UV photon counting detectors for high-altitude balloon and sounding rocket experiments

We report on development of ultraviolet photon counting detectors based on the 2D-doped and atomic layer deposition (ALD) custom coated electron multiplying CCD (EMCCDs) and their deployment in a high-altitude balloon experiment Faint Intergalactic-medium Redshifted Emission Balloon (FIREBall)-2 that was launched on September 22, 2018. The detector quantum efficiency (QE) was optimized for the narrow stratospheric window of a balloon at 200 - 225 nm.

Jones, Todd J.↗

The Roman Space Telescope Coronagraph Technology Demonstration: Current Status and Relevance to Future Missions

The Nancy Grace Roman Space Telescope (formally WFIRST) will be launched in the mid-2020’s with an onboard coronagraph instrument which will serve as a technology demonstrator for exoplanet direct imaging. The Roman Coronagraph will be capable of detecting and characterizing exoplanets and circumstellar disks in visible light at an unprecedented contrast level of ~10-8 or lower. Such a contrast level, which is several magnitudes better than state-of-the-art visible or near-infrared coronagraphs, raises entirely new challenges that will be overcome using a combination of hardware, calibration and data processing. In particular, the Roman Coronagraph will be the first space-based coronagraphic instrument with real-time active wavefront control through the use of large format deformable mirrors, and its EMCCD detector will enable faint signal detection in photon-counting mode. The Roman Coronagraph passed its critical design review successfully in April 2021, and is now well on its path to demonstrate many core technologies at the levels required for future exo-Earth direct imaging missions.

Luchik, T.↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in large transonic and supersonic wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and lightly seeded air to determine the viability and accuracy of the technique. The other reality of a wind tunnel setup is the background scattering or the glare at laser frequency, which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. Since the background glare occurs at the known frequency of the incident light and the Mie scattering peak corresponds to the Doppler shift from the bulk velocity, both were easily identified, and provided a measure of flow velocity. Preliminary results show that the Rayleigh spectrum can also be resolved, which provides a measure of temperature. It is observed that a slight drift of the laser frequency during data collection affected fitting of the model function leading to larger error. A feedback loop-based stabilization system is on development to take advantage of slight tunability of the laser via a piezo-control. Preliminary results are presented in the abstract. More extensive data from a systematic survey will be presented in the final paper.

Rayleigh scattering↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in high-speed wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and air with different particle concentration to determine the accuracy of the technique. The other reality of a wind tunnel setup is the spurious reflection and scattering of the incident laser beam by solid surfaces (flare light), which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light from a point on the laser path is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. It was observed that the present modeling approach can extract velocity and temperature with reasonable accuracy when the intensity of the Mie scattered light is less than or comparable to that of the Rayleigh scattered light; beyond that error in velocity measurement remains reasonable ±12m/s but the temperature measurement becomes progressively more inaccurate. Increasingly the flare light is found to cause a bias error in velocity. Similar trend is observed in the presence of both the flare light and the Mie scattered light. The setup has provided a set of data for the future improvement of the modeling procedure, and demonstrated that even in the case of large amount of dust particles and large flare light the present technique can provide measurement of velocity with reasonable accuracy.

Rayleigh scattering↗

HyperMic

HyperMic is the control software for the Hyperspectral Confocal Microscope, and is required for the use of the microscope. It interfaces with, and controls the main subsystems of the microscope including the EMCCD detector, the video camera, the XYZ stage system, the optical shutters, the filter wheels, and the illumination sources. It allows the user to select regions to image, and acquire and save hyperspectral images. HyperMic is capable of acquiring single (2-dimensional) image frames or full 3-dimensional image stacks.

Sinclair, Michael 8↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A review of quantum imaging methods and enabling technologies

The field of quantum imaging has recently seen an explosion of new methods and techniques. At the heart of most quantum imaging approaches are three enabling technologies: the source of the quantum light, the detectors that turn sensing into imaging, and the method by which the quantum nature of light is leveraged to improve the desired measurement. This review addresses the dominant and emerging technologies in each of these components as well as details concerning the implementations of various quantum imaging methods.

36 MATERIALS SCIENCE↗

New characterization techniques for LSST sensors

Fully depleted, thick CCDs with extended infra-red response have become the sensor of choice for modern sky surveys. The charge transport effects in the silicon and associated astrometric distortions could make mapping between the sky coordinates and sensor coordinates non-trivial, and limit the ultimate precision achievable with these sensors. Two new characterization techniques for the CCDs, which both could probe these issues, are discussed: x-ray flat fielding and imaging of pinhole arrays.

Si-PMTs↗

Characterising CCDs with cosmic rays

The properties of cosmic ray muons make them a useful probe for measuring the properties of thick, fully depleted CCD sensors. The known energy deposition per unit length allows measurement of the gain of the sensor's amplifiers, whilst the straightness of the tracks allows for a crude assessment of the static lateral electric fields at the sensor's edges. The small volume in which the muons deposit their energy allows measurement of the contribution to the PSF from the diffusion of charge as it drifts across the sensor. In this work we present a validation of the cosmic ray gain measurement technique by comparing with radioisotope gain measurments, and calculate the charge diffusion coefficient for prototype LSST sensors.

79 ASTRONOMY AND ASTROPHYSICS↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automated system to measure the quantum efficiency of CCDs for astronomy

We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic component of the LSST camera.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of the CCD development for the Dark Energy Spectroscopic Instrument

We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)(2)-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fringing in MonoCam Y4 filter images

Here, we study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net "fringe" pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relative intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. Lastly, we also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of silicon photomultiplier performance in external electric fields

In this paper, we report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149 K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No visible damage to the surface of the devices was caused by the exposure.

Noble liquid detectors (scintillation, ionization,↗

Silicon photomultipliers radiation damage and recovery via high temperature annealing

The performance of Silicon Photomultipliers (SiPMs) from several vendors are characterized before and after exposure of up to 10 10 neutron/cm 2 dosage. Collectively, we firmly established that the typical orders of magnitude increase in dark current upon neutron irradiation can be lowered substantially after processing them with a thermal annealing procedure, and single-photon detection are to some extent recovered at room temperature. Furthermore, we found no significant difference on neutron damaged behavior when SiPMs are irradiated at room temperature or in liquid nitrogen.

07 ISOTOPE AND RADIATION SOURCES↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗