. A sonde was placed in a bell jar and subjected to varying pressure levels. When the background current was kept below 0.1 microamp and pressure was from 100-1000 mb, the necessary correction term for the pressure was independent of pressure. However, below 100 mb, a logarithmic decrease in the background current with pressure is expected. Present practices, involving a sensitivity to oxygen, are calculated to result in overestimation of the total ozone between 1000-10 mb by 0.0096 atm-cm with a background current of 0.1 microamp at 1000 mb.

Thornton, D. C.↗

The latitudinal distribution of ozone to 35 km altitude from ECC ozonesonde observations, 1982-1990

Electrochemical concentration cell (ECC) ozone-sonde observations, made in recent years at ten stations whose locations range from the Arctic to Antarctica, have yielded a self-consistent ozone data base from which mean seasonal and annual latitudinal ozone vertical distributions to 35 km have been derived. Ozone measurement uncertainties are estimated, and results are presented in the Bass-Paur (1985) ozone absorption coefficient scale adopted for use with Dobson ozone spectrophotometers January 1, 1992. The data should be useful for comparison with model calculations of the global distribution of atmospheric ozone, for serving as apriori statistical information in deriving ozone vertical distributions from satellite and Umkehr observations, and for improving the satellite and Umkehr ozone inversion algorithms. Attention is drawn to similar results based on a less comprehensive data set published in Ozone in the Atmosphere, Proceedings of the 1988 Quadrennial Ozone Symposium where errors in data tabulations occurred for three of the stations due to inadvertent transposition of ozone partial pressure and air temperature values.

Komhyr, W. D.↗

Combined group ECC protection and subgroup parity protection

A method and system are disclosed for providing combined error code protection and subgroup parity protection for a given group of n bits. The method comprises the steps of identifying a number, m, of redundant bits for said error protection; and constructing a matrix P, wherein multiplying said given group of n bits with P produces m redundant error correction code (ECC) protection bits, and two columns of P provide parity protection for subgroups of said given group of n bits. In the preferred embodiment of the invention, the matrix P is constructed by generating permutations of m bit wide vectors with three or more, but an odd number of, elements with value one and the other elements with value zero; and assigning said vectors to rows of the matrix P.

97 MATHEMATICS AND COMPUTING↗

10826-ECC-CA-FY24Q1-BP1Q3

Emerald Cities Collaborative (ECC) is piloting a replicable model to increase the supply and diversity of technicians entering the solar/electrical workforces to meet demand for renewable energy, electrification, and energy efficiency.

14 SOLAR ENERGY↗

Loss of Coolant Accident (LOCA) / Emergency Core Coolant System (ECCS Evaluation of Risk-Informed Margins Management Strategies for a Representative Pressurized Water Reactor (PWR)

A Risk Informed Safety Margin Characterization (RISMC) toolkit and methodology are proposed for investigating nuclear power plant core, fuels design and safety analysis, including postulated Loss-of-Coolant Accident (LOCA) analysis. This toolkit, under an integrated evaluation model framework, is name LOCA toolkit for the US (LOTUS). This demonstration includes coupled analysis of core design, fuel design, thermal hydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗