Search NASASearch

SEARCH · Search NASA

Results for “ELECTROMAGNETIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sorbent Regeneration via Radiofrequency-Assisted Dielectric Heating for Direct Air Capture of CO 2

Direct air capture (DAC) of CO 2 is a negative emission technology that utilizes sorbents requiring a regeneration step for repeated ab(/d)sorption–desorption cycles. Here we report an unconventional approach to desorb captured CO 2 from a porous sorbent using radiofrequency (RF) irradiation for dielectric heating and targeted energy transfer, thus enabling modularity and promoting renewable energy input. Regeneration of composites of functional ionic liquid and metal–organic framework with high CO 2 capacity and enhanced transport is demonstrated under conditions relevant to DAC. RF-assisted dielectric heating at the megahertz frequency range shows effective absorption of electromagnetic energy and consequently rapid release of the captured CO 2 .

Ionic liquids

Aluminum Based Solvent-Free Organic–Inorganic Hybrid Materials

In emerging materials, molecular hybrids are especially promising, as they have molecular level mixing of the organic and inorganic components, producing homogeneous materials without interfaces that can deteriorate properties. However, the current methods of manufacturing molecular hybrids are based on solution processing, which is impractical for bulk materials such as may be used for optically clear radiation and electromagnetic shielding components or photonics. Here we examine molecular hybrids composed of aluminum isopropoxide (AIP) and epoxy resins aiming to understand the molecular scale chemistry and manufacturability of these hybrid materials. DSCmonitored cure revealed the ideal cure temperature for these materials is 160−170 °C and demonstrated that an AIP concentration of 16.7 wt % maximizes the extent of reaction. Kinetic analysis of the curing reaction showed the Sestak−Berggren autocatalytic model is effective at temperatures over 140 °C but the reaction has diffusion limitations at a temperature of 120 °C. Mechanical testing with custom resin molds revealed a decrease in properties of the bulk samples with increasing AIP content due to an increase in defects but further testing with nanoindentation demonstrated comparable or improved mechanical properties of AIP-epoxy hybrids compared to epoxy resin with a standard hardener. Ultimately, this work lays the foundation for hardener-free epoxy-aluminum inorganic/organic hybrids and presents opportunities to expand on properties for specific applications such as thermal conductivity, optical clarity, and dielectric constant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Dual-Wavelength Simultaneous Patterning of Degradable Thermoset Supports for One-Pot Embedded 3D Printing

Vat photopolymerization (VP) techniques have enabled the fabrication of complex geometries while balancing high precision and fast processing times. 3D printed objects are traditionally built layer-by-layer with newly cured layers being structurally supported by previous ones. Fabricating unsupported features such as overhangs and arches risks misalignment and sagging, limiting the range of accessible designs. To overcome this issue, support structures are fabricated along with the primary object as temporary scaffolds that provide stability and conserve print fidelity. For VP specifically, patterning dissolvable sacrificial supports is attractive to avoid manual removal after printing. In this study, we demonstrate a base-degradable thermoset to pattern print supports in a one-pot formulation along with the primary structural material. Efficient printing is enabled using a dual-wavelength negative imaging (DWNI) DLP printer that patterns the degradable thermoset with visible light and the permanent network with UV light, which are simultaneously projected using a single digital micromirror device (DMD). Printed objects undergo thermal postprocessing to enhance the final conversion of the primary material, after which thermoset supports are degraded in a basic, aqueous solution. This approach provides a robust method for the dual-wavelength patterning of sacrificial thermoset supports, broadening the range of accessible 3D printable materials and geometries.

3D printing

Technoeconomic Analysis of a Novel Microwave Process to Produce Ethylene from Methane

Ethylene is a critical feedstock in industrial processes, serving as a raw material in the petrochemical industry to produce plastics and commodity chemicals. Conventional ethylene production routes are energy-intensive and contribute substantially to the carbon footprint of chemical manufacturing. In this study, an industrial-scale novel microwave process was simulated using ASPEN Plus to assess its economic viability. Technoeconomic analysis confirmed the economic competitiveness of the novel microwave process, with a levelized cost of ethylene of USD 0.51/kg compared to USD 0.56/kg for the conventional base case. Key economic drivers of the process were identified, and sensitivity analyses were conducted to evaluate their impact on project economics. Furthermore, 87.7% of the total utility consumption in the novel microwave process is electricity, highlighting its potential to contribute to the electrification of the chemical industry. The findings of this study confirm the economic feasibility of both industrial-scale microwave reactors and modular plant configurations for the production of ethylene from methane, offering a promising alternative to conventional processes.

electromagnetic radiation

Mechanistic Investigation of the Ce(III) Chloride Photoredox Catalysis System: Understanding the Role of Alcohols as Additives

Photocatalytic C–H activation is an emerging area of research. While cerium chloride photocatalysts have been extensively studied, the role of alcohol additives in these systems remains a subject of ongoing discussion. It was demonstrated that the photocatalyst [NEt 4 ] 2 [Ce IV Cl 6 ] ( 1 ) produces •Cl and added alcohols exhibit zero-order kinetics. Prior studies by other researchers suggested that 1 and alcohols lead to cerium alkoxide [Ce–OR] and alkoxy radical intermediates. Here, to understand these seemingly divergent mechanistic proposals, an expanded investigation comparing cerium(IV) catalyst 1 and cerium(III) complex [NEt 4 ] 3 [Ce III Cl 6 ] ( 2 ), which exhibit markedly different reactivity and C–H selectivity, is disclosed. Our findings reveal that alcohol additives accelerate the conversion of cerium(III) to cerium(IV) catalysts, forming key intermediates such as [NEt 4 ] 2 [Ce III Cl 5 (HOCH 3 )] ( 5 ) and [NEt 4 ] 2 [Ce IV Cl 5 (OCH 3 )] ( 6 ), driven by excited-state di-tert-butyl azodicarboxylate under blue light irradiation. The active complex 6 releases the •OCH 3 radical, in sharp contrast to •Cl radicals initiated by cerium(IV) photoredox catalyst 1 . These different reactivity and selectivity profiles can be understood in the context of complex 5 generation and in situ formation of base to afford complex 6 . Experimental validation shows enhanced selectivity toward C–H bonds with different reactivity with catalyst 1 and methanol upon the addition of base and decreased selectivity with catalyst 2 and methanol upon the addition of acid. These findings unify the previously contrasting observations of cerium halide/alkoxide photocatalytic systems and provide a comprehensive understanding on the essential role of base/acid and alcohol in selectivity and reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Excessive charge, beam loading, and impedance collapse thresholds for a velvet emitter

Excess emission has been observed from velvet cathodes with total emission times >150 ns. In this diode experiment, we produce a sub-relativistic electron beam with the ability to consistently change γ from 1.2 to 1.5 and β = 0.5–0.75. Electron emission in this particular diode geometry requires electric fields >40 kV/cm. The current increases at steady rates >0.05 A/ns after the head of the pulse, indicating an expansion of the emission surface and reduction in the effective AK gap. Small transients of excess emission (or arcs) are consistently observed for current pulses exceeding 150 ns. The excess emission results in beam loaded levels ≥10 kV on the diode voltage. The effects described here are compounded as diode voltage is increased. The principal objective of these experiments is to quantify electric field emission thresholds, current ramps, excess emission delays, effective beam loading, and impedance collapse.

43 PARTICLE ACCELERATORS

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background

New Probe of Cosmic Birefringence Using Galaxy Polarization and Shapes

We propose a novel statistical method to measure cosmic birefringence and demonstrate its power in probing parity violation due to axions. Exploiting an empirical correlation between the integrated radio polarization direction of a spiral galaxy and its apparent shape, we devise an unbiased minimum-variance estimator for the rotation angle, which should achieve an uncertainty of 5°–15° per galaxy. In conclusion, large galaxy samples from the forthcoming SKA continuum surveys, together with optical shape catalogs, promise a comparable or even lower noise power spectrum for the rotation angle than in the CMB Stage-IV (CMB-S4) experiment, with different systematics.

Axion-like particles

Cosmic structure strikes back: The elimination of vector-mediated nonstandard interaction models as a mechanism for sterile neutrino dark matter production

We revisit sterile neutrino production enabled by nonstandard interactions (NSIs) among active neutrinos mediated by new bosons. We focus on vector mediators, including neutrinophilic, gauged 𝐿 𝜇 −𝐿 𝜏 , and 𝐵−𝐿 realizations, that modify in-medium dispersion and scattering, thereby altering the active-sterile conversion history. Building on a novel production framework with NSI thermal potentials and collision integrals, we compute nonthermal phase-space distributions across sterile neutrino mixing and NSI parameters and map each point to an equivalent thermal warm dark matter particle mass 𝑚 th via linear theory transfer function fitting with the cosmological structure formation Boltzmann solver. This enables a direct reinterpretation of state-of-the-art structure formation limits from Milky Way satellites, strong lensing, and the Lyman-𝛼 forest. These limits, in conjunction with x-ray decay searches, as well as results from a wide variety of particle physics experiments allow for a more complete examination of these models. We find that these vector-mediated models are ruled out when the full combination of current constraints, listed above, are taken into account. NSI scalar-mediated models and models with low reheating temperatures remain viable.

cosmology

Relativistic gas accretion onto supermassive black hole binaries from inspiral through merger

Accreting supermassive black hole binaries are powerful multimessenger sources emitting both gravitational and electromagnetic (EM) radiation. Understanding the accretion dynamics of these systems and predicting their distinctive EM signals is crucial to informing and guiding upcoming efforts aimed at detecting gravitational waves produced by these binaries. To this end, accurate numerical modeling is required to describe both the spacetime and the magnetized gas around the black holes. In this paper, we present two key advances in this field of research. First, we have developed a novel 3D general relativistic magnetohydrodynamics (GRMHD) framework that combines multiple numerical codes to simulate the inspiral and merger of supermassive black hole binaries starting from realistic initial data and running all the way through merger. Throughout the evolution, we adopt a simple but functional prescription to account for gas cooling through photon emission. Next, we have applied our new computational method to follow the time evolution of a circular, equal-mass, nonspinning black hole binary for ∼200 orbits, starting from a separation of 20⁢𝑟 𝑔 and reaching the postmerger evolutionary stage of the system. We have shown how mass continues to flow toward the binary even after the binary “decouples” from its surrounding disk, but the accretion rate onto the black holes diminishes. We have identified how the minidisks orbiting each black hole are slowly drained and eventually dissolve as the binary compresses. We confirm previous findings that the system’s luminosity decreases by a factor of a few during inspiral; however, we observe an abrupt increase by ∼50% in this quantity at the time of merger, likely accompanied by an equally abrupt change in spectrum. Lastly, we have demonstrated that during the inspiral, fluid ram pressure regulates the fraction of the magnetic flux transported to the binary that attaches to the black holes’ horizons.

Accretion disk & black-hole plasma