At least 55 records · Page 3

An Improved Plastically Dilatant Unified Viscoplastic Constitutive Formulation for Multiscale Analysis of Polymer Matrix Composites Under High Strain Rate Loading

Polymer matrix composites are commonly used to fabricate energy-absorbing structures expected to experience impact loading. As such, a detailed understanding of the dynamic response of the constituent materials is necessary. Since the rate, temperature, and pressure dependence of carbon fiber reinforced polymer matrix composites are primarily manifestations of the rate, temperature, and pressure dependence of the polymer matrix, it is crucial that the constitutive behavior of the matrix be accurately characterized. In this work, an existing unified viscoplastic constitutive formulation is extended to ensure thermodynamic consistency and to more accurately account for the tension-compression asymmetry observed in the response of polymeric materials. A new plastic potential function is proposed, and elementary loading conditions are utilized to determine relations between model constants to ensure nonnegative plastic dissipation, a necessary thermodynamic requirement. Expressions for plastic Poisson’s ratios are derived and are bounded by enforcing nonnegative plastic dissipation. The model is calibrated against available experimental data from tests conducted over a range of strain rates, temperatures, and loading cases on a representative thermoset epoxy; good correlation between simulations and experimental data is obtained. Temperature rises due to the conversion of plastic work to heat are computed via the adiabatic heat energy equation. The viscoplastic polymer model is then used as a constitutive model in the generalized method of cells micromechanics theory to investigate the effects of matrix adiabatic heating on the high strain rate response of a unidirectional composite. The thermodynamic consistency of the model ensures plastic dissipation can only cause an increase in temperature. Simulation results indicate that significant thermal softening due to the conversion of plastic work to heat is observed in the composite for matrix dominated deformation modes.

Impact loading↗

Spectral radiance measurements and calculated soot concentrations along the length of an experimental combustor

Radiometric data were obtained over a range of parametric test conditions at three positions along the length of an experimental combustor segment corresponding to the primary, intermediate, and dilution zones. The concentration of soot entrained in the combustion gases was calculated by a technique using spectral radiance measurements. Tests were conducted primarily with Jet A fuel, although limited data were taken with two fuels having higher aromatic content, diesel oil number 2 and a blend of 40 percent tetralin in Jet A fuel. Radiometric observation of the combustion gases indicated that the maximum total radiance peaked at the intermediate zone, which was located immediately upstream of the dilution holes. Soot concentrations calculated from optical measurements in the dilution zone compared favorably with those obtained by in situ gas sampling at the exhaust. The total radiance increased with the higher aromatic content fuels.

Norgren, C. T.↗

Experimental Investigation of Water Droplet Impingement on Airfoils, Finite Wings, and an S-duct Engine Inlet

Validation of trajectory computer codes, for icing analysis, requires experimental water droplet impingement data for a wide range of aircraft geometries as well as flow and icing conditions. This report presents improved experimental and data reduction methods for obtaining water droplet impingement data and provides a comprehensive water droplet impingement database for a range of test geometries including an MS(1)-0317 airfoil, a GLC-305 airfoil, an NACA 65(sub 2)-415 airfoil, a commercial transport tail section, a 36-inch chord natural laminar flow NLF(1)-0414 airfoil, a 48-inch NLF(1)-0414 section with a 25 percent chord simple flap, a state-of-the-art three-element high lift system, a NACA 64A008 finite span swept business jet tail, a full-scale business jet horizontal tail section, a 25 percent-scale business jet empennage, and an S-duct turboprop engine inlet. The experimental results were obtained at the NASA Glenn Icing Research Tunnel (IRT) for spray clouds with median volumetric diameter (MVD) of 11, 11.5, 21, 92, and 94 microns and for a range of angles of attack. The majority of the impingement experiments were conducted at an air speed of 175 mph corresponding to a Reynolds number of approximately 1.6 million per foot. The maximum difference of repeated tests from the average ranged from 0.24 to 12 percent for most of the experimental results presented. This represents a significant improvement in test repeatability compared to previous experimental studies. The increase in test repeatability was attributed to improvements made to the experimental and data reduction methods. Computations performed with the LEWICE-2D and LEWICE-3D computer codes for all test configurations are presented in this report. For the test cases involving median volumetric diameters of 11 and 21 microns, the correlation between the analytical and experimental impingement efficiency distributions was good. For the median volumetric diameters of 92 and 94-micron cases, however, the analysis produced higher impingement efficiencies and larger impingement limits than the experiment. It is speculated that this discrepancy is due to droplet splashing and breakup experienced by large droplets during impingement.

Papadakis, Michael↗

Supersonic Retropropulsion Experimental Results from the NASA Langley Unitary Plan Wind Tunnel

A new supersonic retropropulsion experimental effort, intended to provide code validation data, was recently completed in the Langley Research Center Unitary Plan Wind Tunnel Test Section 2 over the Mach number range from 2.4 to 4.6. The experimental model was designed using insights gained from pre-test computations, which were instrumental for sizing and refining the model to minimize tunnel wall interference and internal flow separation concerns. A 5-in diameter 70-deg sphere-cone forebody with a roughly 10-in long cylindrical aftbody was the baseline configuration selected for this study. The forebody was designed to accommodate up to four 4:1 area ratio supersonic nozzles. Primary measurements for this model were a large number of surface pressures on the forebody and aftbody. Supplemental data included high-speed Schlieren video and internal pressures and temperatures. The run matrix was developed to allow for the quantification of various sources of experimental uncertainty, such as random errors due to run-to-run variations and bias errors due to flow field or model misalignments. Preliminary results and observations from the test are presented, while detailed data and uncertainty analyses are ongoing.

Berry, Scott A.↗

DataComm in Flight Deck Surface Trajectory-Based Operations

The purpose of this pilot-in-the-loop aircraft taxi simulation was to evaluate a NextGen concept for surface trajectory-based operations (STBO) in which air traffic control (ATC) issued taxi clearances with a required time of arrival (RTA) by Data Communications (DataComm). Flight deck avionics, driven by an error-nulling algorithm, displayed the speed needed to meet the RTA. To ensure robustness of the algorithm, the ability of 10 two-pilot crews to meet the RTA was tested in nine experimental trials representing a range of realistic conditions including a taxi route change, an RTA change, a departure clearance change, and a crossing traffic hold scenario. In some trials, these DataComm taxi clearances or clearance modifications were accompanied by preview information, in which the airport map display showed a preview of the proposed route changes, including the necessary speed to meet the RTA. Overall, the results of this study show that with the aid of the RTA speed algorithm, pilots were able to meet their RTAs with very little time error in all of the robustness-testing scenarios. Results indicated that when taxi clearance changes were issued by DataComm only, pilots required longer notification distances than with voice communication. However, when the DataComm was accompanied by graphical preview, the notification distance required by pilots was equivalent to that for voice.

Bakowski, Deborah L.↗

DataComm in Flight Deck Surface Trajectory-Based Operations

The purpose of this pilot-in-the-loop aircraft taxi simulation was to evaluate a NextGen concept for surface trajectory-based operations (STBO) in which air traffic control (ATC) issued taxi clearances with a required time of arrival (RTA) by Data Communications (DataComm). Flight deck avionics, driven by an error-nulling algorithm, displayed the speed needed to meet the RTA. To ensure robustness of the algorithm, the ability of 10 two-pilot crews to meet the RTA was tested in nine experimental trials representing a range of realistic conditions including a taxi route change, an RTA change, a departure clearance change, and a crossing traffic hold scenario. In some trials, these DataComm taxi clearances or clearance modifications were accompanied by 'preview' information, in which the airport map display showed a preview of the proposed route changes, including the necessary speed to meet the RTA. Overall, the results of this study show that with the aid of the RTA speed algorithm, pilots were able to meet their RTAs with very little time error in all of the robustness-testing scenarios. Results indicated that when taxi clearance changes were issued by DataComm only, pilots required longer notification distances than with voice communication. However, when the DataComm was accompanied by graphical preview, the notification distance required by pilots was equivalent to that for voice.

NextGen↗

Experimental validation of simplified radionuclide transport bubble scrubbing code in sodium coolant pool

Solid radionuclides released following fuel pin failure may become entrained in gaseous fission products and be rapidly transported through the coolant pool to the cover gas region. Sensitivity studies on radionuclide transport have identified this potential pathway as one of both high concern and high uncertainty. The simplified radionuclide transport scrubbing code utilizes classical aerosol scrubbing mechanisms to model this phenomenon and predict aerosol masses reaching the cover gas region. This paper serves to validate this code in a sodium environment while conducting a parametric study to analyze the effects of aerosol size, bubble size, pool temperature, pool depth, aerosol density, and aerosol concentration. Through a series of experimental tests, it was determined that aerosol sizes ranging from 0.001 to 1.0 µm are of primary concern as aerosols in this range have a ratio of aerosol mass entering the sodium pool from the fuel pin to aerosol mass exiting the sodium pool to the cover gas region of less than 10. Further, the experimental results were found to match the trends found in the scrubbing model closely, but significantly more scrubbing was seen experimentally. Decreasing bubble size and increasing pool depth and aerosol density were all found to increase scrubbing both experimentally and theoretically. Pool temperature was found to have a negligible effect on scrubbing amounts; however, this was largely due to a subsequent increase in bubble size corresponding to increasing temperatures which offset the increase in scrubbing due to increased temperature. Varying aerosol concentration was found to have no effect on scrubbing ratios. A final series of tests was conducted for a more prototypic fuel pin failure with a heterogenous bubble swarm. From these tests, it was found that the experimental scrubbing quantities were larger than for the single bubble case. Overall, it was found that the simplified bubble transport scrubbing code accurately models the trends of the bubble scrubbing but provides a conservative estimate of scrubbing quantities. Model limitations fail to model the complex phenomena present for fission product scrubbing via bubble transport, but match trends seen experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing in Support of the Development of EPP Plus SMT Design Method at ORNL (FY2021)

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY21. This report focuses on the methodology for developing the EPP+SMT creep-fatigue (CF) design curves at low strain ranges. The creep damage-based method and dissipated work-based method were used to evaluate the available CF data at the low strain range region. A set of failure criteria were determined, and a simple extrapolation method was developed to predict the CF life cycles at low strain ranges that are not accessible by experiments due to the extraordinarily long failure times at the low strain region (thousands to hundreds of thousands of years) and the inability of the test machine to control these small strain ranges due to the signal to noise issues. An experimental method with the concept of block-strain range CF testing was proposed to generate the information needed to extrapolate the CF design curves to low strain ranges. Based on this new testing approach, a preliminary EPP+SMT CF design curve was developed for Alloy 617 at 950°C with tension hold time of 100 s. The analysis in this report shows the potential of generating a set of EPP+SMT CF design curves with different hold times within a reasonable amount of time and testing effort. Based on such a progress, a hold time extrapolation procedure for low strain ranges will be developed in FY22 and critical testing will be carried out to complete the development of the EPP+SMT CF design curves for Alloy 617.

36 MATERIALS SCIENCE↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hypervelocity impact on shielded plates

A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

Smith, James P.↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Experiments towards a neutron target for measurements in inverse kinematics

Neutron-induced reactions play an important role in fundamental nuclear physics, nuclear astrophysics, and applications. In the case of reactions on rare isotopes, there are limited options for direct experimental measurements. The Neutron Target Demonstrator project at Los Alamos National Laboratory seeks to test the feasibility of moderating spallation neutrons within a 1 m 3 graphite cube to create a standing neutron target for neutron-induced reaction measurements in inverse kinematics. This paper presents the results of experimental neutron flux distribution tests using neutron sources (ranging from 1 keV to 50 MeV) created by accelerators at the University of Notre Dame and Texas A&M University. Measurements were made with both the full graphite cube as well as a ”half cube” setup in which half of the graphite cube was removed. The measured distributions agree with simulated distributions in the case of the full cube moderator, although there remain discrepancies in certain cases for the half cube moderator. The results shown here will provide useful information for an upcoming experimental campaign to test the neutron target proof-of-principle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

Dolan, F. X.↗

Scaling of impact damage in fiber composites

Impact damage in fiber composite structures remains of much concern, and is often the limiting factor in establishing allowable strain levels. The complexity of impact damage formation usually dictates that experiments are required, but scaling of results from small laboratory scale specimens to large structures introduces additional uncertainty into the analysis. This presentation gives the results of an analytical and experimental investigation intended to develop procedures for prediction of damage formation and subsequent strength loss, with particular emphasis on scaling of results with respect to structure size. The experimental investigation involved both drop-weight and airgun impact on carbon/epoxy plates and cylinders. Five sizes of plates ranging from 50 by 50 by 1.072 mm to 250 by 250 by 5.36 mm, and two sizes of cylinders with diameters of 96.5 and 319 mm, were employed in the experimental program. Impact tests were carried out over a range of impact conditions, and specimens were inspected for damage by C-scan and deplying. Analysis procedures were developed for both quasistatic and dynamic impacts for both the plates and cylinders. As has been reported previously, comparison of predicted structural response and measured surface strains was quite good over the entire range of sizes employed in the program. The damage formation and strength loss after impact showed a number of interesting features that are significant with respect to scaling of size. The extent of delamination was observed to increase with specimen size more than would be expected if stresses controlled the delamination extent. This was explained on the basis that delamination is controlled by energy release rates, and thus incorporates the usual dependence on the absolute size characteristic of fracture mechanics. Additionally, the experiments indicated that delamination initiated at matrix cracks and is dependent on the absolute size of the ply group thicknesses. Both the initiation and propagation of delamination are seen to be controlled by fracture mechanics parameters, and thus show specific dependence on size that must be accounted for in extrapolating results from laboratory scale tests to full size structures.

Swanson, Stephen R.↗

Measurements of reactive gaseous rocket injector admittances

The paper describes the results of an experimental study of the quantitative determination of the capabilities of the combustion processes associated with coaxial gaseous propellant rocket injectors to drive combustor pressure oscillations. The data, obtained by employing the modified impedance tube technique with compressed air as the oxidizer and acetylene gas as the fuel, describe the frequency dependence of the admittance of the combined injector-combustion process. The measured data are compared with the predictions of the Feiler and Heidmann analytical model utilizing different values for the characteristic combustion time tau sub b. The values of tau sub b which result in a best fit between the measured and predicted data are indicated for different equivalence ratios. It is shown that for the coaxial injector investigated in this study the tau sub b varies between 0.7 and 1.2 msec for equivalence ratios in the range of 0.57 to 1.31. In addition, the experimental data indicate that the tested injector system could drive combustion instabilities over a frequency range that is in qualitative agreement with the predictions of the Feiler and Heidmann model.

Janardan, B. A.↗

Experimental Surface Pressure Data Obtained on 65 deg Delta Wing Across Reynolds Number and Mach Number Ranges: Sharp Leading Edge - Volume 1

An experimental wind tunnel test of a 65 deg delta wing model with interchangeable leading edges was conducted in the Langley National Transonic Facility (NTF). The objective was to investigate the effects of Reynolds and Mach numbers on slender-wing leading-edge vortex flows with four values of wing leading-edge bluntness. Experimentally obtained pressure data are presented without analysis in tabulated and graphical formats across a Reynolds number range of 6 x 10(exp 6) to 36 x 10(exp 6) at a Mach number of 0.85 and across a Mach number range of 0.4 to 0.9 at a Reynolds number of 6 x 10(exp 6). Normal-force and pitching-moment coefficient plots for these Reynolds number and Mach number ranges are also presented.

Chu, Julio↗

Measurements of reactive gaseous rocket injector response factors

The results presented represent the first successful attempt at the measurement of the driving capabilities of coaxial gaseous propellant rocket injectors. The required data have been obtained by employing the modified impedance tube technique with compressed air as the oxidizer and acetylene gas as the fuel. The data describe the frequency dependence of the injector admittances, from which the frequency dependence of the injection response factors can be calculated. The measured injector admittances have been compared with the predictions of the Feiler and Heidmann (1967) analytical model assuming different values for the characteristic combustion time. The values of combustion time which result in a best fit between the measured and predicted data are indicated for different equivalence ratios. It is shown that for the coaxial injector system investigated in this study the characteristic combustion times vary between .7 and 1.2 msec for equivalence ratios in the range of .57 to 1.31. The experimental data clearly show that the tested injector system could indeed drive combustion instabilities over a frequency range that is in qualitative agreement with the predictions of the Feiler and Heidmann model.

Janardan, B. A.↗