Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Building a Long-Lived 3D Multimode Quantum Processing Unit with TESLA Cavities

Superconducting radio-frequency (SRF) cavities, such as TESLA-shaped cavities, are excellent candidates for long-lived quantum memories. Integrating these cavities with nonlinear elements, such as transmons, enables universal quantum control; however, this integration can often introduce unwanted losses. In this talk, we present the successful integration of a long-lived 2-cell TESLA cavity with an ancillary qubit, forming a quantum processing unit (QPU) that allows for robust control while maintaining coherence. We demonstrate universal control of the QPU through various schemes, including ancilla-cavity sideband and echoed conditional displacement (ECD) methods, enabling fault-tolerant high-fidelity preparation of large Fock states and fast entanglement generation. These results illustrate the versatility and efficiency of our 3D quantum processing unit, paving the way for advanced quantum computing applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

De novo synthesis and near atomic resolution imaging of host immune receptors critical for pathogen recognition (Abbreviated Final Report)

The innate immune system serves as the body’s first line of defense against invading pathogens, responding rapidly through the deployment of immune cells at common sites of infection, such as the skin and airways. These immune-cell sentinels express a range of highly conserved receptors, including Toll-like receptors (TLRs), which recognize and bind to pathogen-derived components. This recognition event triggers intracellular signaling cascades that initiate and coordinate immune responses. Despite their significance, the complete structural characterization of full-length TLRs, including their extracellular domain (ECD), transmembrane domain (TMD), and Toll/interleukin-1 receptor (TIR) domain, remains incomplete. In this study, we examined the expression and isolation of human TLR4 incorporated into nanodiscs using two approaches: a cell-free synthesis system and a cell-based transfection strategy employing Expi293F cells derived from the human embryonic kidney lineage. Our findings demonstrate that NLP-bound human TLR4 produced via the cell-based method yielded functional protein suitable for time-resolved single-particle cryo-electron microscopy (cryo-EM). This advancement enables structural characterization of full-length TLR4, maintaining the integrity of its extracellular domain, transmembrane domain, and Toll/Interleukin-1 receptor (TIR) domain.

59 BASIC BIOLOGICAL SCIENCES↗

Aculeaxanthones A–E, new xanthones from the marine-derived fungus Aspergillus aculeatinus WHUF0198

Introduction Dimeric natural products are widespread in plants and microorganisms, which usually have complex structures and exhibit greater bioactivities than their corresponding monomers. In this study, we report five new dimeric tetrahydroxanthones, aculeaxanthones A−E ( 4−8 ), along with the homodimeric tetrahydroxanthone secalonic acid D ( 1 ), chrysoxanthones B and C ( 2 and 3 ), and 4−4’-secalonic acid D ( 9 ), from different fermentation batches of the title fungus. Methods A part of the culture was added to a total of 60 flasks containing 300 ml each of number II fungus liquid medium and culture 4 weeks in a static state at 28˚C. The liquid phase (18 L) and mycelia was separated from the fungal culture by filtering. A crude extract was obtained from the mycelia by ultrasound using acetone. To obtain a dry extract (18 g), the liquid phase combined with the crude extract were further extracted by EtOAc and concentrated in vacuo. The MIC of anaerobic bacteria was examined by a broth microdilution assay. To obtain MICs for aerobic bacteria, the agar dilution streak method recommended in Clinical and Laboratory Standards Institute document (CLSI) M07-A10 was used. Compounds 1−9 was tested against the Bel-7402, A-549 and HCT-116 cell lines according to MTT assay. Results and Discussion The structures of these compounds were elucidated on the base of 1D and 2D NMR and HR-ESIMS data, and the absolute configurations of the new xanthones 4−8 were determined by conformational analysis and time-dependent density functional theory-electronic circular dichroism (TDDFT-ECD) calculations. Compounds 1–9 were tested for cytotoxicity against the Bel-7402, A549, and HCT-116 cancer cell lines. Of the dimeric tetrahydroxanthone derivatives, only compound 6 provided cytotoxicity effect against Bel-7402 cell line (IC50, 1.96 µM). Additionally, antimicrobial activity was evaluated for all dimeric tetrahydroxanthones, including four Gram-positive bacteria including Enterococcus faecium ATCC 19434, Bacillus subtilis 168, Staphylococcus aureus ATCC 25923 and MRSA USA300; four Gram-negative bacteria, including Helicobacter pylori 129, G27, as well as 26,695, and multi drug-resistant strain H. pylori 159, and one Mycobacterium M. smegmatis ATCC 607. However, only compound 1 performed activities against H. pylori G27, H. pylori 26695, H. pylori 129, H. pylori 159, S. aureus USA300, and B. subtilis 168 with MIC values of 4.0, 4.0, 2.0, 2.0, 2.0 and 1.0 μg/mL, respectively.

Wu, Jun↗

Potential seal candidates for high-energy propellants

Five potential seal candidates (linear Tefzel, linear Halar, crosslinked Halar, Viton ECD-006, and phosphazine fluoroelastomer) were evaluated for the orbital maneuvering system of the space shuttle. Since this system employs nitrogen tetroxide (N2O4) and monomethyl hydrazine (MMH) as hypergolic propellants, the seal candidates were selected on the basis of projected chemical resistance as well as rheological behavior. Chemical resistance to these high-energy fuels was determined via conventional isothermal and thermal cycling immersion tests. Rheological measurements, however, were performed on O-rings molded from the subject seal candidates. Properties determined, such as cyclic work and hysteresis, stress relaxation, and indicated modulus, therefore, relate to the O-ring seals themselves.

Merz, P. L.↗

The active titration method for measuring local hydroxyl radical concentration

We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

Sprengnether, Michele↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Emergency medical service (EMS): A unique flight environment

The EMS flight environment is unique in today's aviation. The pilots must respond quickly to emergency events and often fly to landing zones where they have never been before . The time from initially receiving a call to being airborne can be as little as two to three minutes. Often the EMS pilot is the only aviation professional on site, they have no operations people or other pilots to aid them in making decisons. Further, since they are often flying to accident scenes, not airports, there is often complete weather and condition information. Therefore, the initial decision that the pilot must make, accepting or declining a flight, can become very difficult. The accident rate of EMS helicopters has been relatively high over the past years. NASA-Ames research center has taken several steps in an attempt to aid EMS pilots in their decision making and situational awareness. A preflight risk assessment system (SAFE) was developed to aid pilots in their decision making, and was tested at an EMS service. The resutls of the study were promising and a second version incorporating the lessons learned is under development. A second line of research was the development of a low cost electronic chart display (ECD). This is a digital map display to help pilots maintain geographical orientation. Another thrust was undertaken in conjunction with the Aviation Safety Reporting System (ASRS). This involved publicizing the ASRS to EMS pilots and personnel, and calling each of the reporters back to gather additional information. This paper will discuss these efforts and how they may positively impact the safety of EMS operations.

Shively, R. Jay↗

Differential Mobility Spectrometry: Preliminary Findings on Determination of Fundamental Constants

The electron capture detector (ECD) has been used for 40+ years (1) to derive fundamental constants such as a compound's electron affinity. Given this historical perspective, it is not surprising that differential mobility spectrometry (DMS) might be used in a like manner. This paper will present data from a gas chromatography (GC)-DMS instrument that illustrates the potential capability of this device to derive fundamental constants for electron-capturing compounds. Potential energy curves will be used to provide possible explanation of the data.

Limero, Thomas↗

MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices

A method of fabricating Bi(2-x)Sb(x)Te3-based thermoelectric microdevices involves a combination of (1) techniques used previously in the fabrication of integrated circuits and of microelectromechanical systems (MEMS) and (2) a relatively inexpensive MEMS-oriented electrochemical-deposition (ECD) technique. The present method overcomes the limitations of prior MEMS fabrication techniques and makes it possible to satisfy requirements.

Lim, James↗

The Observed Response of Ozone Monitoring Instrument (OMI) NO2 Columns to NOx Emission Controls on Power Plants in the United States: 2005-2011

We show that Aura Ozone Monitoring Instrument (OMI) nitrogen dioxide (NO2) tropospheric column data may be used to assess changes of the emissions of nitrogen oxides (NOx) from power plants in the United States, though careful interpretation of the data is necessary. There is a clear response for OMI NO2 data to NOx emission reductions from power plants associated with the implementation of mandated emission control devices (ECDs) over the OMI record (2005e2011). This response is scalar for all intents and purposes, whether the reduction is rapid or incremental over several years. However, it is variable among the power plants, even for those with the greatest absolute decrease in emissions. We document the primary causes of this variability, presenting case examples for specific power plants.

remote sensing↗

VeloxChem: A Python-driven density-functional theory program for spectroscopy simulations in high-performance computing environments

An open-source program named VeloxChem has been developed for the calculation of electronic real and complex linear response functions at the levels of Hartree–Fock and Kohn–Sham density functional theories. With an object-oriented program structure written in a Python/C++ layered fashion, VeloxChem enables time-efficient prototyping of novel scientific approaches without sacrificing computational efficiency, so that molecular systems involving up to and beyond 500 second-row atoms (or some 10,000 contracted and in part diffuse Gaussian basis functions) can be routinely addressed. In addition, VeloxChem is equipped with a polarizable embedding scheme for the treatment of the classical electrostatic interactions with an environment that in turn is modeled by atomic site charges and polarizabilities. The underlying hybrid message passing interface (MPI)/open multiprocessing (OpenMP) parallelization scheme makes VeloxChem suitable for execution in high-performance computing cluster environments, showing even slightly beyond linear scaling for the Fock matrix construction with use of up to 16,384 central processing unit (CPU) cores. An efficient—with respect to convergence rate and overall computational cost—multifrequency/gradient complex linear response equation solver enables calculations not only of conventional spectra, such as visible/ultraviolet/X-ray electronic absorption and circular dichroism spectra, but also time-resolved linear response signals as due to ultra-short weak laser pulses.

97 MATHEMATICS AND COMPUTING↗