Search NASASearch

SEARCH · Search NASA

Results for “EnergyPlus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior

MCP-enabled agentic AI workflow for building energy modelling: framework and use cases

Traditional building energy modelling workflows remain labor-intensive and error-prone, requiring specialized expertise that limits broader adoption. This paper introduces a novel Model Context Protocol (MCP)-enabled framework that connects AI assistants to EnergyPlus through MCP, a standardized interface for tool invocation and context management. Two complementary integration paradigms are presented and compared: conversational integration, where users interact through natural language while an AI assistant orchestrates MCP tools on demand, and agentic workflow integration, where specialized agents coordinate autonomously to complete multi-step tasks. Using an experimental testbed for residential buildings, the end-to-end workflows are demonstrated. The conversational approach reduced typical inspection and modification tasks from 1-2 h to under 15 min, while maintaining full transparency through visible tool invocations. The agentic approach automated parametric analysis. These demonstrations establish MCP as a foundational layer for AI-assisted building energy modelling, enabling natural language interactions with simulation tools while preserving professional oversight and decision-making authority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY

Using Time Series Data Products to Support ASHRAE’s Historic and Future Climate Data Needs through NASA’s POWER Web Services

To address the data needs for resilience and sustainability of building systems within ASHRAE, the NASA Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data on a long-term, global scale. Solar data from several NASA projects and meteorological data from NASA assimilation models have been reformatted and disseminated to the public via a user friendly web GIS-enabled based data portal (https://power.larc.nasa.gov) in selectable data formats, immediately amenable to key industry wide decision support tools such as EnergyPlus. Time series of potential climate conditions from downscaled climate simulations are being made available for similar statistics and formats. An emphasis is placed upon obtaining and utilizing time series data to conduct analysis of building system performance for current and planning building systems for energy savings and greenhouse gas emissions. This presentation has the learning following learning objectives for the ASHRAE community: 1) Learn how NASA POWER’s web service suite can provide supplementary solar and surface meteorological data parameters, including a discussion of uncertainty. 2) Learn how downscaled climate scenario information can be provided to evaluate potential future requirements. The presentation is part of a forum entitled, "Weather Data for Large-Scale Building Energy Modeling".

time series

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID