Strong cube-textured titanium nitride conductive films directly on flexible metal substrate
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Explore the source record for details and available documents.
Integration of renewables-assisted carbon capture with existing fossil power plants is an economical grid decarbonization technique and renewable intermittency solution.
Explore the source record for details and available documents.
When modeling and analyzing the power grid and other large scale systems, researchers often express scenarios as optimization problems and feed them into advanced software solvers. In order to allow multiple solvers to communicate with each other and share data from different domains, the National Renewable Energy Laboratory (NREL) and associated Department of Energy (DOE) labs have developed a software framework called the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). HELICS allows cosimulation via a collection of client libraries for different languages that can be called from the appropriate optimization software. However, these client libraries do not provide a higher level of abstraction beyond reading and writing data off of the shared HELICS bus. In this paper, we describe a new software library called the SEAS Communication Engine that exposes a higher-level API for running cosimulation problems. The SEAS Engine provides a class-based abstraction on top of the Python HELICS client, in order to allow users to implement their domain-specific cosimulations without needing to interact with core HELICS primitives. This will make adoption of HELICS and cosimulation in general easier, by exposing a simpler API. In the second part of the paper, we validate our library on a collection of different simulation examples, including the canonical IEEE 13 Bus Feeder. Lastly, we demonstrate using the SEAS Engine to directly call domain-specific code written in the Julia programming language. Our hope is that this will serve as a template for easily calling software in different programming languages via the SEAS Engine, thereby avoiding code duplication and complexity.
GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.
The renewable energy transition in the power sector involves a paradigm shift for flexibility. Flexible demand is more attainable than before, while supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and avoid need for additional capacity. Industrial flexibility could be especially interesting in this regard, as industrial customers are larger on average than other customers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We then examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. Here, we conclude that in the United States these technological innovation systems are not well-functioning for industry in general or for steel, but do seem to be present for green ammonia. Additionally, explicit connections between scope two greenhouse gas emissions (those from purchased energy) and flexibility are lacking, and likewise industry stakeholders do not appear to make a connection between decarbonization and load flexibility, thus flexible demand is not viewed as a tool in industrial decarbonization.
As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.
The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.
The renewable energy transition in the power sector involves a paradigm shift for flexibility. Supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and delay need for additional capacity and transmission. Industrial customers are larger on average than residential and commercial consumers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. We conclude that the technological innovation systems are not well-functioning for flexibility in EAF based steelmaking, but are in the green ammonia space. Explicit connections between scope two greenhouse gas emissions reporting and flexibility are lacking, and industry stakeholders do not appear to make a connection between decarbonization and load flexibility.
This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.
Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.
Flexible metal–gas batteries have become increasingly attractive for use in wearable electronics in the recent years due to their large theoretical energy density and superior adaptability to irregular geometric surfaces, such as the human body. With continuous improvements in design strategies and assembly technologies, the fabrication of various advanced flexible metal–gas batteries has been attempted. In spite of these efforts, the synchronous integration of high flexibility, safety, comfort, and high performance into flexible metal–gas batteries with specifically functionalized configurations still remains a formidable challenge. To resolve these dilemmas, the redesign of cathode catalysts, gel polymer electrolyte, and battery configurations/components has been investigated. In this paper, we review the recent technical advances together with the major dilemmas facing currently available flexible metal–gas batteries, highlighting how flexible cathodes and gel polymer electrolytes with various structures and components can affect the electrochemical performance and functionality of flexible metal–gas batteries. Flexible Zn–air, Li–O 2 /air, and Li–CO 2 batteries are mainly exemplified to elucidate their promising potential. Finally, based on our considerations, unresolved technical hurdles and future research perspectives involving flexible metal–gas batteries for wearable electronics are proposed.
Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.
Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.