Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW - BODIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Three Dimensional Flow Field at the Exit of an Axial-Flow Turbine Rotor

A systematic and comprehensive investigation was performed to provide detailed data on the three dimensional viscous flow phenomena downstream of a modem turbine rotor and to understand the flow physics such as origin, nature, development of wakes, secondary flow, and leakage flow. The experiment was carried out in the Axial Flow Turbine Research Facility (AFTRF) at Penn State, with velocity measurements taken with a 3-D LDV System. Two radial traverses at 1% and 10% of chord downstream of the rotor have been performed to identify the three-dimensional flow features at the exit of the rotor blade row. Sufficient spatial resolution was maintained to resolve blade wake, secondary flow, and tip leakage flow. The wake deficit is found to be substantial, especially at 1% of chord downstream of the rotor. At this location, negative axial velocity occurs near the tip, suggesting flow separation in the tip clearance region. Turbulence intensities peak in the wake region, and cross- correlations are mainly associated with the velocity gradient of the wake deficit. The radial velocities, both in the wake and in the endwall region, are found to be substantial. Two counter-rotating secondary flows are identified in the blade passage, with one occupying the half span close to the casino and the other occupying the half span close to the hub. The tip leakage flow is well restricted to 10% immersion from the blade tip. There are strong vorticity distributions associated with these secondary flows and tip leakage flow. The passage averaged data are in good agreement with design values.

Lakshminarayana, B.↗

Virtual and Experimental Visualization of Flows in Packed Beds of Spheres Simulating Porous Media Flows

A videotape presentation of flow in a packed bed of spheres is provided. The flow experiment consisted of three principal elements: (1) an oil tunnel 76.2 mm by 76.2 mm in cross section, (2) a packed bed of spheres in regular and irregular arrays, and (3) a flow characterization methodology, either (a) full flow field tracking (FFFT) or (b) computational fluid dynamic (CFD) simulation. The refraction indices of the oil and the test array of spheres were closely matched, and the flow was seeded with aluminum oxide particles. Planar laser light provided a two-dimensional projection of the flow field, and a traverse simulated a three-dimensional image of the entire flow field. Light focusing and reflection rendered the spheres black, permitting visualization of the planar circular interfaces in both the axial and transverse directions. Flows were observed near the wall-sphere interface and within the set of spheres. The CFD model required that a representative section of a packed bed be formed and gridded, enclosing and cutting six spheres so that symmetry conditions could be imposed at all cross-boundaries. Simulations had to be made with the flow direction at right angles to that used in the experiments, however, to take advantage of flow symmetry. Careful attention to detail was required for proper gridding. The flow field was three-dimensional and complex to describe, yet the most prominent finding was flow threads, as computed in the representative 'cube' of spheres with face symmetry and conclusively demonstrated experimentally herein. Random packing and bed voids tended to disrupt the laminar flow, creating vortices.

Hendricks, R. C.↗

Flow Control Device Evaluation for an Internal Flow with an Adverse Pressure Gradient

The effectiveness of several active and passive devices to control flow in an adverse pressure gradient with secondary flows present was evaluated in the 15 Inch Low Speed Tunnel at NASA Langley Research Center. In this study, passive micro vortex generators, micro bumps, and piezoelectric synthetic jets were evaluated for their flow control characteristics using surface static pressures, flow visualization, and 3D Stereo Digital Particle Image Velocimetry. Data also were acquired for synthetic jet actuators in a zero flow environment. It was found that the micro vortex generator is very effective in controlling the flow environment for an adverse pressure gradient, even in the presence of secondary vortical flow. The mechanism by which the control is effected is a re-energization of the boundary layer through flow mixing. The piezoelectric synthetic jet actuators must have sufficient velocity output to produce strong longitudinal vortices if they are to be effective for flow control. The output of these devices in a laboratory or zero flow environment will be different than the output in a flow environment. In this investigation, the output was higher in the flow environment, but the stroke cycle in the flow did not indicate a positive inflow into the synthetic jet.

Jenkins, Luther N.↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Towards Reconstruction of Complex Flow Fields Using Unit Flows

Many complex turbulent flows in nature and engineering can be qualitatively regarded as being constituted of multiple simpler unit flows. The objective of this work is to characterize the coherent structures in such complex flows as a combination of constituent unitary flow structures for the purpose of reduced-order representation. While turbulence is clearly a non-linear phenomenon, we aim to establish the degree to which the optimally weighted superposition of unitary flow structures can represent the complex flow structures. The rationale for investigating such superposition stems from the fact that the large-scale coherent structures are generated by underlying flow instabilities that may be reasonably described using linear analysis. Clearly, the degree of validity of superposition will depend on the flow under consideration. In this work, we take the first step toward establishing a procedure for investigating superposition. Experimental data of single and triple tandem jets in crossflow are used to demonstrate the procedure. A composite triple tandem jet flow field is generated from optimal superposition of single jet data and compared against ‘true’ triple jet data. Direct comparisons between the true and composite fields are made for spatial, temporal, and kinetic energy content. The large-scale features (obtained from proper orthogonal decomposition or POD) of true and composite tandem jet wakes exhibit nearly 70% agreement in terms of modal eigenvector correlation. Corresponding eigenvalues reveal that the kinetic energy of the flow is also emulated with only a slight overprediction. Temporal frequency features are also examined in an effort to completely characterize POD modes. The proposed method serves as a foundation for more rigorous and robust dimensional reduction in complex flows based on unit flow modes.

Kristo, Paul J.↗

Visual study of the effect of grazing flow on the oscillatory flow in a resonator orifice

Grazing flow and oscillatory flow in an orifice were studied in a plexiglass flow channel with a single side branch Helmholtz resonator using water as the fluid medium. An oscillatory flow was applied to the resonatory cavity, and color dyes were injected in both the orifice and the grazing flow field to record the motion of the fluid. The flow regimes associated with linear and nonlinear (high sound pressure level) impedances with and without grazing flows were recorded by a high-speed motion-picture camera. Appreciable differences in the oscillatory flow field were seen in the various flow regimes. With high grazing flows, the outflow and inflow from the resonator cavity are found to be asymmetric. The visual study confirms that jet energy loss during flow into a resonator cavity is much larger than the loss for ejection from the cavity into the grazing flow. For inflow into the resonator cavity, the effective orifice area was significantly reduced.

Baumeister, K. J.↗

Vortex shedding flow meter performance at high flow velocities

In some of the ducts of the Space Shuttle Main Engine (SSME), the maximum liquid oxygen flow velocities approach 10 times those at which liquid flow measurements are normally made. The hydrogen gas flow velocities in other ducts exceed the maximum for gas flow measurement by more than a factor of 3. The results presented here show from water flow tests that vortex shedding flow meters of the appropriate design can measure water flow to velocities in excess of 55 m/s, which is a Reynolds number of about 2 million. Air flow tests have shown that the same meter can measure flow to a Reynolds number of at least 22 million. Vortex shedding meters were installed in two of the SSME ducts and tested with water flow. Narrow spectrum lines were obtained and the meter output frequencies were proportional to flow to + or - 0.5% or better over the test range with no flow conditioning, even though the ducts had multiple bends preceeding the meter location. Meters with the shedding elements only partially spanning the pipe and some meters with ring shaped shedding elements were also tested.

Siegwarth, J. D.↗

Experimental and analytical dynamic flow characteristics of an axial-flow fan from an air cushion landing system model

An investigation was conducted to compare the steady-state and dynamic flow characteristics of an axial-flow fan which had been used previously as the air supply fan for some model air cushion landing system studies. Steady-state flow characteristics were determined in the standard manner by using differential orifice pressures for the flow regime from free flow to zero flow. In this same regime, a correlative technique was established so that fan inlet and outlet pressures could be used to measure dynamic flow as created by a rotating damper. Dynamic tests at damper frequencies up to 5 Hz showed very different flow characteristics when compared with steady-state flow, particularly with respect to peak pressures and the pressure-flow relationship at fan stall and unstall. A generalized, rational mathematical fan model was developed based on physical fan parameters and a steady-state flow characteristic. The model showed good correlation with experimental tests at damper frequencies up to 5 Hz.

Thompson, W. C.↗

Cold Flow Determination of the Internal Flow Environment Around the Submerged TVC Nozzle for the Space Shuttle SRM

A series of subscale cold flow tests was performed to quantify the gas flow characteristics at the aft end of the Space Shuttle Solid Rocket Motor. This information was used to support the analyses of the redesigned nozzle/case joint. A portion of the thermal loads at the joint are due to the circumferential velocities and pressure gradients caused primarily by the gimbaling of the submerged nose TVC nozzle. When the nozzle centerline is vectored with respect to the motor centerline, asymmetries are set up in the flow field under the submerged nozzle and immediately adjacent to the nozzle/case joint. Specific program objectives included: determination of the effects of nozzle gimbal angle and propellant geometry on the circumferential flow field; measurement of the static pressure and gas velocities in the vicinity of the nozzle/case joint; use of scaling laws to apply the subscale cold flow data to the full scale SRM; and generation of data for use in validation of 3-D computational fluid dynamic, CFD, models of the SRM flow field. These tests were conducted in the NASA Marshall Space Flight Center Airflow Facility with a 7.5 percent scale model of the aft segment of the SRM. Static and dynamic pressures were measured in the model to quantify the flow field. Oil flow data was also acquired to obtain qualitative visual descriptions of the flow field. Nozzle gimbal angles of 0, 3.5, and 7 deg were used with propellant grain configurations corresponding to motor burn times of 0, 9, 19, and 114 seconds. This experimental program was successful in generating velocity and pressure gradient data for the flow field around the submerged nose nozzle of the Space Shuttle SRM at various burn times and gimbal angles. The nature of the flow field adjacent to the nozzle/case joint was determined with oil droplet streaks, and the velocity and pressure gradients were quantified with pitot probes and wall static pressure measurements. The data was applied to the full scale SRM thru a scaling analysis and the results compared well with the 3-D computational fluid dynamics computer model.

Whitesides, R. H.↗

Flow Simulation of Solid Rocket Motors: Injection Induced Water-Flow Tests from Porous Media - 1

Prior to selecting a proper porous material for use in simulating the internal port flow of a solid rocket motor (SRM), in cold-flow testing, the flow emerging from porous materials is experimentally investigated. The injection-flow emerging from a porous matrix always exhibits a lumpy velocity profile that is spatially stable and affects the development of the longitudinal port flow. This flow instability, termed pseudoturbulence, is an inherent signature of the porous matrix and is found to generally increase with the wall porosity and with the injection flow rate. Visualization studies further show that the flow from porous walls made from shaving-type material (sintered stainless-steel) exhibits strong recirculation zones that are conspicuously absent in walls made from nodular or spherical material (sintered bronze). Detailed flow visualization observations and hot-film measurements are reported from tests of injection-flow and a coupled cross-flow from different porous wall materials. Based on the experimental data, discussion is provided on the choice of suitable material for SRM model testing while addressing the consequences and shortcomings from such a test.

Ramachandran, N.↗

Effect of Free Stream Turbulence on the Flow-Induced Background Noise of In-Flow Microphones

When making noise measurements of sound sources in flow using microphones immersed in an air stream or wind tunnel, the factor limiting the dynamic range of the measurement is, in many cases, the noise caused by the flow over the microphone. To lower this self-noise, and to protect the microphone diaphragm, an aerodynamic microphone forebody is usually mounted on the tip of the omnidirectional microphone. The microphone probe is then pointed into the wind stream. Even with a microphone forebody, however, the self-noise persists, prompting further research in the area of microphone forebody design for flow-induced self-noise reduction. The magnitude and frequency characteristics of in-flow microphone probe self-noise is dependent upon the exterior shape of the probe and on the level of turbulence in the onset flow, among other things. Several recent studies present new designs for microphone forebodies, some showing the forbodies' self-noise characteristics when used in a given facility. However, these self-noise characteristics may change when the probes are used in different facilities. The present paper will present results of an experimental investigation to determine an empirical relationship between flow turbulence and self-noise levels for several microphone forebody shapes as a function of frequency. As a result, the microphone probe self-noise for these probes will be known as a function of freestream turbulence, and knowing the freestream turbulence spectra for a given facility, the probe self-noise can be predicted. Flow-induced microphone self-noise is believed to be related to the freestream. turbulence by three separate mechanisms. The first mechanism is produced by large scale, as compared to the probe size, turbulence which appears to the probe as a variation in the angle of attack of the freestream. flow. This apparent angle of attack variation causes the pressure along the probe surface to fluctuate, and at the location of the sensor orifice this fluctuating surface pressure is sensed by the diaphragm as noise. The second mechanism is caused by the convection of smaller sized turbulence, on the order of the probe cross-section, which passes nearby or strikes the probe giving rise to a fluctuating pressure at the sensor orifice. And, the third mechanism is related to fine scale turbulence through its effects on boundary layer growth and transition to a turbulent boundary layer. The method for relating the probe self-noise to the freestream turbulence will be based on the method of K. J. Young5 from Boeing, who developed the technique and presented flow noise results for a Bruel & Kjaer Type 0385, 1/4 inch (6.35 mm) nose cone. The experimental set-up used in the present experiment is similar to that of Young and is described in the present paper. Finally, flow noise predictions are made using the empirical correlations. These predictions are then compared with actual flow noise measurements made in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel at NASA Ames Research Center.

Allen, Christopher S.↗

Unsteady Analysis of Turbine Main Flow Coupled with Secondary Air Flow

Two numerical approaches are used to model the interaction between the turbine main gas flow and the wheelspace cavity seal flow. The 3-D, unsteady Reynolds-averaged Navier-Stokes equations are solved with a CFD code based on a structured grid to study the interaction between the turbine main gas flow and the wheelspace cavity seal flow. A CFD code based on an unstructured grid is used to solve detailed flow feature in the cavity seal which has a complex geometry. The numerical results confirm various observations from earlier experimental studies under similar flow conditions. When the flow rate through the rim cavity seal is increased, the ingestion of the main turbine flow into the rim seal area decreases drastically. However, a small amount of main gas flow is ingested to the rim seal area even with very high level of seal flow rate. This is due to the complex nature of 3-D, unsteady flow interaction near the hub of the turbine stage.

Hah, Chunill↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory↗

Robust foil regenerator flow loss and heat transfer tests under oscillating flow condition

A regenerator works as an energy storage component in a Stirling engine. Thus, it is one of the most critical components that makes the Stirling engine highly efficient. Traditionally, the regenerators are made of wire media such as woven screens and random fibers. These wire regenerators experience considerably high flow losses through the regenerator due to the flow separation and the resulting vortices. The high flow losses associated with the flow separation and vortices result in a lower engine efficiency. This research is to test a new robust foil regenerator to investigate its feasibility for free-piston Stirling engine applications. The robust foil regenerator is configured with parallel flow channels and stiffening ribs. Comparing to complex flows patterns in woven screen and random fiber regenerators, the flows in the parallel plates are simple and the flow losses are considerably small, and the heat transfer coefficient is also relatively small. To test the regenerator experimentally, a regenerator test rig was manufactured. To verify the accuracy of the test rig, a woven screen regenerator was made and tested prior to the robust foil regenerator test. The friction factor correlation of the woven screen regenerator shows a good agreement with the published regenerator correlations. The robust foil regenerator tests were conducted under the oscillating flow condition with different Reynolds numbers. The flow losses were measured with dynamic pressure transducers and the friction coefficient was derived from measured pressure drop. The measured temperature difference over the regenerator was used to calculate the heat transfer coefficient and Nusselt number. The figure of merit with two methods of NPH/NTU ratio and j/f ratio was calculated to evaluate the suitability of the robust foil regenerator. The results show that the robust foil regenerator has considerably higher figure of merit and therefore, better performance than other types of regenerator.

42 ENGINEERING↗

Recent Ground-based Test Results for the Closed Loop Two-Phase Flow Chilldown Test Module for Future Integration with the Flow Boiling and Condensation Experiment onboard International Space Station

Effective cryogenic fluid management is important to the success of future manned and unmanned NASA missions, and the transfer line chilldown process is recognized as a key technological challenge. To address this challenge, the Two-phase Flow and Thermal Management Lab (TFTML) at Case Western Reserve University is collaborating with NASA Glenn Research Center to develop, test and deploy a closed loop two-phase flow chilldown test section onboard the International Space Station to be integrated with the current Flow Boiling and Condensation Experiment (FBCE) module. The final results of this project will create the first chilldown process database under pure and sustained microgravity conditions and will significantly advance the understanding of the chilldown process for cryogenic fluid management. In the present work, the ground-based test results of the closed loop SS-316 chilldown test section in a horizontal configuration at varying inlet mass flow rates (3-40 g/s) and inlet liquid subcooling (5-35 0C) are presented. The working fluid is PF-5060 and the chilldown curves captured the entire quenching curve involving the different boiling regimes and temperature transition points viz., film boiling, Leidenfrost/re-wetting point, transition boiling, critical heat flux (CHF), nucleate boiling, onset of nucleate boiling (ONB) and single-phase liquid flow regions, when the test section is pre-heated to around 250 0C. The major findings of the present study are, (i) the bottom part of the test section sees a lower re-wetting temperature due to the horizontal flow configuration, (ii) the re-wetting temperatures are relatively unaffected by inlet liquid mass flow rates though the increase in mass flow rates reduce the chilldown time, and (iii) the re-wetting temperatures decrease with decrease in inlet liquid subcooling. Further, preliminary flow visualization studies in a transparent pyrex test section will also be presented to understand the intricate flow boiling regime transitions during the chilldown process.

ISS↗