Search NASA⌕ Search

SEARCH · Search NASA

Results for “Emission Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Positron emission reconstruction tomography for the assessment of regional myocardial metabolism by the administration of substrates labeled with cyclotron produced radionuclides

A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.

Ter-Pogossian, M. M.↗

Baroreflex regulation of blood pressure during dynamic exercise

From the work of Potts et al. Papelier et al. and Shi et al. it is readily apparent that the arterial (aortic and carotid) baroreflexes are reset to function at the prevailing ABP of exercise. The blood pressure of exercise is the result of the hemodynamic (cardiac output and TPR) responses, which appear to be regulated by two redundant neural control systems, "Central Command" and the "exercise pressor reflex". Central Command is a feed-forward neural control system that operates in parallel with the neural regulation of the locomotor system and appears to establish the hemodynamic response to exercise. Within the central nervous system it appears that the HLR may be the operational site for Central Command. Specific neural sites within the HLR have been demonstrated in animals to be active during exercise. With the advent of positron emission tomography (PET) and single-photon emission computed tomography (SPECT), the anatomical areas of the human brain related to Central Command are being mapped. It also appears that the Nucleus Tractus Solitarius and the ventrolateral medulla may serve as an integrating site as they receive neural information from the working muscles via the group III/IV muscle afferents as well as from higher brain centers. This anatomical site within the CNS is now the focus of many investigations in which arterial baroreflex function, Central Command and the "exercise pressor reflex" appear to demonstrate inhibitory or facilitatory interaction. The concept of whether Central Command is the prime mover in the resetting of the arterial baroreceptors to function at the exercising ABP or whether the resetting is an integration of the "exercise pressor reflex" information with that of Central Command is now under intense investigation. However, it would be justified to conclude, from the data of Bevegard and Shepherd, Dicarlo and Bishop, Potts et al., and Papelier et al. that the act of exercise results in the resetting of the arterial baroreflex. In addition, if, as we have proposed, the cardiopulmonary baroreceptors primarily monitors and reflexly regulates cardiac filling volume, it would seem from the data of Mack et al. and Potts et al. that the cardiopulmonary baroreceptor is also reset at the beginning of exercise. Therefore, investigations of the neural mechanisms of regulation involving Central Command and cardiopulmonary afferents, similar to those being undertaken for the arterial baroreflex, need to be established.

NASA Discipline Cardiopulmonary↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Plasma GFAP for populational enrichment of clinical trials in preclinical Alzheimer's disease

Abstract INTRODUCTION Cognitively unimpaired (CU) amyloid beta (Aβ)+ individuals with elevated plasma glial fibrillary acidic protein (GFAP) have an increased risk of Alzheimer's disease (AD)‐related progression. We tested the utility of plasma GFAP for population enrichment CU populations in clinical trials. METHODS We estimated longitudinal progression, effect size, and costs of hypothetical clinical trials designed to test an estimated 25% drug effect on reducing tau positron emission tomography (PET) accumulation in the medial temporal lobe (MTL) and temporal neocortical region (NEO‐T). RESULTS CU GFAP+/Aβ+ individuals present an increased annual rate of change and effect size in tau PET MTL and tau PET NEO‐T compared to the other groups. An enrichment strategy selecting CU GFAP+/Aβ+ individuals would require a smaller sample size (≈ 57% reduction) and fewer Aβ PET scans (≈ 74% reduction) than trials enriched with Aβ PET alone, reducing total clinical trial costs by up to 64%. DISCUSSION Our results suggest that clinical trials focusing on preclinical AD recruiting Aβ+ individuals with elevated GFAP levels would improve cost effectiveness. Highlights Cognitively unimpaired (CU) glial fibrillary acidic protein (GFAP)+/amyloid beta (Aβ)+ shows increased changes in tau positron emission tomography (PET) . CU GFAP+/Aβ+ enriched clinical trials require a reduced sample size compared to Aβ+ only. CU GFAP+/Aβ+ enrichment reduces Aβ PET scans required and costs. CU GFAP+/Aβ+ enrichment allows the selection of individuals at early stages of the Alzheimer's disease continuum.

Neurosciences & Neurology↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct Observations of Solute Dispersion in Rocks With Distinct Degree of Sub‐Micron Porosity

Abstract The transport of chemical species in rocks is affected by their structural heterogeneity to yield a wide spectrum of local solute concentrations. To quantify such imperfect mixing, advanced methodologies are needed that augment the traditional breakthrough curve analysis by probing solute concentration within the fluids locally. Here, we demonstrate the application of asynchronous, multimodality imaging by X‐ray computed tomography (XCT) and positron emission tomography (PET) to the study of passive tracer experiments in laboratory rock cores. The four‐dimensional concentration maps measured by PET reveal specific signatures of the transport process, which we have quantified using fundamental measures of mixing and spreading. We observe that the extent of solute spreading correlate strongly with the strength of subcore‐scale porosity heterogeneity measured by XCT, while dilution is enhanced in rocks containing substantial sub‐micron porosity. We observe that the analysis of different metrics is necessary, as they can differ in their sensitivity to the strength and forms of heterogeneity. The multimodality imaging approach is uniquely suited to probe the fundamental difference between spreading and mixing in heterogeneous media. We propose that when multi‐dimensional data is available, mixing and spreading can be independently quantified using the same metric. We also demonstrate that one‐dimensional transport models have limited predictive ability toward the internal evolution of the solute concentration, when the model is solely calibrated against the effluent breakthrough curves. The data set generated in this study can be used to build realistic digital rock models and to benchmark transport simulations that account deterministically for rock property heterogeneity.

Kurotori, Takeshi [Department of Chemical Engineer↗

Electroencephalographic imaging of higher brain function

High temporal resolution is necessary to resolve the rapidly changing patterns of brain activity that underlie mental function. Electroencephalography (EEG) provides temporal resolution in the millisecond range. However, traditional EEG technology and practice provide insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. Recent advances help to overcome this problem by recording EEGs from more electrodes, by registering EEG data with anatomical images, and by correcting the distortion caused by volume conduction of EEG signals through the skull and scalp. In addition, statistical measurements of sub-second interdependences between EEG time-series recorded from different locations can help to generate hypotheses about the instantaneous functional networks that form between different cortical regions during perception, thought and action. Example applications are presented from studies of language, attention and working memory. Along with its unique ability to monitor brain function as people perform everyday activities in the real world, these advances make modern EEG an invaluable complement to other functional neuroimaging modalities.

Non-NASA Center↗

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Preferential Solute Transport in Low Permeability Zones During Spontaneous Imbibition in Heterogeneous Porous Media

Multiphase flows in porous media|and the associated solute transport processes|are controlled by a combination of gravity, capillary, and viscous forces. Geologic heterogeneity influences flow and transport processes, yet gaps exist in our understanding of how heterogeneity impacts capillary-driven transport, such as during spontaneous imbibition. Here we use positron emission tomography, combined with a newly developed method for conducting spontaneous imbibition experiments, to observe solute transport into low permeability regions during imbibition. Using an experimentally parameterized 2D numerical model, we demonstrate how capillary-driven ow near the imbibition front can carry solutes into low permeability regions. This process displaces solutes from high permeability zones while the cumulative amount of solute in low permeability zones increases- opposite of what is observed under fully saturated solute transport conditions. These results highlight the complex flow and solute transport behavior that arise during multiphase displacements in heterogeneous geologic porous media.

58 GEOSCIENCES↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗

Diagnostic imaging applications; Proceedings of the Meeting, Amsterdam, Netherlands, October 8, 9, 1984

It is more important than ever that engineers have an understanding of the future needs of clinical and research medicine, and that physicians know somthing about probable future developments in instrumentation capabilities. Only by maintaining such a dialog can the most effective application of technological advances to medicine be achieved. This workshop attempted to provide this kind of information transfer in the limited field of diagnostic imaging. Biomedical research at the Jet Propulsion Laboratory is discussed, taking into account imaging results from space exploration missions, as well as biomedical research tasks based in these technologies. Attention is also given to current and future indications for magnetic resonance in medicine, high speed quantitative digital microscopy, computer processing of radiographic images, computed tomography and its modern applications, position emission tomography, and developments related to medical ultrasound.

Beckenbach, E. S.↗

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

Poisson-response Tensor-on-Tensor Regression and Applications

We introduce Poisson-response tensor-on-tensor regression (PToTR), a novel regression framework designed to handle tensor responses composed element-wise of random Poisson-distributed counts. Tensors, or multi-dimensional arrays, composed of counts are common data in fields such as inter national relations, social networks, epidemiology, and medical imaging, where events occur across multiple dimensions like time, location, and dyads. PToTR accommodates such tensor responses alongside tensor covariates, providing a versatile tool for multi dimensional data analysis. We propose algorithms for maximum likelihood estimation under a canonical polyadic (CP) structure on the regression coefficient tensor that satisfy the positivity of Poisson parameters and then provide an initial theoretical error analysis for PToTR estimators. We also demonstrate the utility of PToTR through three concrete applications: longitudinal data analysis of the Integrated Crisis Early Warning System database, positron emission tomography (PET) image reconstruction, and change-point detection of communication patterns in longitudinal dyadic data. These applications highlight the versatility of PToTR in addressing complex, structured count data across various domains.

97 MATHEMATICS AND COMPUTING↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

[ 89 Zr]Zr-DFO-TOC: a novel radiopharmaceutical for PET imaging of somatostatin receptor positive neuroendocrine tumors

Neuroendocrine tumors (NETs) are clinically diverse types of tumors that can arise anywhere in the body. Previous studies have shown that somatostatin receptors (SSTRs) are overexpressed on NET cell membranes relative to healthy tissue, allowing for tumor targeting through radiolabeled somatostatin analogs (SSAs). This work aims to develop a novel 89 Zr-labeled tracer incorporating the SSA, octreotide (TOC), for positron emission tomography (PET) imaging of SSTR + NETs and predictive dosimetry calculations, leveraging the excellent nuclear (t ½ = 3.27 days, β+ = 22.3%, β + avg = 395.5 keV) and chemical characteristics (+ 4 oxidation state, preferential coordination number of 7/8, favorable aqueous chemistry) of 89 Zr. In combination with 89 Zr, the known radiochemistry with the chelator deferoxamine (DFO) gives reason to believe that this radiopharmaceutical incorporating an octreotide conjugate will be successful in studying the suitability of detecting SSTR + NETs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinct effects of beta-amyloid and tau on cortical thickness in cognitively healthy older adults

Published reports of associations between β-amyloid (Aβ) and cortical integrity conflict. Tau biomarkers may help elucidate the complex relationship between pathology and neurodegeneration in aging. We measured cortical thickness using magnetic resonance imaging, Aβ using Pittsburgh compound B positron emission tomography (PiB-PET), and tau using flortaucipir (FTP)-PET in 125 cognitively normal older adults. We examined relationships among PET measures, cortical thickness, and cognition. Cortical thickness was reduced in PiB+/FTP+ participants compared to the PiB+/FTP– and PiB–/FTP– groups. Continuous PiB associations with cortical thickness were weak but positive in FTP– participants and negative in FTP+. FTP strongly negatively predicted thickness regardless of PiB status. FTP was associated with memory and cortical thickness, and mediated the association of PiB with memory. Past findings linking Aβ and cortical thickness are likely weak due to opposing effects of Aβ on cortical thickness relative to tau burden. Tau, in contrast to Aβ, is strongly related to cortical thickness and memory.

60 APPLIED LIFE SCIENCES↗