Search NASA⌕ Search

SEARCH · Search NASA

Results for “Emissions Minimization Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techno-economic assessment of emissions mitigation technologies for post-combustion CO2 capture using AMP/PZ

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for meeting environmental permitting regulations and ensuring public acceptance. Experimental test campaigns at the CO₂ capture pilot plant in Niederaussem using CESAR1 demonstrated that integrating available emission abatement technologies can significantly reduce the concentration of amines and degradation products in CO₂-depleted flue gas to below the detection limit of an infrared spectrometer. The study confirmed that proprietary dry bed technology (OEASE Aerozone™) or a second water wash can lower AMP and PZ emissions to below 1 mg/Nm³. However, to achieve very low NH₃ emissions below 2 mg/Nm³, an acid or other chemically active wash downstream of the water wash is required. A configuration with a dry bed or a double water wash results in a carbon capture cost (CCC) of 44 €/tCO₂, and a CO₂ avoided cost (CAC) of 86 €/tCO₂. A configuration with an acid wash increases the CCC to 47 €/tCO₂ and the CAC to 90 €/tCO₂ due to the amine losses in the acid waste and its treatment.

CO2 capture↗

Direct Air Capture and Utilization System (DACUS): FEED Study of CarbonCapture Inc. DAC and CarbonCure Utilization Technologies Using United States Steel’s Gary Works Plant Waste Heat

The effects of climate change are drastically perceived through the alarming rates of severe events such as flooding, hurricanes, wildfires, global temperature rise, sea-level rise, and ocean acidification etc., which has prompted the nations across the globe to control & reduce greenhouse gas (GHG) emissions, by massive adoption of electric vehicles, switching to renewal energy sources and promoting sustainable green products. However, recent climate studies have shown that such efforts will not be enough to keep the global temperature rising under 1.5° Celsius by the year 2050, which lead to the development of multiple Direct Air Capture (DAC) technologies. A DAC system extracts CO2 directly from the atmosphere, which is either stored underground for long term or utilized in other processes. The DACUS proposed at U.S. Steel Corporation’s Gary Works Plant in Gary, Indiana, will include an innovative DAC technology from CarbonCapture Inc. (CCI), which will be collocated and powered by waste heat from the steel plant to capture CO2 from ambient air, and CarbonCure CO2 utilization technology- which is a commercial technology that is already installed and in use by early adopters in more than 150 concrete mixing plants across North America and Asia. The University of Illinois at Urbana Champaign spearheaded this Front-End Engineering Design (FEED) study project, which was funded by US Department of Energy (DOE), aimed at designing a state-of-the art DACU system that can remove minimum of 5,000 tonne/year net CO2 from air (based on cradle-to-gate LCA) and converting the captured CO2 into low carbon intensity products. The off takers of the low Carbon product produced by the DACUS have also been identified near the steel plant in the Indiana, Illinois & Wisconsin Region. This creates a full CO2 value chain and provides a means to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice. DACUS is a promising new technology for reducing greenhouse gas in the atmosphere. Operation costs are minimized by locating CCI’s innovative DAC collector at United States Steel's Gary Works site where waste heat is utilized. Carbon emissions are minimized in CO2 transportation. The captured CO2 will be permanently sequestered in concrete used as construction material. This DOE funded FEED study demonstrates a full CO2 value chain for a DACU system, supported by an industrial facility. If this project were constructed, it would have a very positive and lasting impact on both the environment and the community.

42 ENGINEERING↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Bioblendstocks to Optimize Mixing Controlled Compression Ignition (MCCI) Engines

In this project, a team of researchers from the University of Massachusetts Lowell, the University of Maine, and Mainstream Engineering developed an integrated process for the product of bioblendstocks to optimize mixing controlled compression ignition (MCCI) engines. The objective was to improve the energy density, sooting propensity, and cetane number of base diesel fuel while maintaining cold weather behavior. The process converts woody biomass (e.g. sawmill residues) into bio-oil through selective fast pyrolysis; the bio-oil is then selectively upgraded to form selectively oxygenated, minimally-branched hydrocarbons using non-noble metal catalysts in combination with metal-catalyzed hydrogenation. Advanced predictive models, in conjunction with existing property databases, and experimental testing are used to evaluate overall bioblendstock properties and their impact on base diesel fuel. An iterative, targeted upgrading approach was implemented to optimize the proposed bioblendstock’s properties. Assessment methodologies included techno-economic analysis, life-cycle assessment, property testing, and engine testing. Ultimately, the project team successfully produced a viable bioblendstock while identifying critical process points related to scale-up efforts. It was found that producing pyrolysis oils at 500 degrees C and with pine particle sizes of 1-2 mm led to bio-oil with a higher yield (of approximately 45 wt%) and rich amounts of aromatic alcohols. The resultant pyrolysis oil was then upgraded using a sequence of mild hydrotreating, followed by catalytic etherification and esterification, followed by another final mild hydrotreating to produce a blendstock containing saturated species with a limited, but non-zero, amount of oxygen. The aromatic alcohols produced by pyrolysis were especially helpful in this regard, as the resulting bicycloethers and derivatives exhibited high cetane numbers. While most bulk properties of the bioblendstock met or exceeded targeted thresholds, viscosity and cloud point notably fell outside the expected range; this could be addressed by blending limits and/or through the use of additives that are commonplace in current refinding practices. Identification of a bioblendstock that can be produced economically at scale while improving the performance and emissions characteristics of internal combustion engines positively affects the economy by boosting domestic fuel production and the environment by decreasing harmful emissions and increasing efficiency.

09 BIOMASS FUELS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗