Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error field control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Classical Non-Markovian Noise in Symmetry-Preserving Quantum Dynamics

In quantum dynamics, symmetries are vital for identifying and assessing conserved quantities that govern the evolution of a quantum system. When promoted to the open quantum system setting, dynamical symmetries can be negatively altered by system-environment interactions, thus, complicating their analysis. Previous work on noisy symmetric quantum dynamics has focused on the Markovian setting, despite the ubiquity of non-Markovian noise in a number of widely used quantum technologies. Here, in this Letter, we develop a framework for quantifying the impact of non-Markovian noise on symmetric quantum evolution via root space decompositions and the filter function formalism. We demonstrate analytically that symmetry-preserving noise maintains the symmetric subspace, while nonsymmetric noise leads to highly specific leakage errors that are block diagonal in the symmetry representation. We support our findings with numerical studies of a transverse-field Ising model and a quantum error detecting code subject to spatiotemporally correlated multiaxis noise. Our results are broadly applicable, providing new analytic insights into the control and characterization of open quantum system dynamics.

decoherence↗

Non-disruptive error field identification based on magnetic island healing

Here a technique to identify intrinsic error fields (EFs) in tokamaks with minimized risk of disruption is demonstrated on the DIII-D tokamak. The method extends the conventional driven magnetic island ‘compass scan’ approach by modifying asynchronous control waveforms to enable prompt healing of the island instability. Healing of the island is achieved by reducing the imposed non-axisymmetric coil current and raising the density (here via gas fueling). The method is also shown to support multiple island threshold measurements per pulse, thus reducing the number of dedicated pulses necessary to conduct an EF identification. Non-linear modeling with the TM1 code reproduces the experimental results and approximately recovers the critical density required for island healing. Island healing is explained in the non-linear modeling by an increase in the viscous coupling between the static island and the nearby flowing plasma, thus healing the island as it accelerates into the plasma frame. Due to both simplicity and risk minimization, this technique is suitable for plasma-based EF identification in the early commissioning stages of future disruption-averse tokamaks such as ITER and SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimetry-Enhanced Imaging towards Autonomous Solar Field and Receiver Inspections

During the typical operation of a Concentrating Solar Power (CSP) plant, a large portion of the energy (~45%) can be lost due to various imperfect conditions, such as blocking, shading, mirror soiling, tracking and canting errors, etc. It is necessary to develop efficient and effective field inspection technology to optically survey and characterize a CSP field, which can be used as an input for autonomous control, maintenance scheduling and spot repair whenever necessary to maximize the overall efficiency of the plant. In this project, We aim to apply polarimetric imaging for CSP collector and receiver inspection and develop polarimetric drone cameras (via integrating polarimetric imagers onto drones) for autonomous field inspection in CSP plants.

14 SOLAR ENERGY↗

Understanding and control of Zener pinning via phase field and ensemble learning

Zener pinning refers to the dispersion of fine particles which influences grain size distribution via movement of grain boundaries in a polycrystalline material. Grain size distribution in polycrystals has a significant impact on their properties including physical, chemical, mechanical, and optical to name a few. We explore the use of Phase-field modeling and machine-learning techniques to understand and improve the control of grain size distribution via Zener pinning in polycrystalline materials. We develop a machine learning model that determines the relative importance of various parameters to exercise microstructure control via Zener pinning. Our workflow combines high-throughput phase-field simulations and machine learning to address the computational bottlenecks associated with large-scale simulations as well as identify features necessary for microstructure control in polycrystals. A random forest (RF) regression model was developed to predict grain sizes based on five Phase-field model parameters, achieving an average prediction error of 0.72 nm for the training data and 1.44 nm for the test data. The importance of the input parameters is analyzed using the SHapley Additive exPlanations (SHAP) approach which reveals that diffusivity, volume fraction, and particle diameter are the most important parameters in determining the final grain size. These findings will allow us to select the best second-phase particles, optimize grain size distributions and thus design microstructures with the desired properties. The developed method is a highly versatile and generalizable approach that can be used to assess the combined effects of individual features in the presence of multiple variables.

36 MATERIALS SCIENCE↗

Analysis of Integrated Vapor Transport Biases

Abstract High-fidelity analyses and forecasts of integrated vapor transport (VT) are central to the study of Earth’s hydrological cycle as well as high-impact phenomena such as monsoons and atmospheric rivers. The impact of the in-line analysis correction-based additive inflation (ACAI) on IVT biases and forecast errors is examined within the Navy Earth System Prediction Capability (Navy ESPC) global coupled system. The ACAI technique uses atmospheric analysis corrections from the data assimilation system to approximate model bias and as a representation of stochastic model error to simultaneously reduce systematic and random errors and improve ensemble performance. ACAI reduces the global average magnitude of the 7- and 14-day IVT bias by 16%–17% during Northern Hemisphere summer, reaching 70% reductions in some tropical regions. The global average IVT bias reduction is similar to the bias reduction for low-level wind speed bias and considerably smaller than the bias reduction in total precipitable water. The localized regions where ACAI increases IVT bias occur where the control IVT biases change sign and structure with increasing forecast lead time, such as the South Asian monsoon region. Substituting analyzed wind or moisture fields for the forecast fields when calculating the forecast IVT confirms that, on average, wind errors dominate the IVT error calculation in the tropics, although wind and moisture error contributions are comparable in the extratropics. The existence of regions where using either analyzed winds or analyzed moisture increases IVT bias or mean absolute error reveals areas with compensating errors.

Reynolds, Carolyn A.↗

Prediction of Alpha-Particle-Immune Gate-All-Around Field-Effect Transistors (GAA-FET) Based SRAM Design

Alpha particles are known to be a major source of particles creating soft errors in semiconductor devices, such as content flipping in Static Random-Access Memory (SRAM). Recent advancements in transistor nodes have led to the introduction of Gate-All-Around Field Effect Transistors (GAA-FETs), which have better gate control, thus better electrostatics. Moreover, the introduction of bottom dielectric isolation (BDI) eliminates substrate leakage and thus is expected to enhance its radiation hardness. It is thus important to explore if one can design an SRAM that is completely radiation-hard to alpha particles. In this paper, using 3D Technology Computer-Aided-Design (TCAD) simulations, we show that it is possible to design an SRAM using GAA-FET technology so that it is immune to single alpha particle radiation error. In other words, with the design, there will be no single-event upset (SEU) due to alpha particles. We first use ab initio calculations in PHITS to show that there is a maximum linear energy transfer (LET), LET max , for the alpha particle in Si and Si x Ge 1-x . Based on that, by de signing a sub-7nm GAA-FET-based SRAM with BDI, we show that the SRAM does not flip even if the particle strike is in the worst-case scenario for LET > LET max .

42 ENGINEERING↗

Stability and Control of Burning Tokamak Plasmas with Resistive Walls (Final Report)

Work supported by the grant, "Stability and Control of Burning Tokamak Plasmas with Resistive Walls" in the period Aug 2017 to 2023 can be cast in three general categories: (1) linear tearing regimes and the effects on the response to error fields and resistive walls: (2) nonlinear tearing modes in the presence of error fields, with locking; and (3) energetic particle effects. In the first category, we have completed a study of tearing mode regimes with extended MHD effects, including parallel dynamics and toroidal effects, notably favorable average curvature. This work has been presented at the 2018 Sherwood Conference. This work has been published in the ArXiv and is being prepared for publication in Physics of Plasmas. A systematic study of shaping in a tokamak plasma with resistive tearing layers and a resistive wall has been presented in the PhD dissertation by Dov Rhodes, a student of Andrew Cole at Columbia University. John Finn was on Rhodes's PhD committee, and was a co-author of a paper published in Physics of Plasmas on that work. A detailed study of nonlinear tearing modes in the presence of finite beta, favorable average curvature, and an error field has been nearly completed. In this study it was found that the response to an error field with real frequency a tearing layer agreed with analytic results, and that tearing mode saturation by flattening of the current profile as well as destabilization due to flattening of the pressure profile were important factors in the locking process. This work was presented at the 2017 APS/DPP Conference and at the 2018 Sherwood Conference. The effects of energetic ions on tearing modes was presented at the 2017 APS/DPP Conference and in the PhD dissertation of Michael Halfmoon. John Finn served as a committee member on Halfmoon's PhD committee. Extensions to this work including two fluid effects were performed and presented at the APS/DPP Conference in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Resonant Magnetic Perturbations on the Toroidal Location of the Runaway Electron Final Loss Strike Point

It is demonstrated that the peak toroidal impact phase of the post-disruption runaway electrons (REs) can be varied shot-to-shot by means of applied static non-axisymmetric (3D) magnetic fields, or resonant magnetic perturbations (RMPs). In the experiments, high-current (500 kA), purged RE plateaus (i.e. low impurity post-disruption plasmas with current carried completely by REs) were terminated on the DIII-D tokamak center post (CP). The global toroidal impact peak of the REs appears to be dominantly set by the toroidal phase of a wall-locked tearing mode, typically (m/n) = (2/1), but sometimes (m/n) = (3/2). In the absence of external RMP, the locked mode reliably locks close to a preferred toroidal phase Φ ≃ 75◦ probably set by intrinsic error fields. With applied RMP, the locked mode and RE impact phase is pushed to a new location. When the tearing mode is (m/n) = (2/1), the phase is well controlled and tracks the applied RMP phase, but in the case of an (m/n) = (3/2) tearing mode, the new phase location is not well controlled. These results could have application in ITER and other fusion power plant (FPP) - sized tokamaks as a method for spreading disruption first wall damage from REs

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tauberian-Cardy formula with spin

We prove a $2$ dimensional Tauberian theorem in context of $2$ dimensional conformal field theory. The asymptotic density of states with conformal weight $(h,\bar{h})\to (\infty,\infty)$ for any arbitrary spin is derived using the theorem. We further rigorously show that the error term is controlled by the twist parameter and insensitive to spin. The sensitivity of the leading piece towards spin is discussed. We identify a universal piece in microcanonical entropy when the averaging window is large. An asymptotic spectral gap on $(h,\bar{h})$ plane, hence the asymptotic twist gap is derived. We prove an universal inequality stating that in a compact unitary $2$D CFT without any conserved current $Ag\leq \frac{\pi(c-1)r^2}{24}$ is satisfied, where $g$ is the twist gap over vacuum and $A$ is the minimal "areal gap", generalizing the minimal gap in dimension to $(h',\bar{h}')$ plane and $r=\frac{4\sqrt{3}}{\pi}\simeq 2.21$. We investigate density of states in the regime where spin is parametrically larger than twist with both going to infinity. Moreover, the large central charge regime is studied. We also probe finite twist, large spin behavior of density of states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error-Free and Current-Driven Synthetic Antiferromagnetic Domain Wall Memory Enabled by Channel Meandering

We propose a new type of energy-efficient multi-bit magnetic memory based on current-driven, field-free, controlled domain wall motion. A meandering domain wall channel with precisely interspersed pinning regions provides the multi-bit capability of a magnetic tunnel junction memory. The magnetic free layer of the memory device has perpendicular magnetic anisotropy (PMA) and interfacial Dzyaloshinskii-Moriya interaction (DMI) so that spin-orbit torques (SOTs) induce efficient domain wall motion. Using micromagnetic simulations, we find two different cell designs: two-way switching and four-way switching. The memory cell design choices and the physics of pinning mechanisms are discussed in detail. Furthermore, we show that switching reliability and speed may be significantly improved by replacing the ferromagnetic free layer with a synthetic antiferromagnetic (SAF) layer. Switching behavior and material choices will be discussed for the two memory implementations.

magnetic domain wall↗

A hybrid neural architecture: Online attosecond x-ray characterization

The emergence of high-repetition-rate x-ray free-electron lasers (XFELs), such as SLAC’s LCLS-II, serves as our canonical example for autonomous controls that necessitate high-throughput diagnostics paired with streaming computational pipelines capable of single-shot analysis with extremely low latency. We present the deterministic characterization with an integrated parallelizable hybrid resolver architecture, a hybrid machine learning framework designed for fast, accurate analysis of XFEL diagnostics using angular streaking-based sinogram images. This architecture integrates convolutional neural networks and bidirectional long short-term memory models to denoise input, identify x-ray sub-spike features, and extract sub-spike relative delays with sub-30 attosecond temporal resolution. Deployed on low-latency hardware, it achieves over 10 kHz throughput with 168.3 μs inference latency, indicating scalability to 14 kHz with field-programmable gate array integration. By transforming regression tasks into classification problems and leveraging optimized error encoding, we achieve high precision with low-latency performance that is critical for real-time streaming event selection and experimental control feedback signals. This represents a key development in real-time control pipelines for next-generation autonomous science, generally, and high repetition-rate x-ray experiments in particular.

Accelerator Physics (physics.acc-ph)↗

TopoSZ: Preserving Topology in Error-Bounded Lossy Compression

Existing error-bounded lossy compression techniques control the pointwise error during compression to guarantee the integrity of the decompressed data. However, they typically do not explicitly preserve the topological features in data. When performing post hoc analysis with decompressed data using topological methods, preserving topology in the compression process to obtain topologically consistent and correct scientific insights is desirable. In this paper, we introduce TopoSZ, an error-bounded lossy compression method that preserves the topological features in 2D and 3D scalar fields. Specifically, we aim to preserve the types and locations of local extrema as well as the level set relations among critical points captured by contour trees in the decompressed data. The main idea is to derive topological constraints from contour-tree-induced segmentation from the data domain, and incorporate such constraints with a customized error-controlled quantization strategy from the SZ compressor (version 1.4). In conclusion, our method allows users to control the pointwise error and the loss of topological features during the compression process with a global error bound and a persistence threshold.

97 MATHEMATICS AND COMPUTING↗

Controlling the size of non-axisymmetric magnetic footprints using resonant magnetic perturbations

The structure of the non-axisymmetric heat load distribution at the divertor plates is determined not only by the toroidal but also from the poloidal spectrum of non-axisymmetric field perturbations. Whether they are intrinsic, like error fields, or they are applied through 3D coils, the non-axisymmetric fields produce complex 3D edge magnetic topologies (footprints) that alter the properties of the heat and particle flux distributions on the divertor target plates. In this manuscript, a study of the impact of applied 3D field poloidal spectrum on the footprint size and structure is done for the DIII-D tokamak using the resistive MHD code M3D-C1 coupled with the field line tracing code TRIP3D. To resolve the impact of the poloidal spectrum of the magnetic perturbation, the relative phase of the two rows of in-vessel 3D coils used to produce both a n = 2 and a n = 3 perturbation is varied, where n is the toroidal harmonic of the magnetic perturbation. This shows that the largest footprint is predicted when the relative phase of the two rows is close to zero, which is also where the resonant coupling with the plasma is maximized. These results suggest that it will be challenging to decouple the footprint size from the requisite resonant coupling for RMP–ELM control. The correlation between the measured heat load and particle flux distributions at the outer divertor plates in DIII-D and the magnetic measurements is in good agreement with the predicted dependence of the magnetic footprint size on the amplitude of the resonant component of the plasma response.

3D fields↗

Digitizing Today’s Buildings in the Real World: Lessons from Field Demonstrations

Digital twins, created by generating a virtual replica of a building, enable safe evaluation of operational scenarios and applications like fault detection and diagnosis and advanced controls. However, a prerequisite is the creation of a machine-readable digital representation of a building, currently hindered by fragmented information scattered across mechanical drawings, point lists, and natural language sequences. As a result, digital twin development remains labor-intensive, error-prone, and difficult to validate. To address these challenges, two efforts from ASHRAE aim to support the digitalization of buildings. ASHRAE s223 establishes a semantic model of buildings, representing system components, configuration, and data sources. ASHRAE s231 defines a vendor-neutral programming language for expressing their control logic. As the industry evaluates implementing them in their products, understanding the challenges that vendors and implementers may face is crucial. In this paper, we present findings and lessons learned from field demonstrations in five buildings that implemented control applications using ASHRAE s223 and s231. The demonstrations highlight how semantic modeling and formalized control descriptions can significantly reduce software development time, manual point mapping, and hard-coding. Beyond time efficiency, they enable reliable automation by minimizing human interpretation and providing a means for consistency across projects. We describe the processes and best practices for model creation and model usage, from translating heterogeneous building documentation into semantic representations to implementing control logic in real-world systems. Finally, we discuss the challenges that persist, including integration with legacy software environments, gaps in interoperability, and the level of expertise still required to effectively leverage semantic models.

Prakash, Anand Krishnan↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

Scalable photonic integrated circuits for high-fidelity light control

Advances in laser technology have driven discoveries in atomic, molecular, and optical (AMO) physics and emerging applications, from quantum computers with cold atoms or ions, to quantum networks with solid-state color centers. This progress is motivating the development of a new generation of optical control systems that can manipulate the light field with high fidelity at wavelengths relevant for AMO applications. These systems are characterized by criteria: (C1) operation at a design wavelength of choice in the visible (VIS) or near-infrared (IR) spectrum, (C2) a scalable platform that can support large channel counts, (C3) high-intensity modulation extinction and (C4) repeatability compatible with low gate errors, and (C5) fast switching times. Here, we provide a pathway to address these challenges by introducing an atom control architecture based on VIS-IR photonic integrated circuit (PIC) technology. Based on a complementary metal–oxide–semiconductor fabrication process, this atom-control PIC (APIC) technology can meet system requirements (C1)–(C5). As a proof of concept, we demonstrate a 16-channel silicon-nitride-based APIC with (5.8±0.4)ns response times and >30dB extinction ratio at a wavelength of 780 nm.

Menssen, Adrian J.↗

Adaptive immersed isogeometric level-set topology optimization

Here, this paper presents for the first time an adaptive immersed approach for level-set topology optimization using higher-order truncated hierarchical B-spline discretizations for design and state variable fields. Boundaries and interfaces are represented implicitly by the iso-contour of one or multiple level-set functions. An immersed finite element method, the eXtended IsoGeometric Analysis, is used to predict the physical response. The proposed optimization framework affords different adaptively refined higher-order B-spline discretizations for individual design and state variable fields. The increased continuity of higher-order B-spline discretizations together with local refinement enables direct control over the accuracy of the representation of each field while simultaneously reducing computational cost compared to uniformly refined discretizations. A flexible mesh adaptation strategy enables local refinement based on geometric measures or physics-based error indicators. These adaptive discretization and analysis approaches are integrated into gradient-based optimization schemes, evaluating the design sensitivities using the adjoint method. Numerical studies illustrate the features of the proposed framework with static, linear elastic, multi-material, two- and three-dimensional problems. The examples provide insight into the effect of refining the design variable field on the optimization result and the convergence rate of the optimization process. Using coarse higher-order B-spline discretizations for level-set fields promotes the development of smooth designs and suppresses the emergence of small features. Moreover, adaptive mesh refinement for state variable fields results in a reduction of overall computational cost. Higher-order B-spline discretizations are especially interesting when evaluating gradients of state variable fields due to their higher inter-element continuity.

36 MATERIALS SCIENCE↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗