Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW REGULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flight Operation of a Pump-Fed Liquid-Hydrogen Fuel System

A pump-fed liquid-hydrogen fuel system was developed and flight tested in a B57 bomber. The aircraft was flown to an altitude of 50,000 feet and a Mach number of 0.75 with JP-4 fuel in both engines. One engine was then switched to hydrogen operation for approximately 11 minutes. The liquid-hydrogen pump used for these flights was a five-cylinder positive-displacement type submerged in the bottom of the hydrogen tank. The hydrogen flow regulator was able to maintain a constant engine speed even though pump speed and discharge pressure oscillated.

David B. Fenn↗

Soldering device Patent

Soldering device particularly suited to making high quality wiring joints for aerospace engineering utilizing capillary attraction to regulate flow of solder

Booth, F. W.↗

Technology for the cities

The activities of an organization for making the technology derived from NASA programs available for use by urban communities are discussed. Examples of technology utilization accomplished by the organization are: (1) self-contained breathing apparatus for firemen, (2) short range communication systems, (3) pavement marking, (4) protective clothing for firemen, (5) underground pipe and conduit locator, and (6) automatic fire hose flow regulator. The manner in which urban problems are identified and the designation of applicable technical developments are described.

Source record↗

The use of hydrogen for aircraft propulsion in view of the fuel crisis

Some factors influencing the technical feasibility of operating a liquid hydrogen-fueled airplane are discussed in light of the projected decrease of fossil fuels. Other sources of energy, such as wind, tidal, solar, and geothermal, are briefly mentioned. In view of projected decreases in available petroleum fuels, interest has been generated in exploiting the potential of liquid hydrogen (LH2) as an aircraft fuel. Cost studies of LH2 production show it to be more expensive than presently used fuels. Regardless of cost considerations, LH2 is viewed as an attractive aircraft fuel because of the potential performance benefits it offers. Accompanying these benefits, however, are many new problems associated with aircraft design and operations; for example, problems related to fuel system design and the handling of LH2 during ground servicing. Some of the factors influencing LH2 fuel tank design, pumping, heat exchange, and flow regulation are discussed.

Weiss, S.↗

The use of hydrogen for aircraft propulsion in view of the fuel crisis.

In view of projected decreases in available petroleum fuels, interest has been generated in exploiting the potential of liquid hydrogen (LH2) as an aircraft fuel. Cost studies of LH2 production show it to be more expensive than presently used fuels. Regardless of cost considerations, LH2 is viewed as an attractive aircraft fuel because of the potential performance benefits it offers. Accompanying these benefits, however, are many new problems associated with aircraft design and operations; for example, problems related to fuel system design and the handling of LH2 during ground servicing. Some of the factors influencing LH2 fuel tank design, pumping, heat exchange, and flow regulation are discussed.

Weiss, S.↗

Fluid infusion system

Development of a fluid infusion system was undertaken in response to a need for an intravenous infusion device operable under conditions of zero-g. The initial design approach, pursued in the construction of the first breadboard instrument, was to regulate the pressure of the motive gas to produce a similar regulated pressure in the infusion liquid. This scheme was not workable because of the varying bag contact area, and a major design iteration was made. A floating sensor plate in the center of the bag pressure plate was made to operate a pressure regulator built into the bellows assembly, effectively making liquid pressure the directly controlled variable. Other design changes were made as experience was gained with the breadboard. Extensive performance tests were conducted on both the breadboard and the prototype device; accurately regulated flows from 6 m1/min to 100 m1/min were achieved. All system functions were shown to operate satisfactorily.

Hammond, J. C.↗

Valve assemblies

Seals and sealing, especially relative to valve designs for O2 systems are investigated. Also considered are high pressure requirements, pressure and flow regulators, and check and relief valves. Valve failure as induced by overstress or abrasion, galling, and ignition of valve parts was detailed.

Source record↗

Low-noise current regulator

Modification of conventional regulator minimizes current drift. Current to be regulated flows through sensing resistor in series with load, producing voltage that is fed into operational amplifier. Other input into amplifier is reference voltage from Zener diode network.

Bunn, J.↗

Preserving Color in Developed Photographic Film

Controlled-atmosphere vault retards fading and deterioration of developed high speed film. Vault with externally controlled valve regulates flow of nitrogen gas from internally mounted tank. Gas purges ambient air from vault through purge valve and maintains vault pressure slightly above ambient.

Hoover, R. B.↗

The 1- to 4-K refrigeration techniques for cooling masers on a beam waveguide antenna

The status of technology is reported for various 1- to 4-K commercially available refrigeration systems capable of producing 1.5-K refrigeration to cool masers and superconducting cavity oscillators on the proposed beam waveguide antenna. The design requirements for the refrigeration system and the cryostat are presented. A continuously operating evaporation refrigerator that uses capillary tubing to provide a continuous, self-regulating flow of helium at approximately 1.5 K has been selected as the first refrigerator design for the beam waveguide antenna.

Johnson, D. L.↗

The effect of flow oscillations on cavity drag

An experimental investigation of flow over an axisymmetric cavity shows that self-sustained, periodic oscillations of the cavity shear layer are associated with low cavity drag. In this low-drag mode the flow regulates itself to fix the mean-shear-layer stagnation point at the downstream corner. Above a critical value of the cavity width-to-depth ratio there is an abrupt and large increase of drag due to the onset of the 'wake mode' of instability. It is also shown by measurement of the momentum balance how the drag of the cavity is related to the state of the shear layer, as defined by the mean momentum transport and the Reynolds stress, and how these are related to the amplifying oscillations in the shear layer. The cavity shear layer is found to be different, in several respects, from a free shear layer.

Gharib, M.↗

Simulation of pressure and temperature responses for the 20 Inch Supersonic Wind Tunnel

A simulation of the pressure and temperature responses of the 20 inch Supersonic Wind Tunnel (SWT) is developed. The simulation models the tunnel system as a set of lumped parameter volumes connected by flow regulating elements such as valves and nozzles. Simulated transient responses of temperature and pressure for the five boundary points of the 20 inch SWT operating map are produced from their respective initial conditions, tunnel operating conditions, heater input power, and valve positions. Upon reaching steady state, a linearized model for each operating point is determined. Both simulated and actual tunnel responses are presented for comparison.

Motter, Mark A.↗

Carbon-monoxide Indicators for Aircraft

Several improvements that have been made on commercially available carbon-monoxide indicators to make them more suitable for aircraft use are described. These improvements include an automatic flow regulator, which permits the use of a simplified instrument on aircraft where a source of suction is available, and a more reliable alarm attachment. A field method for testing instruments on standard samples of carbon monoxide is described. Performance data and instructions in operation and maintenance are given.

Womack, S H J↗

Performance of an All-internal Conical Compression Inlet with Annular Throat Bleed at Mach Number 5.0

An all-internal conical compression inlet with annular bleed at the throat was investigated at Mach 5.0 and zero angle of attack. The minimum contraction ratio of the supersonic diffuser, coincident with a mass-flow ratio of 1.0, was determined to be 0.084 as compared with the isentropic contraction ratio of 0.04 at Mach 5.0. The over-all inlet performance was very sensitive to the amount of annular bleed at the throat because of the extensive boundary layer. For example, the critical recovery varied from 41 percent with 6-percent bleed to 59 percent with 25-percent bleed. Decreasing the spacing between the supersonic and subsonic diffusers increased the critical mass-flow ratio but reduced the range of subcritical mass-flow regulation. A constant-area section was required ahead of the subsonic diffuser in order to obtain reasonable performance. An inlet-engine net-thrust analysis indicated that the optimum performance occurred with from 20- to 25-percent bleed, depending on how the bypassed air was handled.

Stitt, Leonard E.↗

Self-generating oscillating pressure exercise device

An exercise device, especially suitable for zero gravity workouts, has a collapsible chamber which generates negative pressure on the lower portion of a body situated therein. The negative pressure is generated by virtue of leg, hand and shoulder interaction which contracts and expands the chamber about the person and by virtue of air flow regulation by valve action.

Watenpaugh, Donald E.↗

Micromachined Ion Accelerators

Proposed ion accelerators made by micromachining techniques. Advantages include small size and weight, modularity, and compatibility with integrated circuits. Used as sources of ion beams for industrial processes. Ion accelerator of this type combined with integrated electronic control and power circuitry, plus similarly miniaturized valves and other mechanisms for regulating flow of gas used to generate ions - all micromachined on single chip. Provides flexibility for tailoring characteristics of ion sources for specific applications; for example, construct array of many such devices to obtain large ion source or position multiple devices to obtain desired ion-beam pattern in processing chamber.

Brophy, John↗