Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC FIELD STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Correlations between solar wind parameters and auroral kilometric radiation intensity

The relationship between solar wind properties and the influx of energy into the nightside auroral region as indicated by the intensity of auroral kilometric radiation is investigated. Smoothed Hawkeye satellite observations of auroral radiation at 178, 100 and 56.2 kHz for days 160 through 365 of 1974 are compared with solar wind data from the composite Solar Wind Plasma Data Set, most of which was supplied by the IMP-8 spacecraft. Correlations are made between smoothed daily averages of solar wind ion density, bulk flow speed, total IMF strength, electric field, solar wind speed in the southward direction, solar wind speed multiplied by total IMF strength, the substorm parameter epsilon and the Kp index. The greatest correlation is found between solar wind bulk flow speed and auroral radiation intensity, with a linear correlation coefficient of 0.78 for the 203 daily averages examined. A possible mechanism for the relationship may be related to the propagation into the nightside magnetosphere of low-frequency long-wavelength electrostatic waves produced in the magnetosheath by the solar wind.

Gallagher, D. L.↗

Microwave heating and joining of ceramic cylinders: A mathematical model

A thin cylindrical ceramic sample is placed in a single mode microwave applicator in such a way that the electric field strength is allowed to vary along its axis. The sample can either be a single rod or two rods butted together. We present a simple mathematical model which describes the microwave heating process. It is built on the assumption that the Biot number of the material is small, and that the electric field is known and uniform throughout the cylinder's cross-section. The model takes the form of a nonlinear parabolic equation of reaction-diffusion type, with a spatially varying reaction term that corresponds to the spatial variation of the electromagnetic field strength in the waveguide. The equation is analyzed and a solution is found which develops a hot spot near the center of the cylindrical sample and which then propagates outwards until it stabilizes. The propagation and stabilization phenomenon concentrates the microwave energy in a localized region about the center where elevated temperatures may be desirable.

Booty, Michael R.↗

Electrochromatographic separation of proteins

We have developed a modified electrochromatography system which minimizes Joule heating at electric field strengths up to 125 V/cm. A non-linear equilibrium model is described which incorporates electrophoretic mobility, hydrodynamic flow velocity, and an electrically induced concentration polarization at the surface of the stationary phase. This model is able to provide useful estimates of protein retention time and velocity in a column packed with Sephadex gel and subjected to an electric field. A correlation of electrophoretic mobility of peptide and proteins with respect to their charge, molecular mass, and asymmetry enables the selection of solute target molecules for electrochromatographic separations. Good separation of protein mixtures have been obtained.

NASA Discipline Life Support Systems↗

The electromagnetic environment at S- and Ku-band frequencies for the Space Station Freedom

The purpose of this paper is to quantify the electric field strength around the Space Station Assembly/Contingency Subsystem (ACS) S-band conical horn antenna and the Space-to-Ground Subsystem (SGS) Ku-band 6-ft diameter reflector antenna. The regions in which the electric fields exceed the specified maximum permitted RF exposure of the Extravehicular Mobility Unit electronics equipment and EVA astronaut are identified for the Space Station ACS S-band conical horn antenna and the SGS Ku-band 6-ft diameter reflector antenna, respectively. The scattering effects of a flat metal plate, a representative Space Station structural element, were also examined. It was shown that the reflected waves from the reflecting structure cause both destructive and constructive interference of the electric fields in the intersection region between the incident and reflected waves.

Hwu, Shian U.↗

Airborne observations of electric fields around growing and decaying cumulus clouds

Airborne electric field data were gathered in an atmospheric electrification study near Cape Canaveral, FL. A Learjet 36A was instrumented with eight electric field meters (mills) and five different particle probes. The local electric field enhancements at each field mill site were determined under lab conditions and verified using in-flight data. The overdetermined system of eight equations (one for each field mill) was solved using a weighted least squares algorithm to compute the magnitude and direction of the ambient electric field. The signal processing system allowed the measured data to be expressed in terms of earth coordinates, regardless of the attitude of the aircraft. Thus, it was possible to take maximum advantage of the Learjet's speed and maneuverability in studying the electric field structure in the vicinity of the clouds. Data gathered while circling just outside the boundary of a growing cumulus cloud show a nonsymmetric pattern of electric field strength. Field intensity grew rapidly over a period of less than 10 minutes. The observed direction of the ambient electric field vector can be explained by an ascending motion of the charge centers of a classic tripole model of a thunderstorm.

Giori, K. L.↗

Approximations useful for the prediction of electrostatic discharges for simple electrode geometries

The report provides approximations for estimating the capacitance and the ratio of electric field strength to potential for a certain class of electrode geometries. The geometry consists of an electrode near a grounded plane, with the electrode being a surface of revolution about the perpendicular to the plane. Some examples which show the accuracy of the capacitance estimate and the accuracy of the estimate of electric field over potential can be found in the appendix. When it is possible to estimate the potential of the electrode, knowing the ratio of electric field to potential will help to determine if an electrostatic discharge is likely to occur. Knowing the capacitance will help to determine the strength of the discharge (the energy released by it) if it does occur. A brief discussion of discharge mechanisms is given. The medium between the electrode and the grounded plane may be a neutral gas, a vacuum, or an unchanged homogeneous isotropic dielectric.

Edmonds, L.↗

Approximations useful for the prediction of electrostatic discharges for simple electrode geometries

The report provides approximations for estimating the capacitance and the ratio of electric field strength to potential for a certain class of electrode geometries. The geometry consists of an electrode near a grounded plane, with the electrode being a surface of revolution about the perpendicular to the plane. Some examples which show the accuracy of the capacitance estimate and the accuracy of the estimate of electric field over potential can be found in the appendix. When it is possible to estimate the potential of the electrode, knowing the ratio of electric field to potential will help to determine if an electrostatic discharge is likely to occur. Knowing the capacitance will help to determine the strength of the discharge (the energy released by it) if it does occur. A brief discussion of discharge mechanisms is given. The medium between the electrode and the grounded plane may be a neutral gas, a vacuum, or an unchanged homogeneous isotropic dielectric.

Edmonds, Larry D.↗

Magnetospheric electron density measurements from upper hybrid resonance noise observed by IMP-6

A band of natural radio noise between the local electron plasma frequency and the upper hybrid resonance frequency is observed by the IMP-6 satellite. The band exists over a large range of geocentric radial distances extending from inside the plasmapause boundary to greater than 10 earth radii in the outer magnetosphere. The center frequency of the noise band decreases with increasing radial distance, and changes abruptly at the plasmapause boundary. The broadband electric field strength of this noise is very small, seldom exceeding 10 microvolts/meter, and probably could not be detected without using long electric antennas of IMP-6. It is believed that this noise is produced by incoherent Cerenkov emission from super-thermal electrons. In some cases a second very narrow noise band was observed at a frequency slightly above the second harmonic of the electron gyrofrequency.

Shaw, R. R.↗

Electrohydrodynamic Pool Boiling in Reduced Gravity

This research is concerned with studying the effects of applied electric fields on pool boiling in a reduced-gravity environment. Experiments are conducted at the NASA Lewis 2.2 sec Drop tower using a drop rig constructed at UC Davis. In the experiments, a platinum wire is heated while immersed in saturated liquid refrigerants (FC-72 and FC-87), or water, causing vapor formation at the wire surface. Electric fields are applied between the wire surface and an outer screen electrode that surrounds the wire. Preliminary normal-gravity experiments with water have demonstrated that applied electric fields generated by the rig electronics can influence boiling characteristics. Reduced-gravity experiments will be performed in the summer of 1996. The experiments will provide fundamental data on electric field strengths required to disrupt film boiling (for various wire heat generation input rates) in reduced gravity for a cylindrical geometry. The experiments should also shed light on the roles of characteristic bubble generation times and charge relaxation times in determining the effects of electric fields on pool boiling. Normal-gravity comparison experiments will also be performed.

Shaw, Benjamin D.↗

Electron plasma oscillations in the Venus foreshock

Plasma waves are observed in the solar wind upstream of the Venus bow shock by the Pioneer Venus Orbiter. These wave signatures occur during periods when the interplanetary magnetic field through the spacecraft position intersects the bow shock, thereby placing the spacecraft in the foreshock region. The electron foreshock boundary is clearly evident in the data as a sharp onset in wave activity and a peak in intensity. Wave intensity is seen to drop rapidly with increasing penetration into the foreshock. The peak wave electric field strength at the electron foreshock boundary is found to be similar to terrestrial observations. A normalized wave spectrum was constructed using measurements of the electron plasma frequency and the spectrum was found to be centered about this value. These results, along with polarization studies showing the wave electric field to be field aligned, are consistent with the interpretation of the waves as electron plasma oscillations.

Crawford, G. K.↗

A numerical study of thunderstorm electrification - Model development and case study

A numerical model was developed for examining the thunderstorm electrification process in which it is assumed that the electrification is entirely due to noninductive charge transfer between colliding ice crystals and hail. Since this ice-hail charge mechanism is very dependent on particle sizes and distributions, an explicit microphysical framework is used. To maintain simplicity, the electrification model is kinematic; thus the temperature and velocity fields are input into the electrification model. The cloud model of Taylor (1989) was used to generate the temperature and velocity fields to examine the July 19, 1981, Cooperative Convective Precipitation Experiment thundercloud. Using these fields, the electrification model produced time-dependent ice particle concentrations, radar reflectivities, charge, and vertical electric field distributions in good general agreement with those observed. The model produced a maximum electric field strength of 1.27 kV/cm, which is on the order of that needed for lightning initiation, and this maximum occurred very close to the time of the observed discharge. Thus, the ice-hail charge mechanism appears to have played an important role in the electrical development of the July 19 cloud.

Norville, K.↗

A wind tunnel investigation of the shape of uncharged raindrops in the presence of an external, electric field

Results of a wind tunnel experiment in which electrically uncharged water drops of 500 to 3000 microns equivalent radius are freely suspended in the vertical air stream of the UCLA cloud tunnel are presented. During this suspension the drops were exposed to external vertical electric fields of 500 to 8,000 volts/cm. The change in drop shape with drop size and electric field strength was noted and is discussed in the light of theoretical work cited in the literature which unfortunately does not take into account the effects of air flow past the drop. The wind tunnel study is documented by stills from a 16 mm film record that demonstrates the shape of water drops in response to both hydrodynamic and electric forces.

Pruppacher, H. R.↗

RF Exposure Analysis for Multiple Wi-Fi Devices In Enclosed Environment

Wi-Fi devices operated inside a metallic enclosure have been investigation in the recent years. A motivation for this study is to investigate wave propagation inside an enclosed environment such as elevator, car, aircraft, and spacecraft. There are performances and safety concerned that when the RF transmitters are used in the metallic enclosed environments. In this paper, the field distributions inside a confined room were investigated with multiple portable Wi-Fi devices. Computer simulations were performed using the rigorous computational electromagnetics (CEM). The method of moments (MoM) was used to model the mutual coupling among antennas. The geometrical theory of diffraction (GTD) was applied for the multiple reflections off the ground and walls. The prediction of the field distribution inside such environment is useful for the planning and deployment of a wireless radio and sensor system. Factors that affect the field strengths and distributions of radio waves in confined space were analyzed. The results could be used to evaluate the RF exposure safety in confined environment. By comparing the field distributions for various scenarios, it was observed that the Wi-Fi device counts, spacing and relative locations in the room are important factors in such environments. The RF Keep Out Zone (KOZ), where the electric field strengths exceed the permissible RF exposure limit, could be used to assess the RF human exposure compliance. As shown in this study, it s possible to maximize or minimize field intensity in specific area by arranging the Wi-Fi devices as a function of the relative location and spacing in a calculated manner.

Hwu, Shian U.↗

Evaluation of The Performance of The Mars Environmental Compatibility Assessment Electrometer

The Mars Environmental Compatibility Assessment (MECA) electrometer is an instrument that was designed jointly by researchers at the Jet Propulsion Laboratory and the Kennedy Space Center, and is intended to fly on a future space exploration mission of the surface of Mars. The electrometer was designed primarily to study (1) the electrostatic interaction between the Martian soil and five different types of insulators, which are attached to the electrometer, as the electrometer is rubbed over the Martian soil. The MECA/Electrometer is also capable of measuring (2) the presence of charged particles in the Martian atmosphere, (3) the local electric field strength, and (4) the local temperature. The goal of the research project described in this report was to test and evaluate the measurement capabilities of the MECA/Electrometer under simulated Martian surface conditions using facilities located in the Labs and Testbeds Division at the Kennedy Space Center. The results of this study indicate that the Martian soil simulant can triboelectrically charge up the insulator surface. However, the maximum charge buildup did not exceed 18% of the electrometer's full-range sensitivity when rubbed vigorously, and is more likely to be as low as 1% of the maximum range when rubbed through soil. This indicates that the overall gain of the MECA/Electrometer could be increased by a factor of 50 if measurements at the 50% level of full-range sensitivity are desired. The ion gauge, which detects the presence of charged particles, was also evaluated over a pressure range from 10 to 400 Torr (13 to 533 mbar). The electric field sensor was also evaluated. Although the temperature sensor was not evaluated due to project time constraints, it was previously reported to work properly.

Mantovani, James G.↗

Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer

The Mars Environmental Compatibility Assessment (MECA) electrometer is an instrument that was designed jointly by researchers at the Jet Propulsion Laboratory and the Kennedy Space Center, and is intended to fly on a future space exploration mission of the surface of Mars. The electrometer was designed primarily to study (1) the electrostatic interaction between the Martian soil and five different types of insulators, which are attached to the electrometer, as the electrometer is rubbed over the Martian soil. The MECA/Electrometer is also capable of measuring (2) the presence of charged particles in the Martian atmosphere, (3) the local electric field strength, and (4) the local temperature. The goal of the research project described in this report was to test and evaluate the measurement capabilities of the MECA/Electrometer under simulated Martian surface conditions using facilities located in the Labs and Testbeds Division at the Kennedy Space Center. The results of this study indicate that the Martian soil simulant can triboelectrically charge up the insulator surface. However, the maximum charge buildup did not exceed 18% of the electrometer's full-range sensitivity when rubbed vigorously, and is more likely to be as low as 1% of the maximum range when rubbed through soil. This indicates that the overall gain of the MECA/Electrometer could be increased by a factor of 50 if measurements at the 50% level of full-range sensitivity are desired. The ion gauge, which detects the presence of charged particles, was also evaluated over a pressure range from 10 to 400 Torr (13 to 533 mbar). The electric field sensor was also evaluated. Although the temperature sensor was not evaluated due to project time constraints, it was previously reported to work properly.

Mantovani, James G.↗

Orbiter environment at S- and Ku-band frequencies

Detailed measurements of the electric field strength associated with the Ku-band radar and S-band communication link were made by the Plasma Diagnostics Package (PDP) on STS 51F. These measurements were made while the PDP was attached to the Remote Manipulation System arm and again while the PDP was released as a subsatellite. The results indicate that cargo elements that remain inside of the scan limits of the radar should experience fields less than 2 V/m and that elements that may encounter the main beam can use 300 V/m as a design guideline with adequate safety margin. S-band fields tended to be several dB lower than worst-case predictions. Safe design practice indicates that an electric field E = 100/r (r in meters) should be used as a guideline for deployable systems. S-band electric fields within the cargo bay envelope should be less than 2 V/m even with edge diffraction effects and reflections from other payloads taken into account. The absolute accuracy of these measurements is about 2 dB.

Murphy, G. B.↗