Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

ComStock™ [SWR-19-33 and SWR-20-32]

ComStock™ is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

ComStock™ 2024 Release 1 [SWR-19-33 and SWR-20-32]

ComStock™ is an NREL model of the U.S. commercial building stock. The model takes some building characteristics from the U.S. Department of Energy's (DOE's) Commercial Prototype Building Models and Commercial Reference Building. However, unlike many other building stock models, ComStock also combines these with a variety of additional public- and private-sector data sets. Collectively, this information provides high-fidelity building stock representation with a realistic diversity of building characteristics. This repository contains the source code used to build and execute ComStock models, including upgrade scenarios. In addition, the sampling of buildings characteristics used for the initial ComStock (V1.0) release is provided. The ComStock model is under active calibration and development, which is publicly visible on this repository. Execution of the ComStock workflow is managed through the buildstockbatch repository, a shared asset of ResStock™ and ComStock™ , specifically developed to scale to execution of tens of millions of simulations through multiple infrastructure providers. The dataset output from the initial ComStock (V1.0) release can be found at the accompanying ComStock data viewer website and additional information about ComStock found on the NREL Buildings Website. For more details about ongoing model development please consult the End Use Load Profiles website. ComStock is a direct result of the NREL residential stock modeling tool ResStock™ (recipient of a R&D100 award) and was inspired by the high-fidelity solar & storage adoption model dGen™. Additionally, this tool would not be possible without the decades of work undertaken by the OpenStudio® and EnergyPlus® visionaries and contributors, significant funding, feedback and support from the Los Angeles Department of Water and Power, and the Department of Energy's Building Technology Office ongoing support of and investment in building energy modeling software. is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

IS BLOCKCHAIN A SUITABLE TECHNOLOGY FOR ENSURING THE INTEGRITY OF DATA SHARED BY LIGHTING AND OTHER BUILDING SYSTEMS?

Increasing amounts of data are available from lighting and other building systems. In commercial buildings, these data can be used to improve system and energy performance, detect and diagnose faults, and facilitate maintenance. Building data are not only of interest to owners and operators of the building systems, however. Owners and operators of similar buildings, manufacturers of building systems, utilities, and city agencies also have interesting use cases. Energy data can, for example, be used to verify the performance of energy-conservation measures, issue renewableenergy certificates, and financially settle grid services. Increased data sharing, however, significantly expands the cyber-attack surface, creating new challenges. In this work, blockchain is explored as an option for ensuring the integrity of data that are shared by lighting and other building systems. Blockchain fundamentals and variants are briefly reviewed, and value propositions relevant to building systems are discussed. A recently developed blockchain applicability framework (BAF) that builds upon and addresses the limitations of previous applicability models is also briefly reviewed. The BAF is used to assess the suitability of blockchain over other technologies or approaches for building-data applications, using emerging connected lighting systems as an example use case.

blockchain, connected lighting system, data integr↗

GSA Oklahoma City Federal Building: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the project roles, processes, costs, and benefits. The findings from this successful GEB project can be used to help pave the way for additional GEB-ready retrofits in the future. The General Services Administration’s (GSA’s) Oklahoma City (OKC) Federal Building, located in downtown Oklahoma City, Oklahoma, demonstrates that GEB-ready strategies and technologies can be realistically deployed today across buildings with minimal investment. The project team implemented nine energy conservation measures (ECMs) and/or smart building technologies, making it a leading example of a smart, sustainable, and efficient commercial building. The case study highlights the challenges and the lessons learned throughout the project design and execution in addition to some of the best practices and considerations when implementing GEB technologies.

Butrico, Mark↗

Commissioning Guidance for Energy Savings Performance Contracts (ESPCs)

This Commissioning Guidance for Energy Savings Performance Contracts (ESPCs) is DOE’s official guidance for ordering agencies under the current DOE ESPC IDIQ contract. This guidance document explains how commissioning of energy conservation measures (ECMs) and water conservation measures (WCMs) is incorporated into the ESPC process, roles and responsibilities in project commissioning, and key elements of commissioning. This document updates the previous version, released in 2015. This guidance can also be used as applicable in the development of ESPC ENABLE and UESC performance assurance plans.

Walker, Christine↗

Two (or more) for one: Identifying classes of household energy- and water-saving measures to understand the potential for positive spillover

A key component of behavior-based energy conservation programs is the identification of target behaviors. A common approach is to target behaviors with the greatest energy-saving potential. The concept of behavioral spillover introduces further considerations, namely that adoption of one energy-saving behavior may increase (or decrease) the likelihood of other energy-saving behaviors. This research aimed to identify and describe household energy- and water-saving measure classes within which positive spillover is likely to occur (e.g., adoption of energy-efficient appliances may correlate with adoption of water-efficient appliances), and explore demographic and psychographic predictors of each. Nearly 1,000 households in a California city were surveyed and asked to report whether they had adopted 75 different energy- and/or water-saving measures. Principal Component Analysis and Network Analysis based on correlations between adoption of these diverse measures revealed and characterized eight water-energy-saving measure classes: Water Conservation, Energy Conservation, Maintenance and Management, Efficient Appliance, Advanced Efficiency, Efficient Irrigation, Green Gardening, and Green Landscaping. Understanding these measure classes can help guide behavior-based energy program developers in selecting target behaviors and designing interventions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Assurance Planning Guide for Utility Energy Service Contracts: 2025 Edition

Administered by the U.S. Department of Energy's (DOE) Federal Energy Management Program (FEMP), the Utility Program has fostered collaboration among federal agencies and their serving utilities for more than 25 years. The Utility Program supports agencies using Utility Energy Service Contracts (UESCs), a well-developed, effective contracting vehicle that enable the latest approaches to cost-effective energy management at federal sites. Federal agencies have successfully used UESCs to award over 2,000 energy and water efficiency and renewable energy projects, investing approximately $\$$2.8 billion in furthering the Federal Government's efforts to reduce energy intensity. Authorized by 42 U.S. Code section 8256 (10 U.S. Code section 2913 for the Department of Defense), a UESC is a limited-source acquisition between a federal agency and an eligible serving utility for energy management services that generate savings from the implementation of energy- and water -conservation measures (collectively referred to as ECMs), with 42 U.S. Code section 8287 (Defense Federal Acquisition Regulation Supplement, Part 241), providing the term of a UESC, which may extend up to 25 years. Through a UESC, the utility partner assesses designs, and implements the desired ECMs - which can range from lighting retrofits and renewable energy systems, to combined heat and power plants or other technologies and strategies, and may provide financing for the project. The agency may use any combination of appropriations and third-party financing to pay for the project, providing useful flexibility. There is no limit to the project size, big or small, that can be implemented using a UESC. To assist agencies implementing a UESC, FEMP has developed a Utility Energy Service Contract Guide and this companion guidance document to help agencies and their utility partners better understand the best practices for to ensure UESCs continue to perform and generate savings throughout their performance period. These best practices utilize a combination of effective project management, communication, documentation, and a detailed Performance Assurance Plan. This plan is a project specific set of actionable protocols that define important tasks and responsibilities throughout the contract term and reflects the site conditions, complexities, agency capabilities, and operating and maintaining planned ECMs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗

Evaluating cross-sectoral impacts of climate change and adaptations on the energy-water nexus: a framework and California case study

Abstract Electricity and water systems are inextricably linked through water demands for energy generation, and through energy demands for using, moving, and treating water and wastewater. Climate change may stress these interdependencies, together referred to as the energy-water nexus, by reducing water availability for hydropower generation and by increasing irrigation and electricity demand for groundwater pumping, among other feedbacks. Further, many climate adaptation measures to augment water supplies—such as water recycling and desalination—are energy-intensive. However, water and electricity system climate vulnerabilities and adaptations are often studied in isolation, without considering how multiple interactive risks may compound. This paper reviews the fragmented literature and develops a generalized framework for understanding these implications of climate change on the energy-water nexus. We apply this framework in a case study to quantify end-century direct climate impacts on California’s water and electricity resources and estimate the magnitude of the indirect cross-sectoral feedback of electricity demand from various water adaptation strategies. Our results show that increased space cooling demand and decreased hydropower generation are the most significant direct climate change impacts on California’s electricity sector by end-century. In California’s water sector, climate change impacts directly on surface water availability exceed demand changes, but have considerable uncertainty, both in direction and magnitude. Additionally, we find that the energy demands of water sector climate adaptations could significantly affect California’s future electricity system needs. If the worst-case water shortage occurs under climate change, water-conserving adaptation measures can provide large energy savings co-benefits, but other energy-intensive water adaptations may double the direct impacts of climate change on the state’s electricity resource requirement. These results highlight the value of coordinated adaptation planning between the energy and water sectors to achieve mutually beneficial solutions for climate resilience.

54 ENVIRONMENTAL SCIENCES↗

A Fundamentally New Coupled Approach to Contact Mechanics via the Dirichlet‐Neumann Schwarz Alternating Method

Contact phenomena are crucial for understanding the behavior of mechanical systems. However, existing computational approaches for simulating mechanical contact often face numerical challenges, such as inaccurate physical predictions, energy conservation errors, and unwanted oscillations. Here, we introduce an alternative technique for simulating dynamic contact based on the non‐overlapping Schwarz alternating method, originally developed for domain decomposition. In multibody contact scenarios, this method treats each body as a separate, non‐overlapping domain and prevents interpenetration using an alternating Dirichlet–Neumann iterative process. This approach has a strong theoretical foundation, eliminates the need for contact constraints, and offers flexibility, making it ideal for multiscale and multiphysics applications. We conducted a numerical comparison between the Schwarz method and traditional methods, such as the Lagrange multiplier and penalty methods, focusing on a benchmark impact problem. Our results indicate that the Schwarz alternating method outperforms traditional methods in several key areas: it provides more accurate predictions for various measurable quantities and demonstrates exceptional energy conservation capabilities. To address unwanted oscillations in contact velocities and forces, we explored various algorithms and stabilization techniques, ultimately opting for the naïve‐stabilized Newmark scheme for its simplicity and effectiveness. Additionally, we validated the efficiency of the Schwarz method in a three‐dimensional impact problem, highlighting its inherent capacity to accommodate different mesh topologies, time‐integration schemes, and time steps for each interacting body.

Schwarz alternating method↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

Evaluating How Climate Adaptation Measures Affect the Interconnected Water‐Energy Resource Systems of the Western United States

Abstract The Western US faces increasing water stress from the impacts of climate change, making it difficult to meet water demands for the region's cities, agriculture, and hydropower generators. Existing literature suggests that climate adaptation measures such as water conservation, cropland retirement, wastewater recycling, and managed aquifer recharge can alleviate some of these challenges. Few analyses, however, compare the relative efficacy and system‐wide effects of these adaptations under different climate projections across the entire Western United States. Here we use a Western US‐wide water systems model to evaluate, by sector and sub‐region, how the widespread implementation of these adaptive measures impacts water demands, water deliveries, and electricity use related to the water system for three different climate projections. We find that wastewater recycling has greater potential to lower unmet indoor water demands than urban indoor water conservation measures. However, when implemented at scale, indoor water conservation reduces electricity use by an average of 683 Terawatt hours while wastewater recycling increases energy use by an average of 721 Terawatt hours, cumulatively from 2020 to 2070. Cropland retirement and aquifer recharge adaptations increase the ability to meet agricultural water demand, increase groundwater storage, and reduce summertime electricity use. While most of these findings are consistent across different climate projections, the benefits of aquifer recharge are sensitive to spatial variation of precipitation. Given the limitations and tradeoffs of each individually, the results suggest that a portfolio of adaptation measures will be needed for a climate‐resilient water and energy future in the Western US. Plain Language Summary The Western US faces increased water stress from the impacts of climate change, making it difficult to meet demands for cities, agriculture, and hydropower facilities. Adaptation measures like water conservation, retiring agricultural lands, recycling wastewater, and storing water underground can address these challenges. However, there is little modeling to understand the impact of these adaptations if they were implemented across the entire Western US while also considering climate change. We use a Western US‐wide water systems model to evaluate how implementing adaptation measures impacts groundwater levels, the ability to meet water demands, and electricity use related to water in three different possible climate futures. We find that recycling wastewater to drinking water standards does a better job of meeting urban water demands than water conservation measures. However, indoor water conservation reduces energy use for water while recycling wastewater increases energy use for water. Retiring agricultural lands and storing water underground both increase the ability to meet agricultural water demands, increase underground water storage, and reduce summertime energy use. No adaptation measures provides benefits across every metric we track. Therefore, multiple adaptation measures will likely be needed to achieve a climate‐resilient future for energy and water in the Western US. Key Points Water‐related climate change adaptations have different benefits and tradeoffs for interconnected water‐energy systems in the Western U.S. Wastewater recycling most increases urban water coverage, but has a significant tradeoff in the form of greater electricity use Cropland retirement and aquifer recharge benefit water and electricity systems most in the summer when those systems are most stressed

Singhal, A↗