Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC INSPECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PNF Modulator, PNF Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipelines, circuits, and conduits. Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

TEV-3349 "ATF-2 2A Loop Pin Cladding Requirements"

Industry partners, including Westinghouse, Framatome, General Electric, General Atomics, Toshiba, etc. require requirements for fuel pins they insert in the reactor for testing. This document contains those requirements. These requirements represent an agreement between ATR and NS&T, and include the requirements for pins fabricated at the INL. These include inspections such as radiography, helium leak check, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nondestructive Evaluation (NDE) of Cable Moisture Exposure using Frequency Domain Reflectometry (FDR)

This Pacific Northwest National Laboratory (PNNL) milestone report assesses the capability of frequency domain reflectometry (FDR) to determine electrical cable submergence using PNNL’s Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable/motor test bed. This work includes a review of relevant literature as well as experimental tests. Nuclear power facilities have experienced various electrical cable failures related to water exposure. The current industry response involves actions to de-water cable vaults, manholes, and other cable locations. These efforts require considerable expenditure of resources, which makes it desirable for the industry to have information on cable condition and history regarding their submergence and water exposure (Mantey 2012). Two tests that are gaining favor within the nuclear industry are time-domain reflectometry (TDR) and FDR. These are low-voltage nondestructive tests that can be applied at a cable end. Testing from the cable end is important because local inspection along the cable length is very difficult due to cables being routed within trays, conduits, underground, and through walls. Both TDR and FDR techniques have been shown to locate cable insulation damage due to thermal, radiation, and mechanical damage. FDR measurements are also more sensitive than TDR to temperature changes, low-bend radius bends, and cable contact with various materials, including conductive materials like steel and water. This work evaluates the feasibility to extend FDR testing to characterizing whether an electrical cable is submerged or not and where it may be submerged using PNNL’s ARENA cable/motor test bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

Investigate the Security of Electric Vehicle (EV) Ecosystem Applications

Apps that run on mobile devices are one of critical components of the electric vehicle (EV) ecosystem and pose possible threat actor points of entry that may impact the trust and security of EV charging systems in the future. Mobile apps often rely on communication between cloud servers and users, thereby creating potential points of entry for cyberattacks. Although app stores such as Apple App Store or Google Play Store generally test the security of apps, the cyber aspects may not be sufficient for many entities including DOD, federal fleets, and commercial entities. A more thorough inspection and the ability to influence developers is imminently needed. This research studies security attributes and vulnerabilities of a sample of mobile applications that support key user functions in the EV ecosystem. The study shows that all analyzed apps have security risks, categorized as either high or medium or both and a comprehensive cybersecurity guideline for developing mobile apps is necessary.

33 ADVANCED PROPULSION SYSTEMS↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipe lines, circuits, conduits. In addition, high voltage and flowing fluids are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

High-Temperature Particle Heat Exchanger for sCO2 Power Cycles [Award 30342]

This report describes the design, development, and testing of a prototype 100 kWt particle-to-supercritical CO 2 (sCO2) heat exchanger. An analytic hierarchy process was implemented to compare and evaluate alternative heat-exchanger designs (fluidized bed, shell-and-plate moving packed bed, and shell-and-tube moving packed bed) that could meet the high pressure (≥ 20 MPa) and high temperature (≥ 700 °C) operational requirements associated with sCO2 power cycles. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. A 100 kWt shell-and-plate design was selected for construction and integration with Sandia’s falling particle receiver system that heats the particles using concentrated sunlight. Sandia worked with industry to design and construct the moving packed-bed shell-and-plate heat exchanger. Tests were performed to evaluate its performance using both electrical heating and concentrated sunlight to heat the particles. Overall heat transfer coefficients at off-design conditions (reduced operating temperatures and only three stainless steel banks in the counter-crossflow heat exchanger) were measured to be approximately ~25 - 70 W/m 2 -K, significantly lower than simulated values of >100 W/m 2 -K. Tests using the falling particle receiver to heat the particles with concentrated sunlight yielded overall heat transfer coefficients of ~35 – 80 W/m 2 -K with four banks (including a nickel-alloy bank above the three stainless steel banks). The overall heat transfer coefficient was observed to decrease with increasing particle inlet temperatures, which contrasted the results of simulations that showed an increase in heat transfer coefficient with temperature due to increased effective particle-bed thermal conductivity from radiation. The likely cause of the discrepancy was particle-flow maldistributions and funnel flow within the heat exchanger caused by internal ledges and cross-bracing, which could have been exacerbated by increased particle-wall friction at higher temperatures. Additional heat loss at higher temperatures may also contribute to a lower overall heat-transfer coefficient. Design challenges including pressure drop, particle and sCO2 flow maldistribution, and reduced heat transfer coefficient are discussed with approaches for mitigation in future designs. Lessons learned regarding instrumentation, performance characterization, and operation of particle components and sCO2 flow loops are also discussed. Finally, a 200 MWt commercial-scale shell-and-plate heat-exchanger design based on the concepts investigated in this report is proposed.

14 SOLAR ENERGY↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Vitrification of High-Cr Glass in Research-Scale Melter

This test report describes the experimental results from a small-scale test using the research-scale melter (RSM) at Pacific Northwest National Laboratory to demonstrate processing of a high-Cr simulated feed stream, designated HLW-HCr-16. The RSM is a small, joule-heated melter capable of processing melter feed continuously. The melter is equipped with Inconel ® 693 electrodes, Monofrax ® K-3 refractory, and an Inconel 690 pour spout. An electric kiln surrounds the melter body and minimizes heat loss from the melter body during operation. The RSM is equipped with an offgas treatment system that employs quenching, wet scrubbing, and high-efficiency mist elimination. The glass-discharge section is heated to facilitate pouring of the glass. The melter is fitted with a melt cavity that is ~25 cm (10 in.) in diameter with a nominal glass depth of 8.9 cm (3.5 in.). The melter was operated with a target glass temperature of 1150°C and target plenum temperature between 550°C and 700°C for this test. The air bubbling rate was 4.2 L/min. Overall, during the continuous operation of the melter for ~ 103 hours, ~ 141 kg of glass was produced. At the conclusion of the test, the melter and exhaust lines were visually inspected for particulate deposition and corrosion. Entrained material had adhered to the underside of the melter lid and to the exhaust piping. Enrichments in elements such as Cl, F, B, K, Li, P, Na, and S were measured in these deposits through inductively coupled plasma–optical emission spectroscopy and X-ray fluorescence analysis. When the melter electrodes and air bubbler tube were removed from the glass in the RSM, the electrodes appeared discolored, but no significant loss of metal was observed. The processing of a high-Cr simulant, HLW-HCr-16, in the RSM produced glass at an average rate of 1.36 kg/h, equaling a melter-surface-area normalized glass generation rate of 654 kg/day/m 2 . The resulting glass met the toxicity characteristic leaching procedure requirement. Test results of crystallinity, electrical conductivity, and viscosity showed good processing properties of this high-Cr high-level waste glass. RSM offgas was also sampled and analyzed at periodic intervals during steady-state operating conditions. The total decontamination factor averaged by four sampling periods was 134. The concentrations of CO and NO x in emissions were 237 to 422 and 69 to 94 parts per million by volume, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of glass forming additives on low-activity waste feed conversion to glass

A significant effort was invested in the past to develop and refine mathematical models that relate the composition of nuclear waste glasses with their properties, such as viscosity, electrical conductivity, or chemical durability. However, less attention has been paid to the formulation of the melter feed itself, such as the chemical form and the particle size of the glass forming and modifying additives (GFMA), which have a significant effect on the feed-to-glass conversion process during melting. To address this issue, we systematically changed the mineral composition of a simulated low-activity waste melter feed and inspected its melting behavior. When substituting minerals with corresponding oxides and hydroxides, we found that different alumina sources (kyanite, gibbsite, boehmite, or corundum) had the strongest effect on the feed melting process, whereas the sources of Ca, Mg, and Zr had little effect. Further, the x-ray diffraction analysis showed that the alumina sources differ in their dissolution kinetics: early dissolving alumina sources, such as gibbsite (Al(OH) 3 ) and boehmite (AlO(OH)), increase the transient glass-forming melt viscosity at early stages, when gases still evolve, causing extended foaming, whereas alumina sources that dissolve at high temperatures, such as kyanite (Al 2 SiO 5 ) and corundum (Al 2 O 3 ), keep the transient glass-forming melt viscosity low and lead to a faster foam collapse. Using viscosity-composition relationship to estimate the viscosity of transient glass-forming melts in the primary foaming range, we found that the primary foam began to collapse at 360 to 800 Pa s, and fully collapsed between 65 and 260 Pa s. This result agrees with our previous studies, according to which the glass-forming melt viscosity at the cold cap foam bottom ranged from 24 to 85 Pa s.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maritime Fuel Cell Generator Project: 2018 – 2023

This report summarizes activity in the Maritime Fuel Cell (MarFC) Generator Project from 2018 – 2023. FY 2018 saw the implementation of upgrades and repairs, making the unit more reliable and operator friendly. In FY2019 the team engaged the Scripps Institution of Oceanography (SIO) to use the MarFC to provide zero-emission shore power to the research vessel R/V Robert Gordon Sproul while in port at the Nimitz Marine Facility in San Diego, CA. In FY2020, the MarFC unit was shipped to San Diego, CA. A fueling contract with IGX was established to support MarFC operations at SIO, with renewable hydrogen provided by the California State University Los Angeles (CSULA) hydrogen station. The project team (Sandia, Cummins/Hydrogenics) provided training to SIO staff on the technical details of the MarFC, the safe use of hydrogen in general and the MarFC in particular. The first fueling of the unit at the SIO pier was successfully completed by IGX. The first powering of a vessel with fuel-cell shore power was conducted with the R/V Robert Gordon Sproul. While the mechanical systems (lights, AC, ventilation, hydraulics, pumps and cranes) were powered without incident, problems arose when powering the computer systems. Inspections carried out in FY2021 revealed the MarFC needed routine maintenance. Maintenance was performed and the unit was upgraded. The MarFC was turned on after the year pause, and initial test data on power levels and stability were collected. FY2022 was a year spent repairing, upgrading and testing the MarFC unit. Spikes in power and voltage were observed above 60 kW that could potentially extend below 60 kW with time. Such spikes could cause problems with the Sproul electrical systems. These age-related problems, the extended time for the Sproul spent in dry dock for scheduled upgrades, and the associated need to reschedule the vessel’s high-priority science missions made it no longer possible to deploy the unit at SIO. After due consideration, the decision was made by DOE, MARAD and the project team to cease the deployment, remove the MarFC from SIO, and not pursue further deployment activities. On December 2, 2022, the MarFC unit was removed from the Scripps Nimitz Marine Facility and shipped to Fridley, Michigan. The Cummins/Hydrogenics plan for the unit is to assess the condition of the MarFC subcomponents, and then use it as a training/learning system for technical employees new to hydrogen fuel-cell technology. After summarizing project activity from 2018 – 2023, this report provides a review of lessons learned. This report provides next steps in contemplating a follow-on project that would further advance the use of fuel-cell-based shore power in a marine setting. A comparison is made of the project results to the original objectives. This report ends with an accounting of presentations stemming from the project, and a list of references.

08 HYDROGEN↗

Evaluating the Lightning Strike Damage Tolerance for CFRP Composite Laminates Containing Conductive Nanofillers

Conductive nanofillers, such as carbon nanotube, graphene nanoplatelets, and carbon black particles (with diameters in nanometers) have been shown to enhance the electrical conductivity of fiber reinforced polymer matrix composites in many existing studies. The motivation is primarily for lightning strike protection, electromagnetic interference shielding, de-icing, and the manufacturing of lightweight electronic components. Here, we evaluate the lightning strike damage tolerance of carbon fiber reinforced polymer (CFRP) matrix composite laminates containing conductive nanofillers with varying weight fractions, including carbon black (CB), carbon nanotubes (CNT), and a mix of CB and CNT, through simulated lightning strike tests, followed by both non-destructive ultrasonic inspection and destructive sectioning to characterize the damage inflicted by the simulated lightning strike. Three-point flexural tests are performed to evaluate the residual strength retained by all CFRP specimens. Results show that lightning strike damage experienced varying levels of reduction for CFRP composite specimens containing conductive fillers in comparison to the baseline specimen without fillers. Notably, the delamination only penetrated to the interface between the 1st and 2nd layer for the specimen with 0.25 wt.% CNT in comparison to the baseline CFRP specimen for which the delamination penetrated to the interface between the 5th and 6th layer. Moreover, the retention of the flexural modulus increased from 26.5% to a maximum of 95.0% for the specimen with 0.25 wt.% hybrid CB and CNT. Yet, we show that using our chosen conductive fillers cannot fully eliminate lightning strike damage. Additionally, adding conductive fillers could compromise the flexural properties. We provide discussions on future recommendations on using conductive fillers for the lightning strike protection of CFRP composites.

36 MATERIALS SCIENCE↗

Manufacturing and Hydro Testing of a 10 MWe sCO2 Axial Turbine

Abstract Supercritical CO2 (sCO2) power cycles designed for thermodynamic efficiencies above 50% push component designs into pressure and temperature combinations that approach the limits of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Piping Design Codes with Turbine inlet conditions near 250 bar and 715 °C. These design conditions which limit available materials to high nickel alloys are compounded by the high fluid densities of sCO2 at these conditions which result in very compact machinery at the 10 MWe class which are currently being developed for the DOE supercritical transformational electric power (STEP) program. Design of the STEP Turbine is complete with integrated lessons learned from a previous 1 MWth subscale demonstration of a high temperature 10 MWe Turbine designed under the DOE SunShot Program. Fabrication of the STEP Turbine is nearing completion with all housings and pressure containing components in hand. This paper provides a detailed look at design intentions and limitations for the pressurized sections of the main pressure casing and the fabrication of key turbine components. Additional discussion is provided regarding postfabrication inspection and acceptance of the casing for use after issues with casing welds were identified late in the fabrication process.

Engineering↗

Mechanical Characterization of the NIF Ignition Target TMPSA Bonding Flexure

The Thermo-Mechanical Package Sub-Assembly (TMPSA) provides a critical mechanical, thermal, and electrical interface between a silicon arm and a TMP aluminum can in a NIF ignition target. During assembly, sixteen silicon pads are bonded to the aluminum using a fixture that positions the components and applies a repeatable prescribed displacement through a compliant flexure. The flexure converts fixture interference into displacement and reaction force. Because bondline thickness variation must be maintained within +/-4 µm, consistent flexure behavior is important to the assembly process. With a recent string of TMPSAs exhibiting low bond strength, the flexures were inspected. Despite being manufactured to the same specifications, flexures were found to exhibit variation in measured stiffness. Additionally, the measured stiffness values did not always follow the presumed beam mechanics model. This work addresses two questions: whether the bonding fixture is working as intended, and whether the previously made stiffness measurements are accurate representations of the use case. The flexures are analyzed using Euler-Bernoulli beam theory, measured beam dimensions, finite element analysis, and tolerance stack-up calculations. The analysis shows that the fixed-guided beam mechanics model appropriately represents the flexure during TMPSA bonding, but the chisel-tip stiffness measurement method introduces a deformation to the inner ring of the flexure that is not represented during use. The measured stiffness values should therefore be interpreted as test-condition stiffness values rather than direct measurements of operational flexure stiffness. The discrepancy is therefore attributed primarily to the measurement boundary condition rather than to failure of the fixed-guided beam model. Recommendations are provided for GD&T, dimensional inspection, and a representative stiffness testing method to better control bondline variation.

42 ENGINEERING↗

A Nonorthogonal Configuration Interaction Approach to Singlet Fission in Perylenediimide Compounds

Perylenediimide molecules constitute a family of chromophores that undergo singlet fission, a process in which an excited singlet state converts into lower energy triplets on two neighboring molecules, potentially increasing the efficiency of organic solar cells. Here, the nonorthogonal configuration interaction method is applied to study the effect of the different crystal packing of various perylenediimide derivatives on the relative energies of the singlet and triplet states, the intermolecular electronic couplings, and the relative rates for singlet fission. The analysis of the wave functions and electronic couplings reveals that charge transfer states play an important role in the singlet fission mechanism. Dimer conformations where the PDI molecules are at large displacements along the long axis and short on the short axis are posed as the most favorable for singlet fission. The role of the substituent at the imide group has been inspected concluding that, although it has no effect in the energies, for some conformations it significantly influences the electronic couplings, and therefore, replacing this substituent with hydrogen may introduce artifacts in the computational modeling of the PDI molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗