At least 55 records · Page 3

Fast Learning for Immersive Engagement in Energy Simulations

The fast computation which is critical for immersive engagement with and learning from energy simulations would be furthered by developing a general method for creating rapidly computed simplified versions of NREL's computation-intensive energy simulations. Created using machine learning techniques, these 'reduced form' simulations can provide statistically sound estimates of the results of the full simulations at a fraction of the computational cost with response times - typically less than one minute of wall-clock time - suitable for real-time human-in-the-loop design and analysis. Additionally, uncertainty quantification techniques can document the accuracy of the approximate models and their domain of validity. Approximation methods are applicable to a wide range of computational models, including supply-chain models, electric power grid simulations, and building models. These reduced-form representations cannot replace or re-implement existing simulations, but instead supplement them by enabling rapid scenario design and quality assurance for large sets of simulations. We present an overview of the framework and methods we have implemented for developing these reduced-form representations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Model to Simulate Energy Performance of VRF Systems

This paper presents a new model to simulate energy performance of variable refrigerant flow (VRF) systems in heat pump operation mode (either cooling or heating is provided but not simultaneously). The main improvement of the new model is the introduction of the evaporating and condensing temperature in the indoor and outdoor unit capacity modifier functions. The independent variables in the capacity modifier functions of the existing VRF model in EnergyPlus are mainly room wet-bulb temperature and outdoor dry-bulb temperature in cooling mode and room dry-bulb temperature and outdoor wet-bulb temperature in heating mode. The new approach allows compliance with different specifications of each indoor unit so that the modeling accuracy is improved. The new VRF model was implemented in a custom version of EnergyPlus 7.2. This paper first describes the algorithm for the new VRF model, which is then used to simulate the energy performance of a VRF system in a Prototype House in California that complies with the requirements of Title 24 ? the California Building Energy Efficiency Standards. The VRF system performance is then compared with three other types of HVAC systems: the Title 24-2005 Baseline system, the traditional High Efficiency system, and the EnergyStar Heat Pump system in three typical California climates: Sunnyvale, Pasadena and Fresno. Calculated energy savings from the VRF systems are significant. The HVAC site energy savings range from 51 to 85percent, while the TDV (Time Dependent Valuation) energy savings range from 31 to 66percent compared to the Title 24 Baseline Systems across the three climates. The largest energy savings are in Fresno climate followed by Sunnyvale and Pasadena. The paper discusses various characteristics of the VRF systems contributing to the energy savings. It should be noted that these savings are calculated using the Title 24 prototype House D under standard operating conditions. Actual performance of the VRF systems for real houses under real operating conditions will vary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying the Collective Functional Response of a Receptor in Alchemical Ligand Binding Free Energy Simulations with Accelerated Solvation Layer Dynamics

Ligand binding free energy simulations (LB-FES) that involve sampling of protein functional conformations have been longstanding challenges in research on molecular recognition. Particularly, modeling of the conformational transition pathway and design of the heuristic biasing mechanism are severe bottlenecks for the existing enhanced configurational sampling (ECS) methods. Inspired by the key role of hydration in regulating conformational dynamics of macromolecules, this report proposes a novel ECS approach that facilitates binding-associated structural dynamics by accelerated hydration transitions in combination with the lambda-exchange of free energy perturbation (FEP). Further, two challenging protein-ligand binding processes involving large configurational transitions of the receptor are studied, with hydration transitions at binding sites accelerated by Hamiltonian-simulated annealing of the hydration layer. Without the need for pathway analysis or ad hoc barrier flattening potential, LB-FES were performed with FEP/lambda-exchange molecular dynamics simulation at a minor overhead for annealing of the hydration layer. The LB-FES studies showed that the accelerated rehydration significantly enhances the collective conformational transitions of the receptor, and convergence of binding affinity calculations is obtained at a sweet-spot simulation time scale. Alchemical LB-FES with the proposed ECS strategy is free from the effort of trial and error for the setup and realizes efficient on-the-fly sampling for the collective functional response of the receptor and bound water and therefore presents a practical approach to high-throughput screening in drug discovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗

Offshore Wind ENergy Simulation Toolkit (OWENS)

SAND2021-2751 O The Offshore Wind ENergy Simulation Toolkit (OWENS) is a collection of aerodynamic, structural, hydrodynamic, drivetrain, controls, composite structure and mesh preprocessing, and data postprocessing. OWENS is primarily an ontology, or glue code, pulling together many open-source and Sandia-developed libraries to model the aero-servo-hydro-elastic physics of wind and marine energy turbines. The toolkit’s intended use is for arbitrary aeroelastic rotor configurations analysis including vertical-axis wind turbines, horizontal-axis wind turbines, and analogous marine energy applications for fixed-bottom and floating configurations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525

Owens, Brian↗

An Enhanced Vertical Ground Heat Exchanger Model for Whole-Building Energy Simulation

This paper presents an enhanced vertical ground heat exchanger (GHE) model for whole-building energy simulation (WBES). WBES programs generally have computational constraints that affect the development and implementation of component simulation sub-models. WBES programs require models that execute quickly and efficiently due to how the programs are utilized by design engineers. WBES programs also require models to be formulated so their performance can be determined from boundary conditions set by upstream components and environmental conditions. The GHE model developed during this work utilizes an existing response factor model and extends its capabilities to accurately and robustly simulate at timesteps that are shorter than the GHE transit time. This was accomplished by developing a simplified dynamic borehole model and then exercising that model to generate exiting fluid temperature response factors. This approach blends numerical and analytical modeling methods. The existing response factor models are then extended to incorporate the exiting fluid temperature response factor to provide a better estimate of the GHE exiting fluid temperature at short simulation timesteps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Design and Laboratory Characterization of a Medium- and High-Efficiency Rooftop Unit for use in Building Energy Simulations

Commercial rooftop units that incorporate variable speed components are quickly entering into the market place; however, the design and modeling tools that calculate the energy benefits of these units cannot properly estimate performance. This is due to two factors: 1) There are insufficient measured performance data of real systems that can be entered into these simulations, and 2) building energy simulators are unable to properly interpret performance data. Therefore, publicly available datasets designed to encompass the entire performance map coupled with control sequence information are needed as inputs for these modelling programs to accurately estimate energy savings and promote variable speed RTUs. As part of the Verification and Uncertainty Characterization for Energy Simulation milestone funded by the Department of Energy, the National Renewable Energy Laboratory recorded and published data across the entire performance range for two commercially available RTUs; one with a two-stage compressor and variable speed supply fan, and another with a fully variable speed compressor, supply fan and condenser fan. This paper details 1) how the design of experiments was created as well as how the units were controlled, and 2) the operational limitations of the two units. The paper will also discuss methods for building energy simulation programs to properly interpret these data sets and integrate them into building energy simulation models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Simulation Test for Existing Homes (BESTEST-EX) Methodology: Preprint

The test suite represents a set of cases applying the new Building Energy Simulation Test for Existing Homes (BESTEST-EX) Methodology developed by NREL. (Judkoff et al. 2010a). The NREL team developed the test cases in consultation with the home retrofit industry (BESTEST-EX Working Group 2009), and adjusted the test specifications in accordance with information supplied by a participant withaccess to large utility bill datasets (Blasnik 2009).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Configurational Sampling Approaches to Alchemical Ligand Binding Free Energy Simulations: Current Status and Challenges

In this study, ligand binding free energy simulations (LB-FES) have been routine tasks in modern drug discovery campaign. A long-standing challenge for LB-FES is the difficulty in adequately sampling nontrivial environmental reorganizations in response to ligand binding. Therefore, various enhanced configurational sampling (ECS) approaches were devised to speed up fluctuations of relevant slow degrees of freedom (SDOF) and ensure simulation convergence. However, in contrast to the achievements in parametrization, software performance, and workflow automation, efficient ECS methodology suitable for high throughput screening remains in an early stage of development. Here, a review of ECS developments with LB-FES is presented, revisiting current approaches and underlining the major technical pitfalls and challenges. This Perspective focuses on alchemical LB-FES on account of their predominant role in high throughput drug screening as well as the established partnership with ECS. The critical aspects of designing ECS approaches, from both theoretical and applied perspectives, are described. This work is intended to provide a contemporary review of the scientific, technical, and practical issues associated with the accelerating convergence of alchemical LBFES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A rigorous physics-based enhanced parameter estimation (EPE) methodology for calibration of building energy simulations

Buildings rarely perform as designed/simulated and there are numerous tangible benefits if this gap is reconciled. A new scientifically rigorous yet pragmatic methodology for calibrating building energy simulations - called Enhanced Parameter Estimation (EPE) - is proposed that allows physically relevant parameter estimation rather than a blind force-fit to energy use data. Starting with a rapidly created simulation model, calibration is performed in two stages: (a) building shell calibration with the HVAC system replaced by an ideal system that meets the loads (b) HVAC system calibration with the building shell and all internal loads replaced by a box with only process loads. In the first stage, EPE identifies a small number of high-level heat flows in the energy balance, calculates them with specifically tailored individual driving functions, introduces physically significant parameters to best accomplish energy balance, and, estimates the parameters and their uncertainty bounds. Calibration is thus done with corrective heat flows without any arbitrary tuning of input parameters. Calibration accuracy is enhanced by machine learning of the residual errors. The EPE methodology is demonstrated by means of: a synthetic building and an actual 75,000 sq. ft. building in Pennsylvania. Future work needed for widespread application is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chord length sampling method for analyzing VHTR unit cells in continuous energy simulations

The chord length sampling method (CLS) is studied in the continuous energy simulations by applying it to analyzing two types of Very High Temperature Gas-cooled Reactor (VHTR) unit cells: the fuel compact cell in the prismatic type VHTR and the fuel pebble cell in the pebble-bed type VHTR. Infinite multiplication factors of the unit cells are calculated by the CLS and compared to the benchmark simulations at different volume packing fractions from 5% to 30%. It is shown that the accuracy of the CLS is affected by the boundary effect, which is induced by the CLS procedure itself and results in a reduction in the total volume packing fraction of the fuel particles. To mitigate the boundary effect, three correction schemes based on the research of 1) Murata et al. 2) Ji and Martin 3) Griesheimer et al. are used to improve the accuracy by applying a corrected value of the volume packing fraction to the CLS. These corrected values are calculated based on 1) a simple linear relationship, 2) an iterative self-consistent simulation correction method, and 3) a theoretically derived non-linear relationship, respectively. The CLS simulation using the corrected volume packing fraction shows excellent improvements in the infinite multiplication factors for the VHTR unit cells. Ji and Martin's self-consistent correction method shows the best improvement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗