Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers

This paper describes the design and experimental tests of a novel neutron spin analyzer optimized for wide angle spin echo spectrometers. The new design is based on nonremanent magnetic supermirrors, which are magnetized by vertical magnetic fields created by NdFeB high field permanent magnets. The solution presented here gives stable performance at moderate costs in contrast to designs invoking remanent supermirrors. In the experimental part of this paper we demonstrate that the new design performs well in terms of polarization, transmission, and that high quality neutron spin echo spectra can be measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Report on Rare Plant Monitoring and Restoration at the Lawrence Livermore National Laboratory's Experimental Test Site (Site 300) 2015 through 2017

This report describes rare plant monitoring and restoration activities conducted at Lawrence Livermore National Laboratory’s (LLNL) Experimental Test Site (Site 300) in 2015, 2016, and 2017. Section A describes monitoring and field activities conducted at Site 300 native and experimental populations and the Carnegie Canyon native population of the State and federally-endangered plant, Amsinckia grandiflora (the large - flowered fiddleneck) .

54 ENVIRONMENTAL SCIENCES↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Multi-Column Experimental Test Bed for Xe/Kr Separation

Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both tests. The effluent from the AgZ-PAN column was monitored via GC-TCD during the tests with no xenon being observed exiting the column during either test. Samples from each column were taken via evacuated sample bombs and were analyzed by GC-MS analysis. The results demonstrated the ability to separate xenon from krypton from a mixed gas feed utilizing the new multi-column system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bat Survey for the Lawrence Livermore National Laboratory Experimental Test Site 300

Pursuant to Subcontract Number B644180 between ECORP Consulting, Inc. (ECORP) and Lawrence Livermore National Security, LLC. at Lawrence Livermore National Laboratory (LLNL), ECORP conducted focused bat surveys at LLNL’s Experimental Test Site (Site 300) during the spring of 2021. The surveys targeted two focal species including the Western red bat (Lasiurus blossevillii) and pallid bat (Antrozous pallidus) on the approximately 6,800-acre Site 300 in Alameda and San Joaquin Counties. The results of these surveys will provide supporting information for a Site-Wide Environmental Impact Statement.

54 ENVIRONMENTAL SCIENCES↗

Experimental Test of Instability-Enhanced Collisional Friction for Determining Ion Loss in Two Ion Species Plasmas

Recent experiments have shown that ions in weakly collisional plasmas containing two ion species of comparable densities nearly reach a common velocity at the sheath edge. A new theory suggests that collisional friction between the two ion species enhanced by two stream instability reduces the drift velocity of each ion species relative to each other near the sheath edge and finds that the difference in velocities at the sheath edge depends on the relative concentrations of the species. It is small when the concentrations are comparable and is large, with each species reaching its own Bohm velocity, when the relative concentration differences are large. To test these findings, ion drift velocities were measured with laser-induced fluorescence in argon-xenon plasmas. We show that the predictions are in excellent agreement with the first experimental tests of the new model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

First Experimental Test of the Ratio Method

The ratio is a new reaction observable suggested to extract accurately structure information on halo nuclei. It corresponds to the ratio of differential cross sections for scattering and breakup, which is predicted to remove the uncertainty related to the reaction dynamics. We present here the first experimental test of the method for the 11 Be + 12 C collision at E Lab = 20A MeV performed at Texas A&M University. Differential cross sections for scattering and inclusive one-neutron breakup have been measured with the new detector array BlueSTEAl. The ratio of cross sections is very smooth and independent of the projectile-target interaction, which demonstrates the validity of the ratio method. We extend our analysis to existing 11 Be + 208 Pb data, confirming that the method works well on any target.

11Be↗

Lawrence Livermore National Laboratory Experimental Test Site, Site 300: Soil Study Institutional Review Board #1081 Soil Sampling and Analysis Plan

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Functional Area/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) to collect soil quality data at an area located at Lawrence Livermore National Laboratory’s (LLNL’s) Experimental Test Site, Site 300 (Site 300) (project) (Figures 1 and 2). The purpose of the project is to determine the chemical and radiological quality of soil in the project area to support feasibility and design of future improvements. This SAP identifies chemicals of concern and describes the procedures for collection and analysis of environmental samples, and evaluation of analytical data (chemical and radiological) to determine the reuse potential of shallow soil at the project area. This SAP follows the criteria established in LLNL’s Soils Screening and Management Plan (SSMP) (LLNL 2022), which is consistent with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006) and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance (U.S. NRC, U.S. EPA, U.S. DOE, U.S. DOD 2000). The scope of this SAP is based on preliminary design information provided by PMO.

54 ENVIRONMENTAL SCIENCES↗

Experimental Tests of a Real Building Seismically Retrofitted by Special Buckling-Restrained Braces

Buckling Restrained Braces (BRBs), differently from conventional braces, do not exhibit appreciable difference between the tensile and compression capacity and no strength degradation of brace capacity under compressive and cyclic loading. Since lateral and local buckling behaviour modes are restrained, large inelastic capacities are attainable. Hence, BRBs may represent an efficient and reliable solution for reducing the seismic vulnerability of buildings. Results of experimental tests on the response of a real two-story reinforced concrete (RC) building equipped with BRBs are presented and discussed. The considered BRBs are a special 'only-steel' version of the more common 'unbonded braces'. In particular, two different BRBs have been tested. Both of them are detachable 'only-steel' devices, consisting in a rectangular steel plate and a restraining steel sleeve. The latter is composed by two omega shapes which are bolted together. The main characteristic of the braces consists in the possibility to hide them within the space between the facing and the backing of masonry infill walls commonly used for RC buildings.

58 GEOSCIENCES↗

Statistically Significant Evidence of a Release of Zinc from Pit 1 at the Lawrence Livermore National Laboratory Experimental Test Site 300 (90-Day Report)

Lawrence Livermore National Laboratory (LLNL) is submitting this 90-Day Report in accordance with Waste Discharge Requirements Order No. 93-100, Provision 4. This letter report is provided in reference to several seven-day letters in which LLNL reported that ground water sample analytical results from monitoring wells Kl-05, Kl-08, Kl-09, and W-PITl-2326 indicated "statistically significant evidence of a release" of zinc from LLNL's Site 300 Experimental Test Facility landfillPit 1 (Figure 1).

54 ENVIRONMENTAL SCIENCES↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300 should be considered separately when deciding on an approach for reducing the salt discharge to the subsurface. The smaller units may justify moderate changes to equipment, and may benefit from increased cleaning frequencies, more accurate and suitable chemical treatment, and sources of make up water and discharge re-use. The larger cooling towers would be more suitable for automated systems where they don't already exist, re-circulation and treatment of blow down water, and enhanced chemical dosing strategies. It may be more technically feasible and cost efficient for the smaller cooling towers to be replaced by closed loop dry coolers or hybrid towers. There are several potential steps that could be taken at each location to reduce the TDS concentration and/or water use. These include: sump water filtration, minimization of drift, accurate chemical dosing, and use of scale and corrosion coupons for chemical calibration. The implementation of some of these options could be achieved by a step-wise approach taken at two representative facilities. Once viable prototype systems have been proven in the field, systematic implementation should proceed for the remaining systems, with cost, desired reduction, and general feasibility taken into consideration for such systems.

54 ENVIRONMENTAL SCIENCES↗

Analysis and Experimental Testing of a New Type of Variable Stiffness Magnetic Spring with a Linear Stroke Length

In this paper a new type of variable stiffness magnetic spring is proposed. The magnetic spring is composed of radially magnetized outer rotor magnets coupled with axially magnetized inner cylindrical magnets. It is shown that this magnet arrangement creates a highly linear stroke length. By rotating the inner magnetic rotor, the stiffness of the spring can be adjusted. The force as a function of stroke length and torque required to adjust the stiffness were computed using finite element analysis and then verified using an experimental test setup.

16 TIDAL AND WAVE POWER↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

Electromagnetic analysis and experimental testing of a flux focusing wind turbine magnetic gearbox

The electromagnetic design of the second stage of a 59:1 multistage magnetic gearbox for a wind turbine demonstrator is presented here. The multistage series connected magnetic gearbox is composed of a 6.45:1 first stage and 9.14:1 second stage magnetic gear. The magnetic gears utilize a flux focusing spoke type rotor typology with a unique segmented fully laminated design. The electromagnetic impact of structural design changes on the second stage gearbox is considered with respect to torque density. Severe 3-D edge effects were encountered that greatly reduced the expect torque density of the stage 2 magnetic gear. Experimental testing of the multistage magnetic gear highlight unexpected problems associated with eddy current loss and torque ripple.

17 WIND ENERGY↗