Search NASA⌕ Search

SEARCH · Search NASA

Results for “FABRY-PEROT SPECTROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hinge spectrometer - A grating Fabry-Perot instrument for far-infrared/submillimeter spectroscopy in space

A compact submillimeter spectrometer can be constructed through the use of a combination of grating and Fabry-Perot techniques. The instrument has only one moving part, a grating that pivots about an accurately placed hinge. The entire optical train is cooled to liquid helium temperature for low-background low-noise operation and is designed for use in astronomical observations from aircraft, balloons, or space vehicles. Resolving power R about 20,000 at about 150 microns is demonstrated.

Harwit, Martin↗

Observations of the plasma torus of Jupiter with a Fabry-Perot/charge-coupled device /CCD/ imaging spectrometer

A description is presented of the use of a CCD imaging spectrometer which has been employed at a 2.1 m telescope to obtain monochromatic images in the red and near infrared. The system studied was Jupiter's plasma torus which circles the planet with radial extent about 5 RJ and 7 RJ (RJ is the radius of Jupiter). In ground based measurements the torus has been observed in the forbidden emission lines of S(plus) at 6716 A and 6731 A and S(plus plus) at 9531 A. Attention is given to aspects of instrumentation, observations, and performance. It is felt that the particular significance of the obtained results from the instrumental point of view is the demonstration that the CCD is an excellent detector for monochromatic imaging in the near infrared out to at least 10830 A and that pixel binning before readout can produce significantly improved S/N ratios for the study of faint, diffuse sources in cases where readout noise is dominant.

Roesler, F. L.↗

Enhanced acetylene emission near the north pole of Jupiter

The present paper is concerned with observations of acetylene fundamental and hot band vibrational emission lines from the planet Jupiter. It is pointed out that the observation of a polar bright spot in the atmosphere of Jupiter is characterized by an enhancement in the individual lines of C2H2 which can be interpreted as an enhancement in the acetylene abundance. However, a purely thermal effect, or non-LTE phenomena cannot be excluded. The intensity of the observed hot band lines is also consistent with either hypothesis. The reported observations were performed with a cooled Fabry-Perot Grating Spectrometer (FPGS). Observations and instrumentation are considered in detail along with the calculation of synthetic spectra on the basis of a line-by-line computation, and the interpretation of the obtained data.

Drossart, P.↗

Enhanced acetylene emission near the north pole of Jupiter

The present paper is concerned with observations of acetylene fundamental and hot band vibrational emission lines from the planet Jupiter. It is pointed out that the observation of a polar bright spot in the atmosphere of Jupiter is characterized by an enhancement in the individual lines of C2H2 which can be interpreted as an enhancement in the acetylene abundance. However, a purely thermal effect, on non-LTE phenomena cannot be excluded. The intensity of the observed hot band lines is also consistent with either hypothesis. The reported observations were performed with a cooled Fabry-Perot Grating Spectrometer (FPGS). Observations and instrumentation are considered in detail along with the calculation of synthetic spectra on the basis of a line-by-line computation, and the interpretation of the obtained data.

Drossart, Pierre↗

CCD camera system for cometary research

The objective is to upgrade the NASA/GSFC 36 inch telescope instrumentation, primarily with a new charge coupled device (CCD) camera system, to permit an effective monitoring program of cometary activity by means of narrowband imaging and spectroscopic techniques. Researchers have twice taken delivery of the CCD camera system from Princeton Scientific Instruments and twice returned it within six weeks for repair. During the times they had the camera system in the lab, they measured the instrumental performance of the TEK 512 x 512 CCD chip (e.g., readout noise, dark current, etc) and developed the complete operational software for the camera system plus several useful observing and data reduction routines for use at the telescope. The CCD camera system is controlled by an IBM-AT computer. The peripheral equipment and software to permit the efficient transfer of large amounts of data to the LASP's computers (VAXs) and subsequent timely reductions are also in place. The Io torus (S II) emission was monitored with a Fabry-Perot scanning spectrometer, in conjunction with the International Jupiter Watch. The CCD camera system will be coupled to a narrowband interference filter imager and a long-slit spectrograph to provide regular and well-calibrated spatial and spectral observations of comets.

Oliversen, R. J.↗

O I (7990 A) emission and radiative entrapment of auroral EUV

The auroral O I 7990-A multiplet intensity distribution has been observed by means of a 2-m grille spectrometer and a Fabry-Perot interferometer during 1977 and 1982, respectively, in Alaska. Grille spectrometer results indicate a nonstatistical distribution in the excited state, consistent with the preferential scattering of the O I 989-A EUV emission and in accord with recent radiative transfer calculations. A comparison of O I 7990-A intensities measured on the nightside with those from dayside magnetospheric cleft aurora shows a cascade contribution to the O I 8446-A line, and ultimately to the O I 1304-A transition, that depends on the altitude of the aurora. This is attributed to the greater radiative enhancement of O I 989-A at low altitude, and the correspondingly enhanced probability for branching from the 3 s-prime to the 3 p level in atomic O.

Christensen, A. B.↗

Infrared instrumentation on NASA airborne observatories

Two airborne observatories operated above much of the earth's atmosphere are providing effective platforms for infrared astronomical observations. A summary is given of the wide variety of instrumentation currently in use and continuing to be developed for these facilities. The classes of instruments include various far infrared photometers, filter wheel and grating spectrometers, Fourier transform spectrometers, Michelson and Fabry-Perot interferometers, a polarimeter, and a microwave line receiver.

Boggess, N. W.↗

Wave motions in the upper atmospheric sodium layer observed with a lidar technique

Since the middle of 1980, the vertical profile of the atmospheric sodium layer was observed with a tunable laser radar at Mt. Zao Observatory in northern Japan. The principal characteristics of the lidar system are summarized. The output wavelength is continuously monitored by using a sodium resonance cell, a spectrometer, and a Fabry-Perot interferometer provided with the reference spectrum of the sodium lamp. Owing to the strict temperature control of the filters, the tuning is sufficiently stable throughout the night. The calibration of the absolute sodium density was carried out by adopting the method established by previous works.

Kamiyama, H.↗

Thermosphere zonal winds - Vertical motions and temperature as measured from Dynamics Explorer

Dynamics Explorer 2 has made possible, for the first time, global extent in situ measurements of upper thermosphere neutral particle winds. Zonal and vertical wind components, and the kinetic temperature, are being measured by the Wind and Temperature Spectrometer (WATS), while the Fabry-Perot Interferometer provides the meridional component. The present investigation is concerned with the zonal wind component, the vertical motions, and the temperature measured by the WATS. Preliminary studies of the neutral zonal wind components conducted for many orbits confirm a global pattern of upper thermosphere winds which blow over the earth from the mid-afternoon sector. Velocities range from near zero to a few hundred meters per second. Major perturbations to the basic thermally driven wind patterns are observed in both polar regions where the directions are frequently reversed and where the zonal velocities sometimes exceed 1 km/sec.

Spencer, N. W.↗

Circulation of the polar thermosphere during geomagnetically quiet and active times as observed by Dynamics Explorer 2

The effects of geomagnetic activity on the circulation of the high-latitude neutral thermosphere were studied for the periods of November 1981 through January 1982 and November 1982 through January 1983, using neutral wind measurements obtained by the Fabry-Perot interferometer and the wind and temperature spectrometer on the Dynamics Explorer 2. Results for the Northern Hemisphere show evidence of two-cell circulation of the thermosphere at high latitudes during both quiet and active geomagnetic periods at solar maximum; the dusk cell was always dominant. In the Southern Hemisphere, only a single circulation cell existed for both quiet and active periods associated with the dusk cell of ionospheric convection. In both hemispheres, the cell sizes decreased when geomagnetic activity was reduced.

Mccormac, F. G.↗

Observations of the dynamics of the polar thermosphere

The dynamics of the polar thermosphere are examined by using observations made from the Dynamics Explorer 2 satellite. The results used in this study were obtained primarily from the Fabry-Perot interferometer (FPI) and the wind and temperature spectrometer (WATS) during the time period from September 1981 through January 1982. Two primary geophysical conditions were examined: these were the southern summer and the northern winter polar regions. The results support the conclusion that above 60 degrees of latitude the neutral winds are strongly controlled by ion/neutral frictional momentum transfer resulting from magnetospheric convection. This implies that the natural coordinate system within which to display the neutral winds in the high polar thermosphere is magnetic. The collected observations of this study were used to assess the validity of two of the large thermospheric general circulation models. The result of this assessment was that the models reasonably represent the vector winds at high altitudes but do not, at present, accurately simulate the thermodynamics of that regime.

Hays, P. B.↗

Far-infrared spectroscopy of the earth's stratosphere

This paper discusses the spectrum of the earth's stratosphere in the far-infrared, from 5 to 250/cm. Many of the trace gases that are important in stratospheric photochemistry have been measured, or are potentially measurable in the far-infrared. The spectral features of these gases are discussed with application to spacecraft measurements. In particular, the suitability of the spectrum for measurements of the HO(x) and ClO(x) families and of O3 are compared for different classes of instruments: Fourier transform spectrometers, filter radiometers, and scanning high-resolution Fabry-Perot instruments. It is found that these types of instruments have complementary capabilities that would best be used in combination in a comprehensive multispecies measurement scheme.

Chance, K. V.↗

The radial velocity search for extrasolar planets

Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.

Mcmillen, R. S.↗

Planetary Fabry-Perot spectroscopy

Uranus and Jupiter HD/H2 spectra determine bulk D/H ratios which are significantly different from theoretical expectations, with the Uranus D/H about half the Jovian value. Feasibility of Mars photochemistry study with a PEPSIOS spectrometer was demonstrated with visible band O2, H2O, and CO2 spectra; and near infrared (1.57 micron) spectra of CO and CO2; and NASA/IRTF observations have been proposed in support of the Mars Observer mission objectives. Analysis of monochromatic images clearly resolve the azimuthal and radial structure in the Jovian nebula (ion partitioning, temperature structure, ion/neutral interactions), adding a unique and important post-Voyager perspective and providing a baseline for forthcoming Galileo experiments. Simultaneous ground based and IUE observations of Jovian nebula are under analysis. Doppler resolved image sequences (data cubes) of Io sodium neutrals clearly isolate the high velocity charge exchange jet, a sensitive ground-based probe of the tenuous neutral atmosphere of Io.

Trauger, J. T.↗

Investigation of thermospheric winds relative to space station orbital altitudes

An investigation of thermospheric winds, relative to the space station orbital altitudes, was made in order to provide information that is useful in an environmental disturbance assessment. Current plans are for this low Earth orbiting facility to orbit at an inclination of 28.5 deg. The orbital altitudes were not yet defined due to the evolutionary configuration of the Space Station. The upper and lower bounds of the orbital altitudes will be based on constraints set by the drag and expected orbital decay and delivery altitude capability of the Shuttle. The orbital altitude will be estimated on the order of 500 km. Neutral winds in the region from about 80 to 600 km which were derived from satellite drag data, Fabry-Perot interferometers, sounding rockets, ground-based optical Doppler techniques, incoherent scatter radar measurements from Millstone Hill combined with the mass spectrometer and lithium trail neutral wind measurements are examined. The equations of motion of the low Earth orbiting facility are also discussed.

Susko, M.↗

Neutral winds in the polar thermosphere as measured from Dynamics Explorer

Remote sensing measurements of the meridional thermospheric neutral wind using the Fabry-Perot Interferometer on Dynamics Explorer have been combined with in-situ measurements of the zonal component using the Wind and Temperature Spectrometer on the same spacecraft. The two data sets with appropriate spatial phasing and averaging determine the vector wind along the track of the polar orbiting spacecraft. A study of fifty-eight passes over the Southern (sunlit) pole has enabled the average Universal Time dependence of the wind field to be determined for essentially a single solar local time cut. The results show the presence of a 'back-ground' wind field driven by solar EUV heating upon which is superposed a circulating wind field driven by high latitude momentum and energy sources.

Killeen, T. L.↗

The LPL radial accelerometer

The LPL stellar accelerometer, an interferometrically calibrated spectrometer, is described. Particular attention is given to light feed, image scrambling, and interferometric wavelength calibration. Changes in radial velocity are inferred from changes in the relative intensities of starlight transmitted through the Fabry-Perot.

Mcmillan, R. S.↗

Search for planets by spectroscopic methods

Spectroscopic means of detecting the motion of a star around a star-planet barycenter are considered. The precision of such an observation, which requires a radial velocity error of not more than 5 m/sec, is discussed in relation to the spectral resolutions of the detectors utilized. The University of Arizona radial velocity spectrometer is then presented, with particular attention given to the location of the absorption cell in a beam of light from an incandescent bulb, high-accuracy wavelength calibration involving the use of a Fabry-Perot interferometer in front of an echelle spectrograph, and future plans for the use of light reflected from a Fabry-Perot etalon to improve transmittance. On the basis of these techniques, it is expected that radial velocities with accuracies sufficient for the detection of extrasolar planets will be obtained.

Serkowski, K.↗