Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exercise Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Determinants of Time to Fatigue during Non-Motorized Treadmill Exercise

Treadmill exercise is commonly used for aerobic and anaerobic conditioning. During non-motorized treadmill exercise, the subject must provide the power necessary to drive the treadmill belt. The purpose of this study was to determine what factors affected the time to fatigue on a pair of non-motorized treadmills. Twenty subjects (10 males/10 females) attempted to complete five minutes of locomotion during separate trials at 3.22, 4.83, 6.44, 8.05, 9.66, and 11.27 km (raised dot) h(sup -1). Total exercise time (less than or equal to 5 min) was recorded. Exercise time was converted to the amount of 15 second intervals completed. Peak oxygen uptake (VO2) was measured using a graded exercise test on a standard treadmill, and anthropometric measures were collected from each subject before entering into the study. A Cox proportional hazards regression model was used to determine significant predictive factors in a multivariate analysis. Non-motorized treadmill speed and absolute peak VO2 were found to be significant predictors of exercise time, but there was no effect of anthropometric characteristics. Gender was found to be a predictor of treadmill time, but this was likely due to a higher peak VO2 in males than in females. These results were not affected by the type of treadmill tested in this study. Coaches and therapists should consider the cardiovascular fitness of an athlete or client when prescribing target speed since these factors are related to the total exercise time than can be achieved on a non-motorized treadmill.

DeWitt, John K.↗

T wave alternans during exercise and atrial pacing in humans

INTRODUCTION: Evidence is accumulating that microvolt T wave alternans (TWA) is a marker of increased risk for ventricular tachyarrhythmias. Initially, atrial pacing was used to elevate heart rate and elicit TWA. More recently, a noninvasive approach has been developed that elevates heart rate using exercise. METHODS AND RESULTS: In 30 consecutive patients with a history of ventricular tachyarrhythmias, the spectral method was used to detect TWA during both atrial pacing and submaximal exercise testing. The concordance rate for the presence or absence of TWA using the two measurement methods was 84%. There was a patient-specific heart rate threshold for the detection of TWA that averaged 100 +/- 14 beats/min during exercise compared with 97 +/- 9 beats/min during right atrial pacing (P = NS). Beyond this threshold, there was a significant and comparable increase in level of TWA with decreasing pacing cycle length and increasing exercise heart rates. CONCLUSIONS: The present study is the first to demonstrate that microvolt TWA can be assessed reliably and noninvasively during exercise stress. There is a patient-specific heart rate threshold beyond which TWA continues to increase with increasing heart rates. Heart rate thresholds for the onset of TWA measured during atrial pacing and exercise stress were comparable, indicating that heart rate alone appears to be the main factor of determining the onset of TWA during submaximal exercise stress.

NASA Discipline Regulatory Physiology↗

A comparison between computer-controlled and set work rate exercise based on target heart rate

Two methods are compared for observing the heart rate (HR), metabolic equivalents, and time in target HR zone (defined as the target HR + or - 5 bpm) during 20 min of exercise at a prescribed intensity of the maximum working capacity. In one method, called set-work rate exercise, the information from a graded exercise test is used to select a target HR and to calculate a corresponding constant work rate that should induce the desired HR. In the other method, the work rate is controlled by a computer algorithm to achieve and maintain a prescribed target HR. It is shown that computer-controlled exercise is an effective alternative to the traditional set work rate exercise, particularly when tight control of cardiovascular responses is necessary.

Pratt, Wanda M.↗

Supine Lower Body Negative Pressure Exercise Maintains Upright Exercise Capacity in Male Twins during 30 Days of Bed Rest

Exercise capacity is reduced following both short and long duration exposures to microgravity. We have shown previously that supine lower body negative pressure with exercise (LBNP(sub ex) maintains upright exercise capacity in men after 5d and 15d bed rest, as a simulation of microgravity. We hypothesized that LBNP(sub ex) would protect upright exercise capacity (VO2pk) and sprint performance in eight sets of identical male twins during a 30-d bed rest. Twins within each set were randomly assigned to either a control group (CON) who performed no exercise or to an exercise group (EX) who performed a 40-min interval (40-80% pre-BR VO2pk) LBNP(sub ex) (55+/-4 mmHg) exercise protocol, plus 5 min of resting LBNP, 6 d/wk. LBNP produced footward force equivalent to 1.0- 1.2 times body weight. Pre- and post-bed rest, subjects completed an upright graded exercise test to volitional fatigue and sprint test of 30.5 m. After bed rest, VO2pk was maintained in the EX subjects (-3+/-3%), but was significantly decreased in the CON subjects (-24+/-4%). Sprint time also was increased in the CON subjects (24+/-8%), but maintained in the EX group (8+/-2%). The performance of a supine, interval exercise protocol with LBNP maintains upright exercise capacity and sprint performance during 30 d of bed rest. This exercise countermeasure protocol may help prevent microgravity-induced deconditioning during long duration space flight.

Lee, Stuart M. C.↗

Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data.

Dolezal, B. A.↗

Cardiopulmonary Responses to Supine Cycling during Short-Arm Centrifugation

The purpose of this study was to investigate cardiopulmonary responses to supine cycling with concomitant +G(sub z) acceleration using the NASA/Ames Human Powered Short-Arm Centrifuge (HPC). Subjects were eight consenting males (32+/-5 yrs, 178+/-5 cm, 86.1+/- 6.2 kg). All subjects completed two maximal exercise tests on the HPC (with and without acceleration) within a three-day period. A two tailed t-test with statistical significance set at p less than or equal to 0.05 was used to compare treatments. Peak acceleration was 3.4+/-0.1 G(sub z), (head to foot acceleration). Peak oxygen uptake (VO2(sub peak) was not different between treatment groups (3.1+/-0.1 Lmin(exp -1) vs. 3.2+/-0.1 Lmin(exp -1) for stationary and acceleration trials, respectively). Peak HR and pulmonary minute ventilation (V(sub E(sub BTPS))) were significantly elevated (p less than or equal to 0.05) for the acceleration trial (182+/-3 BPM (Beats per Minute); 132.0+/-9.0 Lmin(exp -1)) when compared to the stationary trial (175+/-3 BPM; 115.5+/-8.5 Lmin(exp -1)). Ventilatory threshold expressed as a percent of VO2(sub peak) was not different for acceleration and stationary trials (72+/-2% vs. 68+/-2% respectively). Results suggest that 3.4 G(sub z) acceleration does not alter VO2(sub peak) response to supine cycling. However, peak HR and V(sub E(sub BTPS)) response may be increased while ventilatory threshold response expressed as a function of percent VO2(sub peak) is relatively unaffected. Thus, traditional exercise prescription based on VO2 response would be appropriate for this mode of exercise. Prescriptions based on HR response may require modification.

Vener, J. M.↗

Aerobic Capacity Following Long Duration International Spaces Station (ISS) Missions: Preliminary Results

Maximum oxygen uptake (VO2max) is reduced immediately following space flights lasting <15 d, but has not been measured following long-duration missions. The purpose of this study is to measure VO2max and maximum work rate (WRmax) data from astronauts following ISS flights (91 to 188 d). Methods: Five astronauts [3 M, 2 F: 47+/-6 yr, 174+/-6 cm, 71.9+/-10.9 kg (mean +/- SD)] have participated in the study. Subjects performed upright cycle exercise tests to symptom-limited maximum. An initial test was done approx.270 d before flight to establish work rates for subsequent tests. Subsequent tests, conducted approx.45 d before flight and repeated on the first or second day (R+1/2) and at approx.10 d (R+10) following landing, consisted of 3 5 min stages designed to elicit 25%, 50%, and 75% of preflight VO2max, followed by 25 W(dot)/min increases. VO2, WR, and heart rate (HR) were measured using the ISS Portable Pulmonary Function System [Damec, Odense, DK]. Descriptive statistics are reported. Results: On R+1/2 mean VO2max decreased compared to preflight (Pre: 2.98+/-0.99, R+1/2: 2.63+/-0.56 L(dot)/min); 4 of 5 subjects demonstrated a loss of > 6%. WRmax also decreased on R+1/2 compared to preflight (Pre: 245+/-69, R+1/2: 210+/-45 W). On R+10, VO2max was 2.86+/-0.62 L(dot)/min, with 2 subjects still demonstrating a loss of > 6% from preflight. WRmax on R+10 was 240+/-49 W. HRmax did not change from pre to post-flight. Conclusions: These preliminary results, from the first 5 of 12 planned subjects of an ongoing ISS study, suggest that the majority of astronauts will experience a decrease in VO2max after long-duration space-flight. Interestingly, the two astronauts with the highest preflight VO2max had the greatest loss on R+1/2, and the astronaut with the lowest preflight VO2max increased by 13%. Thus, maintenance of VO2max may be more difficult in astronauts who have a high aerobic capacity, perhaps requiring more intense in-flight exercise countermeasure prescriptions.

Moore, Alan D.↗

Densitography - A new method for evaluation of cardiac performance of rest and during exercise.

The validity of the densitographic curves obtained from the pinna of the ear for measuring the systolic intervals has been investigated in 28 subjects. This technique is found to permit the performance of noninvasive physiologic studies during physical activities, exercise tests, flight conditions, and probably long-term monitoring of critically ill patients. Densitographic curves constitute an excellent substitute by which to measure time-base intervals of the cardiac cycle when the carotid pulse tracing is not available.

Chirife, R.↗

The NASA-USPHS Health Evaluation and Enhancement Program

An exercise program was initiated to assess the feasibility of an on the job health evaluation and enhancement program, as well as to identify the factors which influenced volunteering, adherence, and effectiveness of the program. The program was utilized by 237 of the 998 eligible Federal employees, with a mean attendance of 1.3 days per week. Those who volunteered perceived a need for increased physical activity, felt they had sufficient time to participate, and derived subjective as well as objective benefits. Significant improvements were found in heart rate response to the standard exercise test, body weight, skinfold measurements, and triglycerides. A consistent relationship was found between subjectively reported effects of the program on work, health habits, and behavior, and improvement in cardiovascular function, based on treadmill performance. Numerous personal and programmatic factors influencing volunteering and participation were identified.

Durbeck, D. C.↗

The National Aeronautics and Space Administration-U.S. Public Health Service Health Evaluation and Enhancement Program - Summary of results.

An exercise program was initiated in a federal agency to assess the feasibility of such a program, and to identify the factors that influenced joining, adherence to, and effectiveness of the program. The program was utilized by 237 of the 998 eligible federal employees; mean attendance rate was 1.3 days/week. Those who volunteered perceived a need for increased physical activity, believed they had sufficient time to participate and derived subjective as well as objective benefits. Significant improvements were found in heart rate response to the standard exercise test, body weight, skinfold measurements and triglyceride levels.

Durbeck, D. C.↗

Pulmonary function evaluation during and following Skylab space flights

Previous experience during the Apollo postflight exercise testing indicated no major changes in pulmonary function. Although pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic environments, few studies have dealt with normoxic environments at reduced total pressure as encountered during the Skylab missions. Forced vital capacity was measured during the preflight and postflight periods of the Skylab 2 mission. Initial in-flight measurements of vital capacity were obtained during the last two weeks of the second manned mission (Skylab 3). Comprehensive pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination, closing volume, vital capacity, and forced vital capacity and its derivatives. In addition, comprehensive in-flight vital capacity measurements were made during the Skylab 4 mission. Vital capacity was decreased slightly during flight in all Skylab 4 crewmen. No major preflight to postflight changes were observed in the other parameters.

Sawin, C. F.↗

Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions

Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

Sawin, C. F.↗

Pulmonary function evaluation during and following Skylab space flights

Cardiac output measurements were made in the laboratory during preflight and postflight exercise tests. Due to the magnitude of decreases in cardiac output following the first and second manned Skylab missions and because the method used is based upon normal pulmonary function, it was decided to perform more thorough pulmonary function screening in conjunction with the final and longest duration Skylab mission. This paper summarized pulmonary function data obtained during all three Skylab missions.

Sawin, C. F.↗

Induced venous pooling and cardiorespiratory responses to exercise after bed rest

Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

Convertino, V. A.↗

Effect of aerobic capacity on Lower Body Negative Pressure (LBNP) tolerance in females

This investigation determined whether a relationship exists in females between: (1) aerobic capacity and Lower Body Negative Pressure (LBNP); and (2) aerobic capacity and change in LBNP tolerance induced by bed rest. Nine females, age 27-47 (34.6 plus or minus 6.0 (Mean plus or minus SD)), completed a treadmill-graded exercise test to establish aerobic capacity. A presyncopal-limited LBNP test was performed prior to and after 13 days of bed rest at a 6 deg head-down tilt. LBNP tolerance was quantified as: (1) the absolute level of negative pressure (NP) tolerated for greater than or equal to 60 sec; and (2) Luft's Cumulative Stress Index (CSI). Aerobic capacity was 33.3 plus or minus 5.0 mL/kg/min and ranged from 25.7 to 38.7. Bed rest was associated with a decrease in NP tolerance (-9.04 1.6 kPa(-67.8 plus or minus 12.0 mmHg) versus -7.7 1.1 kPa(-57.8 plus or minus 8.33 mmHg); p = 0.028) and in CSI (99.4 27.4 kPa min(745.7 plus or minus 205.4 mmHg min) versus 77.0 16.9 kPa min (577.3 plus or minus mmHg min); p = 0.008). The correlation between aerobic capacity and absolute NP or CSI pre-bed rest did not differ significantly from zero (r = -0.56, p = 0.11 for NP; and r = -0.52, p = 0.16 for CSI). Also, no significant correlation was observed between aerobic and pre- to post-rest change for absolute NP tolerance (r = -0.35, p = 0.35) or CSI (r = -0.32, p = 0.40). Therefore, a significant relationship does not exist between aerobic capacity and orthostatic function or change in orthostatic function induced by bed rest.

Moore, Alan D., Jr.↗

Variability of prediction of maximal oxygen concumption on the cycle ergometer using standard equations

Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.

Greenisen, Michael C.↗

Effect of resistance training on muscle use during exercise

This study examined the effect of resistance training on exercise-induced contrast shift in magnetic resonance (MR) images. It was hypothesized that a given load could be lifted after training with less muscle showing contrast shift, thereby suggesting less muscle was used to perform the exercise. Nine males trained the left quadriceps femoris (QF) muscle 2 days/wk for 9 wk using 3-6 sets of 12 knee extensions each day. The right QF served as a control. Exercise-induced contrast shifts in MR images evoked by each of three bouts of exercise (5 sets of 10 knee extensions with a load equal to 50, 75, and 100% of the maximum pretraining load that could be lifted for 5 sets of 10 repetitions) were quantified pre- and posttraining. MR image contrast shift was quantified by determining QF cross-sectional area (CSA) showing increased spin-spin relaxation time. One repetition maximum increased 14% in the left trained QF and 7% in the right untrained QF. Left QF CSA increased 5%, with no change in right QSF CSA. Left QF CSA showing contrast shift was less after each bout of the exercise test posttraining. This was also true, to a lesser extent, for the right QF at the higher two loads. The results suggest that short-term resistance training reduces MR image contrast shift evoked by a given effort, thereby reflecting the use of less muscle to lift the load. Because this response was evident in both trained and contralateral untrained muscle, neural factors are suggested to be responsible. The consequence of this adaptation could be to increase 'stress' per unit area of active muscle during the course of training and thereby evoke hypertrophy.

Ploutz, Lori L.↗