At least 55 records · Page 3

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

BuildingsBench: A Benchmark for Universal Building Load Forecasting [SWR-23-51]

The residential and commercial building stock in the United States is responsible for a significant percentage of energy consumption and greenhouse gas emissions. Electrification of end-uses, as well as decarbonizing the electrical grid through renewable energy sources such as solar and wind, constitutes the pathway to zero-emission buildings. Forecasting day-ahead building energy consumption is an integral part of this solution. Currently, specialized forecasting models are hand-made for each individual building, which is time-consuming, expensive, and leads to duplicated efforts. BuildingsBench is a Python software framework for training and comparing generalized machine learning models for universal building load forecasting. This challenge tasks a single foundational model to generalize its forecasts for a wide variety of buildings, across geographic regions, building types, weather patterns, and more. This software provide code for pre-training such models and subsequently evaluating their performance on a suite of hundreds of diverse real and synthetic buildings. BuildingsBench is a platform for: - Large-scale pretraining with the synthetic Buildings-900K dataset for short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock and is extracted from the NREL End-Use Load Profiles database. - Benchmarking on two tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. We provide an index-based PyTorch Dataset for large-scale pretraining, easy data loading for multiple real building energy consumption datasets as PyTorch Tensors or Pandas DataFrames, simple (persistence) to advanced (transformer) baselines, metrics management, and more.

Emami, Patrick↗

ComStock™ 2024 Release 1 [SWR-19-33 and SWR-20-32]

ComStock™ is an NREL model of the U.S. commercial building stock. The model takes some building characteristics from the U.S. Department of Energy's (DOE's) Commercial Prototype Building Models and Commercial Reference Building. However, unlike many other building stock models, ComStock also combines these with a variety of additional public- and private-sector data sets. Collectively, this information provides high-fidelity building stock representation with a realistic diversity of building characteristics. This repository contains the source code used to build and execute ComStock models, including upgrade scenarios. In addition, the sampling of buildings characteristics used for the initial ComStock (V1.0) release is provided. The ComStock model is under active calibration and development, which is publicly visible on this repository. Execution of the ComStock workflow is managed through the buildstockbatch repository, a shared asset of ResStock™ and ComStock™ , specifically developed to scale to execution of tens of millions of simulations through multiple infrastructure providers. The dataset output from the initial ComStock (V1.0) release can be found at the accompanying ComStock data viewer website and additional information about ComStock found on the NREL Buildings Website. For more details about ongoing model development please consult the End Use Load Profiles website. ComStock is a direct result of the NREL residential stock modeling tool ResStock™ (recipient of a R&D100 award) and was inspired by the high-fidelity solar & storage adoption model dGen™. Additionally, this tool would not be possible without the decades of work undertaken by the OpenStudio® and EnergyPlus® visionaries and contributors, significant funding, feedback and support from the Los Angeles Department of Water and Power, and the Department of Energy's Building Technology Office ongoing support of and investment in building energy modeling software. is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

ComStock Measure Documentation: Interior Lighting Controls

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of fuel cell on-site, integrated energy systems in residential/commercial applications

Three building applications were selected for a detailed study: a low rise apartment building; a retail store, and a hospital. Building design data were then specified for each application, based on the design and construction of typical, actual buildings. Finally, a computerized building loads analysis program was used to estimate hourly end use load profiles for each building. Conventional and fuel cell based energy systems were designed and simulated for each building in each location. Based on the results of a computer simulation of each energy system, levelized annual costs and annual energy consumptions were calculated for all systems.

Wakefield, R. A.↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Introduction to ComStock

This presentation is an introduction to ComStock and the datasets it produces. The goal of this work is to help cities, states, utilities, and other stakeholders have information and resources needed to make informed decisions about their building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification Futures Study Flexible Load Profiles

This data set includes hourly profiles for flexible load developed for the Electrification Futures Study (EFS). The load profiles represent projected end-use electricity demand that is assumed to be flexible (i.e., can be shifted throughout a day) for various scenarios of flexibility (Base, Enhanced), electrification (Reference, Medium, High), and technology advancement (Slow, Moderate, Rapid), and were developed as inputs into the ReEDS model. The quantity of flexible load is estimated using assumptions on the level of flexibility and customer participation within each subsector modeled in the EFS. Detailed assumptions and modeling implementation will be documented in ongoing EFS analyses. Flexible load profiles are provided for a subset of years (2018, 2020, 2024, 2030, 2040, 2050) and are aggregated to the state and sector level. Total electricity load profiles can be found in a related EFS data set (https://dx.doi.org/10.7799/1593122). NOTE: Due to the file size, Mac users may experience issues decompressing the zip files using the Mac Archive Utility. In those cases, decompressing using the command line is recommended. - Mai, Trieu, Paige Jadun, Jeffrey Logan, Colin McMillan, Matteo Muratori, Daniel Steinberg, Laura Vimmerstedt, Ryan Jones, Benjamin Haley, and Brent Nelson. 2018. Electrification Futures Study: Scenarios of Electric Technology Adoption and Power Consumption for the United States. National Renewable Energy Laboratory. NREL/TP-6A20-71500. https://doi.org/10.2172/1459351. - Murphy, Caitlin, Trieu Mai, Yinong Sun, Paige Jadun, Matteo Muratori, Brent Nelson, Ryan Jones. Forthcoming. Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States. National Renewable Energy Laboratory. - Sun, Yinong, Paige Jadun, Brent Nelson, Matteo Muratori, Caitlin Murphy, Jeffrey Logan, and Trieu Mai. Forthcoming. Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification. National Renewable Energy Laboratory.

buildings↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.